为了正常的体验网站,请在浏览器设置里面开启Javascript功能!

中英文电气安装说明和图例

2019-08-21 31页 doc 63KB 40阅读

用户头像

is_842972

暂无简介

举报
中英文电气安装说明和图例中英文电气安装说明和图例 LUMINAIRE 灯具 1x28W T5 Batten Surface/Wall Mount fluorescent fitting 1x28W T5 条形表面安装/壁装荧光灯 2x28W T5 Batten Surface/Wall Mount fluorescent fitting 2x28W T5 条形表面安装/壁装荧光灯 1x28W T5(IP65) fluorescent fitting 1x28W T5 (IP65) 荧光灯 2x28W T5(IP65) fluores...
中英文电气安装说明和图例
中英文电气安装说明和图例 LUMINAIRE 灯具 1x28W T5 Batten Surface/Wall Mount fluorescent fitting 1x28W T5 条形表面安装/壁装荧光灯 2x28W T5 Batten Surface/Wall Mount fluorescent fitting 2x28W T5 条形表面安装/壁装荧光灯 1x28W T5(IP65) fluorescent fitting 1x28W T5 (IP65) 荧光灯 2x28W T5(IP65) fluorescent fitting 2x28W T5 (IP65) 荧光灯 1x14W Batten Surface/wall mount fluorescent fitting 1x14W 条形表面安装/壁装荧光灯 2x28W recessed/suspended mount luminaire fitting 2x28W 嵌入式/悬挂式灯具 1x240W metal halide fitting 1x240W 金属卤化灯具 1x18W (IP65) surface mounted luminaire 1x18W(IP65) 表面安装的照明灯具 1x26W Rectangular wall recessed luminaire 1x26W 方形墙面嵌入式照明灯具 2x28W Fluorescent fitting C/W prismatic diffuser 2x28W 荧光灯,包括棱镜式散光罩 1x26W PLC recessed down-light 1x26W PLC 嵌入式筒灯 2x26W PLC recessed down-light 2x26W PLC 嵌入式筒灯 2x18W PLC recessed down-light 2x18WPLC 嵌入式筒灯 11W recessed/suspended mount down-light 11W 嵌入式/悬挂式筒灯 1x150W high bay light 1x150W 高顶灯 2x55W weatherproof (IP54) aircraft obstruction light 2x55W 防雨(IP54)航空障碍灯 A-denotes fitting connected to battery pack (type as above) A指示灯,同电池组相连接(类型同上) Single sided exit light (Type E1) 单侧出口灯(类型E1) Similar to Type E1 but with an additional arrow pointing to the right (Type E2) 同类型E1相似,但是多一个向右的指示箭头(类型E2) Similar to Type E1 but with an additional arrow pointing to the left (Type E3) 同类型E1相似,但是多一个向左的指示箭头(类型E3) Double faced exit light with an additional arrow on each face pointing to the left/right as appropriate (Type E4) 双面出口灯,每面多一个指示箭头,指示左或者右(视情况而定)(类型E4) Similar to Type E1 but with an additional arrow pointing to the opposite directions (Type E5) 同类型E1相似,但是多一个指示箭头,指示相反的方向(类型E5) Switches开关 LTG SW., 1 Gang One-way (Lighting)照明开关,1组单向 LTG SW., One-way (2S denotes 2 Gang) 照明开关,单向(2S表示2组) LTG SW., Two-way 照明开关,双向 LTG SW., Two-way (2S denotes 2 Gang) 照明开关,双向(2S表示2组) Intermediate LTG SW., 1Gang 中间照明开关,1组 Intermediate LTG SW (2S denotes 2 Gang) 中间照明开关(2S表示2组) Weatherproof LTG SW 防雨照明开关 Flameproof LTG SW 防火照明开关 DP LTG SW., 1Gang One-way 双杆照明开关(Double Pole),1组单向 Intermediate LTG SW (2S denotes 2Gang) 中间照明开关(2S表示2组) Weatherproof LTG SW 防雨照明开关 Splash-proof LTG SW 防溅式照明开关 DP LTG SW., 1 Gang One-way 双杆照明开关,1组单向 Lighting switch panel 照明开关柜 Denotes switches of metal-clad type 金属壳开关(铠装) Dimmer C/W switch 调光器,包括开关 Dimmer rack 调光柜 Dimmer switch panel (Digital type) 调光器开关柜(数字型) 20A DP switch C/W neon indication lamp and marked “water heater” 20安培双杆开关,包括氖管指示灯,并标示“热水器” 20A DP switch C/W neon indication lamp and marked “washing machine” 20安培双杆开关,包括氖管指示灯,并标示“洗衣机” Bell push switch marked with Bell symbol 铃按钮开关,并标记有“铃”符号 Door chime point 门铃 Buzzer point 蜂铃 Electrical Air/oil/vacuum circuit breaker (Rating and No. of poles as shown) 空气、油压、真空断路器 Moulded case/miniature circuit breaker (Rating and No. of poles as shown) 断路器模块、小型断路器(跳菲) Residual current circuit breaker (RCCB) Rating and No. of poles as shown 漏电断路器、漏电保护器 DB/MB/MP/SSB/ESSB/LSB/LDB 配电盘、量表板、计量盘、分配电板、电梯配电盘 MSB/EMSB/GCP/PCP 主配电柜、发电机控制箱、泵控制箱 Subsidiary control panel 辅助控制柜 Tenant’s metering panel C/W MCBs subsidiary control panel and isolating SW. to powergrid’s approval 租户计量盘,包括微型断路器二级控制箱和隔离开关(获得电网批准) Over-ground distribution box 地上配电箱 Isolation SW (Rating as shown) 隔离开关 Fuse switch (Rating as shown) 熔丝开关、保险丝开关 Switch-fuse (Rating as shown) 开关熔断器、开关保险丝 Fireman’s switch 消防开关 Junction box 接线箱 Cable end C/W termination kit 电缆端头,包括端子箱 Ammeter 安培表 V oltmeter 电压表 Power factor meter 功率因数表 Frequency meter 频率计 Kilowatt meter 电力计、千瓦计 Kilowatt-hour meter 电表 Maximum demand meter with alarm 最大需量计,带警报 Hour run meter 运行小时计 Energy monitoring device comprising current transformers, transducers, etc. For remote reading/logging of kilowatt-hour consumption 能量监测装置,包括电流变压器、变送器等,用于远程读取、记录电能损耗 Overcurrent/earth fault protection relay with instantaneous high set element (IDMTL characteristic unless otherwise indicated) 过电流、接地故障保护继电器。 Overcurrent protection relay with instantaneous high set element (IDMTL characteristic unless otherwise indicated) 过电流保护继电器 Earth fault relay (IDMTL characteristic) 接地故障继电器 Earth fault delay with definite time lag 接地故障继电器(时滞、时迟) Earth leakage relay 接地漏电继电器 Restricted earth fault relay 受限接地故障继电器 Solid-state zone selective earth fault relay 固态区域选择性接地故障继电器 Pilot wire protection relay 控制线路保护继电器 HRC fuse (Rating as shown) 高断开容量保险丝 Pilot indicating light 航向指示灯 Selector SW 选择器开关 Time SW C/W by-pass SW 定时开关,包括旁路开关 Remote trip push button 远程跳闸按钮开关 Change-over contactor (Rating & No. of pole as shown) 切换触头(接触器) Automatic transfer SW (Rating as shown) 自动换向开关 Manual transfer SW (Rating as shown) 手动换向开关 Current transformer 电流变压器 V oltage transformer 电压变压器 HRC fused tap-off unit (Rating as shown)高断开容量熔接分线设备(见额定值) MCCB Tap-off Unit (Rating as shown)模块断路器分线设备(见额定值) Busbar termination box母排端接箱 End feed unit端部馈电装置 Center feed unit中心馈电装置 Standby generator set备用发电机组 Power transformer电源变压器 Fan Ceiling fan 吊风扇 Wall mounted fan 壁挂风扇 Ceiling oscillating fan 吊式摇头风扇 Fan regulator C/W SW 风扇调节器,包括开关 Power: SSO—开关插座 13A SSO, 1 Gang (Switched Socket-outlet) 13A 开关插座,1组 13A SSO, 2 Gang 13A开关插座,2组 13A Weatherproof SSO 13A 防雨开关插座 13A SSO mounted at high level 13A 开关插座,安装于高处 13A Splash-proof SSO (For washing machine) 13A 防溅开关插座(用于洗衣机) 15A splash-proof SSO (For washing machine) 15A 防溅开关插座(用于洗衣机) 13A metalclad SSO mounted within false ceiling space 13A 金属壳开关插座(假吊顶内) 15A metalclad SSO mounted within false ceiling space 15A 金属壳开关插座(假吊顶内) 13A SSO mounted within false ceiling space (For air conditioner) 假吊顶内安装的13A 开关插座(用于空调) 13A SSO mounted within false ceiling space (For hand dryer/hair dryer) 假吊顶内安装的13A开关插座(用于烘手机、吹风机) 13A SSO mounted within false ceiling space (For flush valve) 安装于假吊顶内的13A开关插座(用于冲洗阀) Denotes SSOs of metalclad type 表示金属壳式开关插座 13A fused connection unit 13A熔接装置 20A fused connection unit 20A熔接装置 13A connection unit连接装置 20A connection unit 连接装置 C-denotes mounted within false ceiling space C表示安装于假吊顶内 HL-Denotes mounted at high level HL表示安装于高处 Cooker control unit 炊具控制装置 Sound System Surface mounted (wall/ceiling) loudspeaker 安装于表面(墙面、天花顶)的扬声器 Loudspeaker (recessed in false ceiling) 嵌入假吊顶内的扬声器 Column loudspeaker 音柱 Ceiling loudspeaker (For emergency announcement only) 吸顶式扬声器(ceiling mounted loudspeaker),仅用于紧急通知Horn loudspeaker 喇叭形扬声器 Amplifier (Rating as shown) 扩音器 Microphone input 麦克风(传声器)输入口 Speaker volume control 扬声器音量调节器 PA interface for local reinforcement sound system 用于局部增强音响系统的公共广播接口 Override control for the local sound system 用于局部音响系统的过调节控制 Telephone Installation电话安装Telephone outlet 电话出线口 Telephone outlet (Floor mounted type) 电话出线口(地面安装式) Telephone outlet (Mounted on floor pedestal) 电话出线口(安装于地面柱墩上) Telephone outlet (Mounted flush with floor finishes) 电话出线口(安装高度同完成地面齐平) Distribution panel 配电箱 Telephone termination box (Terminal Box) 电话端接箱(端子箱) Intermediate distribution frame 中间配线架 Private automatic branch exchange 专用自动交换分机 Computer Installation计算机安装 Knock-out box C/W blank plate mounted flushed with FLR finishes (For computer) 分离箱,包括盲板,同完成地面齐平 Computer outlet 计算机电源插座 Security System安保系统 Videophone 可视电话 Visitor call panel访问者呼叫面板 Door alarm contact门报警触头 Magnetic shutter door contact磁性百叶门触点 Window alarm contact窗户报警触头 Card access reader门禁读卡器 Movement detector 移动探测器 Infra-Red Detector红外线探测器 Vibration detector震动检测器 Master unit for fireman intercom system消防员内部通信系统主部件 Fireman intercom outlet消防员内部通信插座 Building intercom outlet建筑内部通信插座 Master building intercom主建筑内部通信 Panic button应急开关、紧急按钮 Panic bolt lock应急螺栓锁 Watchman/guard tour station看护、门卫值班站 Local alarm bell局部报警铃 Local alarm panel 局部警报控制盘 Electric lock interface point (Electric lock by others) 电动锁接口(其他方安装电动锁) Fixed type CCTV Camera (Wall mounted/suspended) 固定式CCTV摄像头(安装于墙面或者悬挂式) Fixed type CCTV camera (Housed in a weather-proof housing) 固定式CCTV摄像头,带防雨外罩 Camera with pan/tilt/auto iris and pre-positioning facilities 自动光圈式摄像头和预定位设施 Camera with pan/tilt/zoom/auto iris and pre-positioning facilities 可变焦距摄像头/自动光圈式摄像头和预定位设施 CCTV camera with standard lens concealed in wall or ceiling CCTV 摄像头,镜片隐藏在墙内或者天花板内 CCTV camera with pin hole lens concealed in wall or ceiling CCTV 摄像头,针孔镜头隐藏在墙内或者天花板内 MATV Installation主天线电视安装 TV/FM Co-Axial outlet TV/FM同轴插座 2-way splitter 2向分流器 4-way splitter 4向分流器 1-port tap-off unit单孔分线设备 2-port tap-off unit双孔分线设备 4-port tap-off unit 四孔分线设备 Multi-tap unit (n denotes NOs of ways)转接插座装置 1-port terminal unit (end unit)单孔终端设备 2-port terminal unit (end unit) 双孔终端设备 4-port terminal unit (end unit) 四孔终端设备 Distribution amplifier 配电放大器 75 OHM resistor 75欧姆电阻器 Cable tray/ladder Cable tray for Tel. cable 电话电缆桥架 Cable tray for Elect.Cable 电气电缆桥架 Cable tray for Computer cable 计算机电缆桥架 Cable ladder for Tel. cable 电话电缆梯架 Cable ladder for Elect.Cable 电气电缆梯架 Earthing System Earthing point (For Elect.Installation) 电气安装接地点 Earthing point (For lightning protection system) 防雷系统接地点 Earthing point (For generator installation) 发电机安装接地点 Earthing point (For computer installation) 计算机安装接地点 Earthing point (For telephone installation) 电话安装接地点 Earthing point (For underground fuel storage tank) 地下燃料储存箱接地点 Lightning Protection System Air terminal 避雷针 Lightning stub Tape joint 带条粘接缝 Down conductor引下线 25mm x 3mm tape (Copper unless otherwise indicated) 25mm x 3mm 铜带25mm x 3mm aluminum tape 25mm x 3mm 铝带 General All SSOs,isolating switches, etc. marked“WP” shall be of the weather-proof type 标示为WP的全部转化电器插座、隔离开关,应该是防雨型的。 Mounting height from FFL to centerline in millimeters (mm) 自完成面到中心线的安装高度(mm) Mounting height from work-stop to centerline in millimeters (mm) Water heater (By others) 热水器 Twin switch 双联开关 ABBREVIATION缩略词 ACVI Air conditioning & ventilation installation 空调和通风安装 ADJ Adjacent 相邻、临近 ADMD After diversity maximum demand最大需量 CA TV Communal antenna television system公共天线电视系统 CCC Computer-based control Center计算机控制中心 CCT Circuit电路 CCTV Closed Circuit Television闭路电视 CL:Connected Load 连接负荷 CP:control Panel 控制箱 C/U:Connection Unit 连接盒 C/W: Complete with 包括 DB:Distribution Board 配电盘 DP:Double Pole 双杆 EBOP:Emergency Battery-Operated Supply Unit 应急蓄电池驱动供电装置ELCB:Earth Leakage Circuit Breaker 接地漏电断路器 EMSB:Essential Main Switchboard 主配电盘 ESSB:Essential Sub-switchboard 二级配电盘 FCC:Fire Command Centre 消防指挥中心 FCU:Fan Coil Unit 风机盘管 FFAI:Fire Fighting & Alarm Installation 消防报警安装 FFL:Finished Floor Level完成地坪标高 FLR:Floor 地面 4P:Four Pole GCP:Generator Control Pane发电机控制箱 HRC:High Rupturing Capacity 高断开容量 JB:Junction Box 接线箱 LTG:Lighting照明 LDB:Lift Distribution Board电梯配电柜 LSB:Lift switchboard 电梯配电盘 MATV:Master Antenna Television System 主天线电视系统 MB:Metering Board仪表板 MCB:Miniature circuit breaker 小型断路器 MCCB:Moulded case circuit breaker 模块断路器 MD:Maximum Demand最大需量 MP:Metering Panel计量盘 MSB:Main Switchboard 主配电盘 PCP:Pump control panel泵送控制箱 PSCC:Prospective short circuit current 预期短路电源 PSI:Plumbing & sanitary installation 卫生管道和卫生设施安装 RCCB:Residual current circuit breaker 残余电流断路器 S/C:Signal & control信号和控制器 SEC:Secondary 二级 SGS:Standby generator set备用发电机 SP:Single pole 单级 SPN:Single pole & neutral 单级和中性 SSB: Sub-switchboard分配电板 SSO: Switched socket-outlet开关插座 SW:Switch 开关 Tel:Telephone 电话 TKG:Trunking线槽 TP:Triple Pole 三极 TPN:Triple pole & neutral TR:Transformer 变压器 TV: Television 电视 T/U: Terminal Unit 终端装置 V AB:Vertical access box竖向接入盒 V A V:Variable air volume 变风量空调系统 VENT: 通风 WP:Weatherproof 防雨的 ZCT:Zero sequence current transformer零序电流变压器 Note 1.The entire electrical installation shall be in compliance with the current edition of Singapore Standard CP5: Code of Practice for Electrical Installations. 整体电气安装,应该按照现行版的新加坡标准CP5(电气安装操作规范)执行。 2.Weatherproof materials/fixtures/equipment, etc., shall be used for installation works in areas where exposed to weather. 防雨、灯具和设备等,安装于受天气影响的区域。 3.Unless shown otherwise the mounting height from finished floor level for the various items of electrical equipment shall be as follows: 除非有明确显示,电气设备的安装高度(距离完成地面高度)按照如下要求执行: 3.1Lighting switches,Remote trip buttons, Isolating switches, etc——-1400mm to center line 照明开关、远程跳闸按钮、隔离开关等——距离中心线1400mm 3.213A & 15A Switch socket outlets, telephone outlets, fused connection units ——-1400mm to center line for Carpark areas, Kitchens, stores, plantrooms areas. 300mm to center line for all other areas or 150mm above work top, if applicable. 13A&15A开关插座、电话插座、熔接装置——停车场、厨房、仓房、设备室内,距离 中心线1400mm;剩余区域,距离中心线300mm,或者工作台面以上150mm。 3.313A & 15A switch socket outlets, fused connection units at high level——High level to suit equipment served. Final position to be approved by architect. 高空位置的13A & 15A开关插座、溶解装置——最终位置有建筑师批准。 3.4Wall mounted lights——2500mm to center line 壁灯——距离中心线2500mm 3.5Suspended lighting fitting——3000mm to underside of fitting except those to be mounted flush with false ceiling panel. 吊顶灯——距离灯具下侧3000mm,同假天花板齐平的吊顶灯除外。 3.6Distribution boards——Generally 1500mm to center line 配电盘——距离中心线1500mm。 3.7Metering panels——Minimum 1000mm, maximum 1800mm to center of KWH meter 计量盘——距离电表中心最下1000mm,最大1800mm。 3.8Wall mounted CCTV cameras——150mm below ceiling/slab 墙面安装的CCTV摄像头——天花板/地板以下150mm 4.Notwithstanding the general location and mounting heights shown for the various items of equipment, they are subject to final adjustment at site to suit the site conditions and/or the requirements of the architect. 虽然如上规定了各种电气设备的安装位置和安装高度,但是,这些电气设备需要很据现场条件和建筑师的要求,现场做出调整。 5.Unless otherwise shown on the drawing or agreed with the architect, all cable trays & ladders shall be suspended at 450mm from ceiling slabs or 300mm from underside of beams or other trays/services. Layout of cable trays/ladders including cable layout on each tray/ladder, busbartrunkings, connections/routes,etc., shall be submitted to the architect for review prior to installation. 除非图纸上另有显示或者同达成一致,所有电缆桥架和梯架悬挂高度为,距离天花板450mm,或者距离梁、其他桥架/设施底部300mm。安装前,电缆桥架和梯架平面布置,包括每个电缆桥架/梯架、母排线槽内电缆布置、连接和路径等,需要提交设计审批。 6.除了电话电缆桥架外,图纸上显示的电缆桥架、梯架、框架系统和电缆槽的尺寸,仅仅 是指示性的。分包商负责选择合适尺寸的电缆桥架、梯架、框架系统,安装电缆、母排线槽等。选取的电缆桥架和梯架尺寸,要保证电缆、母线线槽之间具有足够的间隙,使电缆和母排的设计额定值不受影响。空间有限的区域,使用多层桥架、框架系统。 7.除非另有说明,所有单线图中显示的PVC和防火等级电缆,要按照规范要求的方法, 装入穿线管内或者线槽内。95mm及以上的电缆,要安装于电缆桥架或梯架上。 8.除非另有说明,单线图和其他图纸上显示的所有PVC、PVC和XLPC、PVC电缆,应 该安装固定于电缆桥架或梯架上。 9.使用专门制作的挠性连接线,将母排同交流发电机端子连接。连接线的额定值同母排等 同。 10.电缆安装完毕后,按照设计要求,过挡土墙的所有套管和引入管(包括备用的)需要由 分包商合理密封、接地,防止地下水流入。 11.所有供油管和回油管,包括沿停车场、公用走廊安装的支撑架(备用发电机房、燃油泵 房和管道竖井内安装的支撑架除外),应该完全封闭在石膏玻璃或者其他具有2小时防火等级的材料内(材料需要获得FSB批准认可)。 12.投标商需要检查确认,并且在提交的标内强调说明,若规范图纸上提供的变电站、开 关室、竖向电气管等,根据分包合同,不能容纳投标商提供的设备。 13.关于景观照明,园景树栽种之前,分包商需要去掉接入园景树的电气管。园景树安装完 毕后,再安装灯具,灯具的具体位置,根据园景树位置,现场再做调整。 14.每盏外置风景灯应该配有降压变压器、控制器、功率因数矫正电容器、电源接触器、辅 助零件、端子箱,以及安全顺利操作照明装置需要的安装支架等。 15.电气系统、防雷系统等显示的接地极和接地井的数量和位置,只是指示性的。分包商负 责按照相关规范要求,对现场要求达到接地值的位置,提供充足的接地极和接地井。 16.显示各种系统的原理框图,描述不出各种设备实际的连接方式。 17.每个辅助干线和末极电路,应该带有电路保护导体,导体横截面积计算如下: S(横截面积mm2)= I=故障电流(A.C RMS) T=保护装置的工作时间 K=保护导体的材料因数 或者按照CP5:1998 Table 54G选取: 相导体(mm2)接地连续性导体(mm2) S≤16 S 16∠S≤35 16 S大于35 S/2 18.开关柜母排的电流密度不超过1.55Amp每平方毫米。 19.如上说明适用于所有相关图纸。
/
本文档为【中英文电气安装说明和图例】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
热门搜索

历史搜索

    清空历史搜索