为了正常的体验网站,请在浏览器设置里面开启Javascript功能!

delll错误代码(Delll error code)

2018-04-29 20页 doc 54KB 112阅读

用户头像

is_633423

暂无简介

举报
delll错误代码(Delll error code)delll错误代码(Delll error code) delll错误代码(Delll error code) DELL server error code E1000 Failsafe, voltage, error., Contact, support. (fault protection, voltage error. Please contact support staff View system event records for serious fault events. Disconnect the ...
delll错误代码(Delll error code)
delll错误代码(Delll error code) delll错误代码(Delll error code) DELL server error code E1000 Failsafe, voltage, error., Contact, support. (fault protection, voltage error. Please contact support staff View system event records for serious fault events. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E1114 Ambient, Temp, exceeds, allowed, range. (ambient temperature is beyond the permitted range) The ambient temperature reaches a point beyond the allowable range. Please see "system cooling issues, troubleshooting."". E1116 Memory, disabled, temp, above, range., Power, cycle, AC. (disable memory, temperature out of range). Please turn off the AC power and turn on The memory has exceeded the license temperature, and the system has disabled it to prevent component damage. Disconnect the AC power of the system for 10 seconds, then restart the system. Please see "system cooling issues, troubleshooting."". If the problem persists, see "get help"". E1210 Motherboard battery failure. Check battery. (motherboard battery failure. Check the battery, please CMOS battery missing or voltage out of license range. Please refer to system battery troubleshooting". E1211 RAID, Controller, battery, failure., Check, battery. (RAID controller, battery fault). Check the battery, please The RAID battery is lost or damaged or cannot be recharged due to temperature problems. Insert the RAID battery connector again. See "installing RAID batteries" and "system cooling problems, troubleshooting."". E1216 3.3V, Regulator, failure., Reseat, PCIe, cards., 3.3V (voltage regulator failure). Please reset the PCIe card 3.3V regulator failure. Please remove and reset the PCIe expansion card. If the problem persists, see the "expansion card troubleshooting"". E1229 CPU VCORE Regulator failure. Reseat CPU. # (CPU # VCORE regulator fault. Reset CPU, please.) The VCORE regulator of a particular processor is out of order. Please reset the processor. See processor troubleshooting". If the problem persists, see "get help"". E122A CPU VTT Regulator failure. Reseat CPU. # (CPU # VTT regulator fault. Reset CPU, please.) The VTT regulator of a particular processor is out of order. Please reset the processor. See processor troubleshooting". If the problem persists, see "get help"". E122C CPU, Power, Fault., Power, cycle, AC. (CPU power failure. Please turn off the AC power and turn on A power failure is detected when the processor power is turned on. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E122D Memory Regulator Failed. Reseat (DIMMs. # memory regulator # fault. Reset DIMM, please.) A memory voltage regulator failed. Reset memory module. Please see "system memory troubleshooting."". E122E 机上调节器失败。电话支持。(机载稳压器故障。请联络支持人员。) 某个内置稳压器出现故障。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e1310 # #风扇转速超出范围。检查风扇。(风扇# #转速超出范围。请检查风扇。) 特定风扇的每分钟转数超出预期的操作范围。 请参阅”系统冷却问题故障排除”。 e1311 风扇模块# #转速超出范围。检查风扇。(风扇模块# #转速超出范围。请检查风扇。) 特定模块中的特定风扇的每分钟转数超出预期的操作范围。 请参阅”系统冷却问题故障排除”。 e1313 风扇冗余丢失。检查风扇。(风扇冗余丢失。请检查风扇。) 系统中的风扇不再有冗余如果再次发生风扇故障,系统将存在过热危险。 请查看液晶以了解其它滚动信息请参阅”风扇故障排除”。 e1410 系统出现致命错误。(检测到系统严重错误。) 检测到严重的系统错误。 请查看液晶以了解其它滚动信息。断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e1414 CPU #温度超出范围。检查CPU散热器。(CPU #温度超出范围。请检查CPU散热器。) 特定处理器已超出可接受的温度范围。 请确保已正确安装了处理器的散热器。请参阅”处理器故障排除”和”系统冷却问题故障排除”。 e1418 CPU #未检出。检查CPU正确就位。(未检测到CPU #。请检查CPU是否正确就位。) 指定的处理器丢失或损坏,系统的配置不受支持。 请确保指定处理器已正确安装请参阅”处理器故障排除”。 e141c 不支持的CPU配置。检查CPU或BIOS版本。(CPU配置不受支持。请检查CPU或BIOS版本。) 不支持处理器的配置 请确保您的处理器与系统的《使用入门指南》中概述的处理器技术规格所述的型号相符并匹配。 e141f CPU #错误。动力循环的AC.(CPU #协议错误。请关闭交流电源再打开。) 系统BIOS已报告处理器协议错误。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 系统BIOS已报告 总线奇偶校验错误。动力循环的AC.(CPU总线奇偶校验错误。请关闭交流电源再打开。) 系统BIOS已报告处理器总线奇偶校验错误。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在, See "get help."". E1422 CPU machine check error. Power cycle AC. # (CPU # machine check error. Please turn off the AC power and turn on System BIOS has reported machine check errors. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E1610 Power Supply (W # ###) missing. Check power supply. (power equipment # (### W) lost. Please check the power supply equipment Specific power equipment is removed or the system is missing this device. Please refer to troubleshooting the power supplies". E1614 Power Supply (W # ###) error. Check power supply. (power equipment # (### W) error. Please check the power supply equipment A specific power failure. Please refer to troubleshooting the power supplies". E1618 Predictive failure on Power Supply (W # ###). Check PSU. (power equipment # (### W) forecasting fault. Check PSU, please.) A power fan failure, excessive temperature, or power communication errors result in an early warning of a power failure. Please refer to troubleshooting the power supplies". E161C Power Supply (W # ###) lost AC power. Check PSU cables. (power equipment # (### W) AC power interruption. Check the PSU cable, please A specific power device has been connected to the system, but no AC input is available. Check the AC power supply of the specified power supply. If the problem persists, refer to troubleshooting the power supplies". E1620 Power Supply (W # ###) AC power error. Check PSU cables. (power equipment # (### W) AC power error. Check the PSU cable, please The AC input of a specific power device is beyond the license range. Check the AC power supply of the specified power supply. If the problem persists, refer to troubleshooting the power supplies". E1624 Lost, power, supply, redundancy.Check, PSU, cables. (loss of power, device redundancy). Check the PSU cable, please The power device subsystem no longer offers redundancy. If the rest of the power device is wrong, the system will turn off. Please refer to troubleshooting the power supplies". E1626 Power Supply Mismatch. PSU1 = W PSU2 = W. ###, ### (power equipment matching. PSU1 = W PSU2 = W ###, ###). The power supply in the system is different in power. Make sure that the power matching device is installed. Please refer to the technical specifications listed in the system's use guide. E1629 Power, required > PSU, wattage., PSU, and, config., Check (the required power is greater than PSU power. Please check PSU and configuration System configuration requires greater power than the power supply provided by the power device, even when throttling is present. Turn off the system power, reduce the hardware configuration, or install a higher power device, and then restart the system. E1710 输入输出通道检查错误。请检查并清除SEL.(I/O通道检查错误。请 检查并清除SEL。) 系统BIOS已报告I/O通道检查。 请查看SEL中的详细信息,然后清除SEL。断开系统的交流电源10 秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e1711 在公共汽车# #装置# #功能# # PCI奇偶校验错误(总线# #设备# # 功能# # PCI奇偶校验错误) 系统PCI BIOS已报告组件发生奇偶校验错误,该组件位于总线# # 设备# #功能# #的PCI配置空间。 请卸下并重置PCIe扩充卡如果问题仍然存在,请参阅”扩充卡故障 排除”。 #插槽上的PCI奇偶校验错误。请检查并清除SEL.(插槽#上PCI奇偶校验错误。请检查并清除SEL。) 系统PCI BIOS已报告位于指定插槽中的组件发生奇偶校验错误。 请卸下并重置PCIe扩充卡如果问题仍然存在,请参阅”扩充卡故障排除”。 e1712 在公共汽车# #装置# #功能# # PCI系统误差(总线# #设备# #功能# # PCI系统错误) 系统PCI BIOS已报告组件发生系统错误,该组件位于总线# #设备# #功能# #的PCI配置空间。 请卸下并重置PCIe扩充卡如果问题仍然存在,请参阅”扩充卡故障排除”。 # PCI插槽上的系统误差。请检查并清除SEL.(插槽# PCI系统错误。请检查并清除SEL。) 系统PCI BIOS已报告组件发生系统错误,该组件位于指定的插槽。 请重新安装扩充卡提升板。请参阅”扩充卡和扩充卡提升板”。如果问题仍然存在,则示提升卡或系统板出现故障请参阅”获得帮助”。 e1714 未知错误。请检查并清除SEL.(未知错误。请检查并清除SEL。) 系统BIOS已确定系统中存在错误,但无法确定错误来源。 请查看SEL中的详细信息,然后清除SEL。断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e1715 致命的I/O错误(严重I/O错误)审查和明确的选择。(请检查并清除SEL。) 系统BIOS判定系统中存在严重错误。 请查看SEL以了解详细信息,然后清除SEL。断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 芯片 芯片组ierr总线# #开发# #功能# #。请检查并清除SEL.(芯片集ierr总线# #设备# #功能# #。请检查并清除SEL。) 系统BIOS报告了驻留在总线# #,设备# #,功能# #中的芯片集内部错误。 See SEL for more information, and then clear SEL. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E1717 CPU internal error. Review # & clear SEL. (CPU # internal error. Check and clear SEL, please.) The system BIOS determines that an internal error has occurred in the specified processor. See SEL for more information, and then clear SEL. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E171F PCIe fatal error on Bus Device Function ## ## ## (## ## ## PCIe bus device function fatal error) BIOS has reported fatal error PCIe components, the components of the PCI configuration space is located in the ## ## function of ## bus equipment. Please remove and reset the PCIe expansion card. If the problem persists, see the "expansion card troubleshooting"". PCIe fatal error on Slot Review & clear SEL. (#. slot # PCIe fatal error. Check and clear SEL, please.) The system BIOS has reported a fatal PCIe error in the component located in the specified slot. Please reinstall the expansion card lifting plate. Please refer to the "expansion card" and the "expansion card lift board"". If the problem persists, the upgrade card or system board fails. See "get help."". E1810 Hard drive fault. Review & clear SEL. ## (hard disk drive ## fault. Check and clear SEL, please.) The specified hard disk drive is out of order. Please refer to "hard disk drive troubleshooting."". E1812 Hard drive removed. Check drive. ## (hard disk drive ## removed. Please check the drive The specified hard drive has been removed from the system. For reference only. E1A11 The PCI Riser Hardware & configuration mismatch. Reconfigure. (PCI board hardware does not match the configuration. Please reconfigure PCIe lift plate configuration is incorrect. Some invalid configuration prevents the system from energizing. Please reinstall the expansion card lifting plate. Please refer to the "expansion card" and the "expansion card lift board"". If the problem persists, the upgrade card or system board fails. See "get help."". E1A12 PCI, Riser, not, detected., Check, Riser. (PCI lift plate not detected). Check the lift panel, please Lose one or two PCIe lifting plates. This will prevent the system from starting. Please reinstall the missing lifting card. Please refer to "installing expansion card, lifting board 1" and "installing expansion card", lifting board 2". E1A14 SAS, cable, A, failure., Check, connection. (SAS cable, A fault). Please check the connection SAS cable A missing or damaged. Reset cable. If the problem persists, replace the cable. If the problem persists, see "get help"". E1A15 SAS, cable, B, failure., Check, connection. (SAS cable, B fault). Please check the connection SAS cable B missing or damaged. Reset cable. If the problem persists, replace the cable. If the problem persists, see "get help"". E1A1D Control, panel, USB, cable, not, detected., Check, cable. (USB panel of control panel not detected). Please check the cable The USB cable connected to the control panel is missing or damaged. Reset cable. If the problem persists, replace the cable. If the problem persists, see "get help"". E2010 Memory not detected. Inspect DIMMs. (memory not detected). Check DIMM, please.) Memory was not detected in the system. Install memory or reset memory module. See "installing memory modules" or "system memory troubleshooting."". E2011 Memory, configuration, failure., Check, DIMMs. (memory configuration failure. Check DIMM, please.) Memory detected, but memory cannot be configured. Error detected during configuration memory. Please see "system memory troubleshooting."". E2012 Memory, configured, but, unusable., Check, DIMMs. (memory is configured, but not available. Check DIMM, please.) Memory is configured, but not available. Please see "system memory troubleshooting."". E2013 BIOS, unable, to, shadow, memory., Check, DIMMs. (BIOS) cannot access shadow memory. Check DIMM, please.) The BIOS system can not be copied to the memory in the flash image. Please see "system memory troubleshooting."". E2014 CMOS, RAM, failure., Power, cycle, AC. (CMOS, RAM) fault. Please turn off the AC power and turn on CMOS is out of order. CMOS RAM doesn't work properly. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E2015 DMA, Controller, failure., Power, cycle, AC. (DMA controller failure). Please turn off the AC power and turn on The DMA controller is out of order. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E2016 Interrupt, Controller, failure., Power, cycle, AC. (interrupt controller failure). Please turn off the AC power and turn on The interrupt controller is out of order. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E2017 Timer refresh failure. Power cycle AC. (timer refresh fault). Please turn off the AC power and turn on Timer refresh fault. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". E2018 Programmable, Timer, error., Power, cycle, AC. (programmable timer error). Please turn off the AC power and turn on Programmable interval timer error. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "get help"". 奇偶 奇偶校验错误。动力循环的AC.(奇偶校验错误。请关闭交流电源再打开。) 奇偶校验错误。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e201a 系统故障。动力循环的AC.(上故障。请关闭交流电源再打开。) SiO出现故障。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e201b 键盘控制器错误。动力循环的AC.(键盘控制器错误。请关闭交流电源再打开。) 键盘控制器故障。(键盘控制器故障。) 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e201c 初始化失败。动力循环的AC.(SMI初始化失败。请关闭交流电源再打开。) 系统管理中断(SMI)初始化失败。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e201d 关机测试失败。动力循环的AC.(关闭检测程序失败。请关闭交流电源再打开。) BIOS关闭检测程序失败。 断开系统的交流电源10秒,然后重新启动系统。 如果问题仍然存在,请参阅”获得帮助”。 e201e 内存后测试失败。Check DIMMs。(后内存检测失败。请检查DIMM。) BIOS内存检测失败。 请参阅”系统内存故障排除”。 如果问题仍然存在,请参阅”获得帮助”。 E2020 cpu配置失败。请检查屏幕信息。(CPU配置失败。请检查屏幕信息。) 处理器配置失败。 请查看屏幕上的具体错误信息请参阅”处理器故障排除”。 E2021 不正确的内存配置。请参阅用户指南。(内存配置不正确。请参阅用户指南。) 内存配置不正确。 请查看屏幕上的具体错误信息请参阅”系统内存故障排除”。 e2022 岗位普遍失败。请检查屏幕信息。(后期间一般故障。请检查屏幕信息。) 视频后出现一般故障。 请查看屏幕上的具体错误信息。 e2023 BIOS无法镜像内存。Check DIMMs。(BIOS无法镜像内存。请检查DIMM。) 由于内存模块发生故障或内存配置无效,系统BIOS无法启用内存镜 像功能。 请参阅”系统内存故障排除”。 e2110 在DIMM # #多位错误。安装DIMM。(DIMM # #上多位错误。请重置 DIMM。) The memory module slot "##" has occurred many errors (MBE). Please see "system memory troubleshooting."". E2111 SBE log disabled on DIMM Reseat DIMM. (DIMM ##. disabled ## on SBE log. Reset DIMM, please.) System BIOS has disabled memory unit error (SBE) records, and no more SBE will be recorded before rebooting the system. "Memory module ##" on behalf of BIOS instructions. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "system memory troubleshooting."". E2113 Mem mirror OFF on DIMM & Power cycle AC. ## ##. (DIMM ## and ## memory mirroring on off. Please turn off the AC power and turn on Since the system BIOS determines too many errors in half of the mirror image, memory mirroring has been disabled. The memory module of the ## and ## "on behalf of BIOS instructions. Disconnect the AC power of the system for 10 seconds, then restart the system. If the problem persists, see "system memory troubleshooting."". I1910 Intrusion, detected., Check, chassis, cover. (intrusion detected). Please check the chassis cover). The system cover has been removed. For reference only. I1911 LCD, Log, Full., Check, SEL, to, review, all, Errors. (LCD log is full. Please check SEL to see all errors LCD overflow information. LCD can display up to ten error messages at most. The eleventh message instructs the user to check the SEL for details of the event. View SEL for event details. Disconnect the AC power of the system for 10 seconds, or clear the SEL. I1912 SEL full. Review & clear log. (SEL is full). Please check and clear the logs The event logged on the SEL is full and cannot record anything else. See the details in SEL, and then clear the SEL. W1228 RAID Controller battery capacity < 24hr. (the battery capacity of the RAID controller is less than 24 hours) Forewarned that the RAID battery has only less than 24 hours of electricity left. Charge the RAID battery to allow the battery to remain in excess of 24 hours. If the problem persists, replace the RAID battery. See "installing RAID batteries."". W1627 Power, required > PSU, wattage., PSU, and, config., Check (the required power is greater than PSU power. Please check PSU and configuration System configuration requires power greater than the power available from the power supplies. Turn off the system power, reduce the hardware configuration, or install a higher power device, and then restart the system. W1628 Performance, degraded., Check, PSU, and, system, configur-ation. (performance degradation). Please check PSU and system configuration System configuration requires greater power than the power supply, but can be guided if throttling is used. Turn off the system power, reduce the hardware configuration, or install a higher power device, and then restart the system. DELL servers, workstations, storage, full range
/
本文档为【delll错误代码(Delll error code)】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索