EN1092法兰标准 EN1092-1 法兰标准 Flanges PN 6 EN 1092-1 Dimensions of PN 6 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing acc...
EN1092法兰标准
EN1092-1 法兰 Flanges PN 6 EN 1092-1 Dimensions of PN 6 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1". Dimensions in mm * Above DN 600 dimension C1 is to be specified by the purchaser. ** For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter. NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. Flanges PN 10 EN 1092-1 Dimensions of PN 10 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1". Dimensions in mm * For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter, NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. Flanges PN 16 EN 1092-1 Dimensions of PN 16 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1". Dimensions in mm * For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter, ** 8 holes is preferred however 4 holes may be supplied upon special request by the purchaser. NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. Flanges PN 25 EN 1092-1 Dimensions of PN 25 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1". Dimensions in mm * For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter. NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. Flanges PN 40 EN 1092-1 Dimensions of PN 40 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1". Dimensions in mm * For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter, NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. Flanges PN 63 EN 1092-1 Dimensions of PN 63 Flanges EN 1092-1 NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. Dimensions in mm * For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter. NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. Flanges PN 100 EN1092-1 Dimensions of PN 100 Flanges EN 1092-1 NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. Dimensions in mm * For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter, NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser. FLANGES according to EN 1092-1 Flange facing dimensions according to EN 1092-1 standard Type A flat face Type B raised face Type C tongue face Type D groove face Type E spigot Type F recces Type G O ring recess Type H O ring groove * For PN 160 flnages form can be only B2, C and D
/
本文档为【EN1092法兰标准】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索