delll错误代码(Delll error code)
delll错误代码(Delll error code)
DELL server error code
E1000
Failsafe, voltage, error., Contact, support. (fault protection, voltage error. Please contact support staff
View system event records for serious fault events.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E1114
Ambient, Temp, exceeds, allowed, range. (ambient temperature is beyond the permitted range)
The ambient temperature reaches a point beyond the allowable range.
Please see "system cooling issues, troubleshooting."".
E1116
Memory, disabled, temp, above, range., Power, cycle, AC. (disable memory, temperature out of range). Please turn off the AC power and turn on
The memory has exceeded the license temperature, and the system has disabled it to prevent component damage.
Disconnect the AC power of the system for 10 seconds, then restart the system.
Please see "system cooling issues, troubleshooting."". If the problem persists, see "get help"".
E1210
Motherboard battery failure. Check battery. (motherboard battery failure. Check the battery, please
CMOS battery missing or voltage out of license range.
Please refer to system battery troubleshooting".
E1211
RAID, Controller, battery, failure., Check, battery. (RAID controller, battery fault). Check the battery, please
The RAID battery is lost or damaged or cannot be recharged due to temperature problems.
Insert the RAID battery connector again. See "installing RAID batteries" and "system cooling problems, troubleshooting."".
E1216
3.3V, Regulator, failure., Reseat, PCIe, cards., 3.3V (voltage regulator failure). Please reset the PCIe card
3.3V regulator failure.
Please remove and reset the PCIe expansion card. If the problem persists, see the "expansion card troubleshooting"".
E1229
CPU VCORE Regulator failure. Reseat CPU. # (CPU # VCORE regulator fault. Reset CPU, please.)
The VCORE regulator of a particular processor is out of order.
Please reset the processor. See processor troubleshooting".
If the problem persists, see "get help"".
E122A
CPU VTT Regulator failure. Reseat CPU. # (CPU # VTT regulator fault. Reset CPU, please.)
The VTT regulator of a particular processor is out of order.
Please reset the processor. See processor troubleshooting".
If the problem persists, see "get help"".
E122C
CPU, Power, Fault., Power, cycle, AC. (CPU power failure. Please turn off the AC power and turn on
A power failure is detected when the processor power is turned on.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E122D
Memory Regulator Failed. Reseat (DIMMs. # memory regulator # fault. Reset DIMM, please.)
A memory voltage regulator failed.
Reset memory module. Please see "system memory troubleshooting."".
E122E
机上调节器失败。电话支持。(机载稳压器故障。请联络支持人员。)
某个内置稳压器出现故障。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e1310
# #风扇转速超出范围。检查风扇。(风扇# #转速超出范围。请检查风扇。)
特定风扇的每分钟转数超出预期的操作范围。
请参阅”系统冷却问题故障排除”。
e1311
风扇模块# #转速超出范围。检查风扇。(风扇模块# #转速超出范围。请检查风扇。)
特定模块中的特定风扇的每分钟转数超出预期的操作范围。
请参阅”系统冷却问题故障排除”。
e1313
风扇冗余丢失。检查风扇。(风扇冗余丢失。请检查风扇。)
系统中的风扇不再有冗余如果再次发生风扇故障,系统将存在过热危险。
请查看液晶以了解其它滚动信息请参阅”风扇故障排除”。
e1410
系统出现致命错误。(检测到系统严重错误。)
检测到严重的系统错误。
请查看液晶以了解其它滚动信息。断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e1414
CPU #温度超出范围。检查CPU散热器。(CPU #温度超出范围。请检查CPU散热器。)
特定处理器已超出可接受的温度范围。
请确保已正确安装了处理器的散热器。请参阅”处理器故障排除”和”系统冷却问题故障排除”。
e1418
CPU #未检出。检查CPU正确就位。(未检测到CPU #。请检查CPU是否正确就位。)
指定的处理器丢失或损坏,系统的配置不受支持。
请确保指定处理器已正确安装请参阅”处理器故障排除”。
e141c
不支持的CPU配置。检查CPU或BIOS版本。(CPU配置不受支持。请检查CPU或BIOS版本。)
不支持处理器的配置
请确保您的处理器与系统的《使用入门指南》中概述的处理器技术规格所述的型号相符并匹配。
e141f
CPU #
错误。动力循环的AC.(CPU #协议错误。请关闭交流电源再打开。)
系统BIOS已报告处理器协议错误。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
系统BIOS已报告
总线奇偶校验错误。动力循环的AC.(CPU总线奇偶校验错误。请关闭交流电源再打开。)
系统BIOS已报告处理器总线奇偶校验错误。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,
See "get help."".
E1422
CPU machine check error. Power cycle AC. # (CPU # machine check error. Please turn off the AC power and turn on
System BIOS has reported machine check errors.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E1610
Power Supply (W # ###) missing. Check power supply. (power equipment # (### W) lost. Please check the power supply equipment
Specific power equipment is removed or the system is missing this device.
Please refer to troubleshooting the power supplies".
E1614
Power Supply (W # ###) error. Check power supply. (power equipment # (### W) error. Please check the power supply equipment
A specific power failure.
Please refer to troubleshooting the power supplies".
E1618
Predictive failure on Power Supply (W # ###). Check PSU. (power equipment # (### W) forecasting fault. Check PSU, please.)
A power fan failure, excessive temperature, or power communication errors result in an early warning of a power failure.
Please refer to troubleshooting the power supplies".
E161C
Power Supply (W # ###) lost AC power. Check PSU cables. (power equipment # (### W) AC power interruption. Check the PSU cable, please
A specific power device has been connected to the system, but no AC input is available.
Check the AC power supply of the specified power supply. If the problem persists, refer to troubleshooting the power supplies".
E1620
Power Supply (W # ###) AC power error. Check PSU cables. (power equipment # (### W) AC power error. Check the PSU cable, please
The AC input of a specific power device is beyond the license
range.
Check the AC power supply of the specified power supply. If the problem persists, refer to troubleshooting the power supplies".
E1624
Lost, power, supply, redundancy.Check, PSU, cables. (loss of power, device redundancy). Check the PSU cable, please
The power device subsystem no longer offers redundancy. If the rest of the power device is wrong, the system will turn off.
Please refer to troubleshooting the power supplies".
E1626
Power Supply Mismatch. PSU1 = W PSU2 = W. ###, ### (power equipment matching. PSU1 = W PSU2 = W ###, ###).
The power supply in the system is different in power.
Make sure that the power matching device is installed. Please refer to the technical specifications listed in the system's use guide.
E1629
Power, required > PSU, wattage., PSU, and, config., Check (the required power is greater than PSU power. Please check PSU and
configuration
System configuration requires greater power than the power supply provided by the power device, even when throttling is present.
Turn off the system power, reduce the hardware configuration, or install a higher power device, and then restart the system.
E1710
输入输出通道检查错误。请检查并清除SEL.(I/O通道检查错误。请
检查并清除SEL。)
系统BIOS已报告I/O通道检查。
请查看SEL中的详细信息,然后清除SEL。断开系统的交流电源10
秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e1711
在公共汽车# #装置# #功能# # PCI奇偶校验错误(总线# #设备# #
功能# # PCI奇偶校验错误)
系统PCI BIOS已报告组件发生奇偶校验错误,该组件位于总线# #
设备# #功能# #的PCI配置空间。
请卸下并重置PCIe扩充卡如果问题仍然存在,请参阅”扩充卡故障
排除”。
#插槽上的PCI奇偶校验错误。请检查并清除SEL.(插槽#上PCI奇偶校验错误。请检查并清除SEL。)
系统PCI BIOS已报告位于指定插槽中的组件发生奇偶校验错误。
请卸下并重置PCIe扩充卡如果问题仍然存在,请参阅”扩充卡故障排除”。
e1712
在公共汽车# #装置# #功能# # PCI系统误差(总线# #设备# #功能# # PCI系统错误)
系统PCI BIOS已报告组件发生系统错误,该组件位于总线# #设备# #功能# #的PCI配置空间。
请卸下并重置PCIe扩充卡如果问题仍然存在,请参阅”扩充卡故障排除”。
# PCI插槽上的系统误差。请检查并清除SEL.(插槽# PCI系统错误。请检查并清除SEL。)
系统PCI BIOS已报告组件发生系统错误,该组件位于指定的插槽。
请重新安装扩充卡提升板。请参阅”扩充卡和扩充卡提升板”。如果问题仍然存在,则
示提升卡或系统板出现故障请参阅”获得帮助”。
e1714
未知错误。请检查并清除SEL.(未知错误。请检查并清除SEL。)
系统BIOS已确定系统中存在错误,但无法确定错误来源。
请查看SEL中的详细信息,然后清除SEL。断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e1715
致命的I/O错误(严重I/O错误)审查和明确的选择。(请检查并清除SEL。)
系统BIOS判定系统中存在严重错误。
请查看SEL以了解详细信息,然后清除SEL。断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
芯片
芯片组ierr总线# #开发# #功能# #。请检查并清除SEL.(芯片集ierr总线# #设备# #功能# #。请检查并清除SEL。)
系统BIOS报告了驻留在总线# #,设备# #,功能# #中的芯片集内部错误。
See SEL for more information, and then clear SEL. Disconnect
the AC power of the system for 10 seconds, then restart the
system.
If the problem persists, see "get help"".
E1717
CPU internal error. Review # & clear SEL. (CPU # internal error. Check and clear SEL, please.)
The system BIOS determines that an internal error has occurred in the specified processor.
See SEL for more information, and then clear SEL. Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E171F
PCIe fatal error on Bus Device Function ## ## ## (## ## ## PCIe bus device function fatal error)
BIOS has reported fatal error PCIe components, the components of the PCI configuration space is located in the ## ## function of ## bus equipment.
Please remove and reset the PCIe expansion card. If the problem persists, see the "expansion card troubleshooting"".
PCIe fatal error on Slot Review & clear SEL. (#. slot # PCIe
fatal error. Check and clear SEL, please.)
The system BIOS has reported a fatal PCIe error in the component located in the specified slot.
Please reinstall the expansion card lifting plate. Please refer to the "expansion card" and the "expansion card lift board"". If the problem persists, the upgrade card or system board fails. See "get help."".
E1810
Hard drive fault. Review & clear SEL. ## (hard disk drive ## fault. Check and clear SEL, please.)
The specified hard disk drive is out of order.
Please refer to "hard disk drive troubleshooting."".
E1812
Hard drive removed. Check drive. ## (hard disk drive ## removed. Please check the drive
The specified hard drive has been removed from the system.
For reference only.
E1A11
The PCI Riser Hardware & configuration mismatch. Reconfigure.
(PCI board hardware does not match the configuration. Please reconfigure
PCIe lift plate configuration is incorrect. Some invalid configuration prevents the system from energizing.
Please reinstall the expansion card lifting plate. Please refer to the "expansion card" and the "expansion card lift board"".
If the problem persists, the upgrade card or system board fails. See "get help."".
E1A12
PCI, Riser, not, detected., Check, Riser. (PCI lift plate not detected). Check the lift panel, please
Lose one or two PCIe lifting plates. This will prevent the system from starting.
Please reinstall the missing lifting card. Please refer to "installing expansion card, lifting board 1" and "installing expansion card", lifting board 2".
E1A14
SAS, cable, A, failure., Check, connection. (SAS cable, A fault). Please check the connection
SAS cable A missing or damaged.
Reset cable. If the problem persists, replace the cable.
If the problem persists, see "get help"".
E1A15
SAS, cable, B, failure., Check, connection. (SAS cable, B fault). Please check the connection
SAS cable B missing or damaged.
Reset cable. If the problem persists, replace the cable.
If the problem persists, see "get help"".
E1A1D
Control, panel, USB, cable, not, detected., Check, cable. (USB panel of control panel not detected). Please check the cable
The USB cable connected to the control panel is missing or damaged.
Reset cable. If the problem persists, replace the cable.
If the problem persists, see "get help"".
E2010
Memory not detected. Inspect DIMMs. (memory not detected). Check DIMM, please.)
Memory was not detected in the system.
Install memory or reset memory module. See "installing memory modules" or "system memory troubleshooting."".
E2011
Memory, configuration, failure., Check, DIMMs. (memory configuration failure. Check DIMM, please.)
Memory detected, but memory cannot be configured. Error detected during configuration memory.
Please see "system memory troubleshooting."".
E2012
Memory, configured, but, unusable., Check, DIMMs. (memory is configured, but not available. Check DIMM, please.)
Memory is configured, but not available.
Please see "system memory troubleshooting."".
E2013
BIOS, unable, to, shadow, memory., Check, DIMMs. (BIOS) cannot access shadow memory. Check DIMM, please.)
The BIOS system can not be copied to the memory in the flash
image.
Please see "system memory troubleshooting."".
E2014
CMOS, RAM, failure., Power, cycle, AC. (CMOS, RAM) fault. Please turn off the AC power and turn on
CMOS is out of order. CMOS RAM doesn't work properly.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E2015
DMA, Controller, failure., Power, cycle, AC. (DMA controller failure). Please turn off the AC power and turn on
The DMA controller is out of order.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E2016
Interrupt, Controller, failure., Power, cycle, AC. (interrupt
controller failure). Please turn off the AC power and turn on
The interrupt controller is out of order.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E2017
Timer refresh failure. Power cycle AC. (timer refresh fault). Please turn off the AC power and turn on
Timer refresh fault.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
E2018
Programmable, Timer, error., Power, cycle, AC. (programmable timer error). Please turn off the AC power and turn on
Programmable interval timer error.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "get help"".
奇偶
奇偶校验错误。动力循环的AC.(奇偶校验错误。请关闭交流电源再打开。)
奇偶校验错误。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e201a
系统故障。动力循环的AC.(上故障。请关闭交流电源再打开。)
SiO出现故障。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e201b
键盘控制器错误。动力循环的AC.(键盘控制器错误。请关闭交流电源再打开。)
键盘控制器故障。(键盘控制器故障。)
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e201c
初始化失败。动力循环的AC.(SMI初始化失败。请关闭交流电源再打开。)
系统管理中断(SMI)初始化失败。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e201d
关机测试失败。动力循环的AC.(关闭检测程序失败。请关闭交流电源再打开。)
BIOS关闭检测程序失败。
断开系统的交流电源10秒,然后重新启动系统。
如果问题仍然存在,请参阅”获得帮助”。
e201e
内存后测试失败。Check DIMMs。(后内存检测失败。请检查DIMM。)
BIOS内存检测失败。
请参阅”系统内存故障排除”。
如果问题仍然存在,请参阅”获得帮助”。
E2020
cpu配置失败。请检查屏幕信息。(CPU配置失败。请检查屏幕信息。)
处理器配置失败。
请查看屏幕上的具体错误信息请参阅”处理器故障排除”。
E2021
不正确的内存配置。请参阅用户指南。(内存配置不正确。请参阅用户指南。)
内存配置不正确。
请查看屏幕上的具体错误信息请参阅”系统内存故障排除”。
e2022
岗位普遍失败。请检查屏幕信息。(后期间一般故障。请检查屏幕信息。)
视频后出现一般故障。
请查看屏幕上的具体错误信息。
e2023
BIOS无法镜像内存。Check DIMMs。(BIOS无法镜像内存。请检查DIMM。)
由于内存模块发生故障或内存配置无效,系统BIOS无法启用内存镜
像功能。
请参阅”系统内存故障排除”。
e2110
在DIMM # #多位错误。安装DIMM。(DIMM # #上多位错误。请重置
DIMM。)
The memory module slot "##" has occurred many errors (MBE).
Please see "system memory troubleshooting."".
E2111
SBE log disabled on DIMM Reseat DIMM. (DIMM ##. disabled ## on SBE log. Reset DIMM, please.)
System BIOS has disabled memory unit error (SBE) records, and no more SBE will be recorded before rebooting the system. "Memory module ##" on behalf of BIOS instructions.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "system memory
troubleshooting."".
E2113
Mem mirror OFF on DIMM & Power cycle AC. ## ##. (DIMM ## and ## memory mirroring on off. Please turn off the AC power and turn on
Since the system BIOS determines too many errors in half of the mirror image, memory mirroring has been disabled. The memory module of the ## and ## "on behalf of BIOS instructions.
Disconnect the AC power of the system for 10 seconds, then restart the system.
If the problem persists, see "system memory
troubleshooting."".
I1910
Intrusion, detected., Check, chassis, cover. (intrusion detected). Please check the chassis cover).
The system cover has been removed.
For reference only.
I1911
LCD, Log, Full., Check, SEL, to, review, all, Errors. (LCD log is full. Please check SEL to see all errors
LCD overflow information. LCD can display up to ten error messages at most. The eleventh message instructs the user to check the SEL for details of the event.
View SEL for event details.
Disconnect the AC power of the system for 10 seconds, or clear the SEL.
I1912
SEL full. Review & clear log. (SEL is full). Please check and clear the logs
The event logged on the SEL is full and cannot record anything else.
See the details in SEL, and then clear the SEL.
W1228
RAID Controller battery capacity < 24hr. (the battery capacity of the RAID controller is less than 24 hours)
Forewarned that the RAID battery has only less than 24 hours of electricity left.
Charge the RAID battery to allow the battery to remain in excess of 24 hours.
If the problem persists, replace the RAID battery. See
"installing RAID batteries."".
W1627
Power, required > PSU, wattage., PSU, and, config., Check (the required power is greater than PSU power. Please check PSU and configuration
System configuration requires power greater than the power available from the power supplies.
Turn off the system power, reduce the hardware configuration, or install a higher power device, and then restart the system.
W1628
Performance, degraded., Check, PSU, and, system,
configur-ation. (performance degradation). Please check PSU and system configuration
System configuration requires greater power than the power supply, but can be guided if throttling is used.
Turn off the system power, reduce the hardware configuration, or install a higher power device, and then restart the system.
DELL servers, workstations, storage, full range