D RJ45 A DC12V
C RS485
B VIDEO IN
RJ-45 A1 B1 A2 B2 VIDEO IN DC12V
Red: CH1 RS485+/A1
Black:CH1 RS485- /B1
Yellow:CH2 RS485+ /A2
Green:CH2 RS485- /B2
DC12V
RS-485
RS-485
VIDEO IN
RJ-45
Character Style
RJ-45
Inage Style
Figure 1
44
Install and connect
A2 B2
Keyboard
Speed Dome
RS485A+ RS485A-
......
Figure 2
Figure 3
RS485A+ RS485B-
DVR
A1 B1
RS485A+ RS485B-
A2B2
RS485-IN RS485-OUT
Keyboard
Speed Dome
Keyboard Speed Dome
Figure 4
RS485A+ RS485A-
DVR
RS485A+ RS485B-
A2 B2
JaRa 2115B
Distributor
1200m
RS485 BUS
1# 2# 3# 4#
A2 B2
1200m
Figure 5
16 pictures
divisions
Figure 6
Figure 7
JaRa2115B
1 # 2 # 3 # 4 # 5 # 6 # 7 # 8 # 9# 10#11#12# 13# 14#15#16#
A2 B2
RS485 BUS
1 # 2 # 3 # 4 # 5 # 6 # 7 # 8 # 9# 10#11#12# 13# 14#15#16#
1200m
JaRa2115B
Distributor
JaRa2115B
Distributor
JaRa2115B
Distributor
JaRa2115B
Distributor
JaRa2115B
Distributor
1200m
Picture Control Keyboard
Monitor
JaRa2115B
Distributor
JaRa2115B
Distributor
JaRa2115B
Distributor
JaRa2115B
Distributor
JaRa2115B
Distributor
Video
frequency
transmission
line
Speed Dome
Speed Dome
Baud Rate Maximum Transmitting Distance
1200 Bps 2400m
2400 Bps 1800m
4800 Bps 1200m
9600 Bps 800m
19200 Bps 200m
Function
Panel introduce
Character Control Keyboard
Setup demo camera or decoder ID address range0~255.
Control to multi-function of demo camera, such as:
menu, focus, white balance.
control the demo camera to multi-speed.
Save preset position of demo camera, setup shot about
the preset position. The keyboard can setup 8 shots, each
shot can save 16 preset position.
Two control mode: manual mode and auto mode.
Control zoom, focus and iris of demo camera by
manual mode.
Picture Control Keyboard
Picture Control Keyboard can show image, and the
other function are same as the Character Control Keyboard.
It can work with and control it at long
distance.
1.front panel introduce (figure 8/8-1)
16 pictures divisions
Figure 8 Character control keyboard panel
figure 8-1 Image control keyboard panel
CHANGE CAMERA ID
Camera ID N
PELCOD 2400
Camera Id 000
Baud rate(default)
4800
9600
9600
9600
9600
9600
9600
protocol
KALATEL
VCLDOME
REDAPPLE
HTSCAM
SAMSUNG
SANTACHI450
SANTACHI650
Protocol Baud rate(default)
PELCO-D 2400
PELCO-P 9600
PELCO-P 4800
VIDO-BO1 9600
LILIN 9600
ALEC 4800
HD600 9600
TOTA 4800 VICON 4800
2. Control keyboard support Protocol and baud rate.
List1:Protocol list and baud rate list.
NOTE: Press F1 +61+ON, F1 +62+ON to change protocol
and baud rate, about content show on List 2.
3. Operation introduce
The keyboard controller must connected to demo camera
and right setup ID address before operation. Then turn on
power that it will display at bellow:
PELCOD: current protocol
2400: current baud rate
000: current demo camera ID
3.1 Setup demo camera id address
[CAMERA]+[N]+[ENTER]Display:
FUNCTION MENU
CHANGE PROTOCOL
PRESET FUNCTION
PRESET N
PRESET FUNCTION
PRESET N
PRESET FUNCTION
CALL N
SHOT OPERATION
Track 01 Sum 07
EDIT SHOT
NO.:01 Point:01
EDIT SHOT
NO.:01 Speed:02
EDIT SHOT
NO.:01 Time:03
SHOT OPERATION
Running N SHOT
Scan Operation
Auto Running
N define
Numb
er
controlitem
[F1]+N+[ON] [F1]+N+[OFF]
0 Camera power
supply
Turn on Turn off
1 Backlight
compensate
ON OFF
2 Zero illumination ON OFF
3 menu ON OFF
4 Digital zoom ON OFF
5 Camera reset Returns to the level
which wasset by the
manufacturer for
shipment
6 focus Auto manual
7 iris Auto manual
8 Auto manual
9 indoor outdoor
10
White balance
ATW One Push WB
11 Color/black-whit
e
Color white
12 Less than 180 low
speed
more than 180 low
speed
13 Less than 180
speed
more than 180 mid
speed
14
Speed of line
scan direction of
line scan
Less than 180 high
speed
more than180 high
speed
15 Keyboard
backlight
ON OFF
61 Change protocol Enable the function disable the function
62 Change baud
rate
Enable the function disable the function
PRESET FUNCTION
CALL N
PRESET FUNCTION
DWELL TIME N
PRESET FUNCTION
RUN SPEED N
.
SPECIAL FUNCTION
AUTO:
CLEAR IN:255--OFF
RUN SPEED:255
PRESET FUNCTION
DWELL TIME:255
d)Save step speed in preset position, press [N]+[ENTER].
2 Call preset position: [CALL]+[N]+[ENTER]
3 Clear all preset position:[PRESET]+[255]+ [EN-
TER]+[255]+[OFF]
a) Press [PRESET]+[255] Display:
b) Press [ENTER]+[255] Display:
Note: input 255, press [OFF] It will clear all preset
position.
4.Setup alarm: [AUTO]+[ON]+[N]+ [ENTER]
a) Press [AUTO] Display:
b) Press [ON]+[N] Display:
Alarm Polling
ALARM NO.:N
Note: N---PIN's input, range: 0~255
(Actual could not use to be 255) The key completes PIN
after [ ENTER ] the establishment.
5 Clear setup alarm: [AUTO]+[OFF]
6 Run shot: [SHOT]+[N]+ [ENTER] Display:
Note:
1) N=000 sets up 1, 2,3,4 group group and runs 1~16
preset position.
2) N=001 set up 1 group group and run 1~4 preset position.
3) N=012 sets up 1, 2 group group and runs 1~8 preset
position.
4) N=234 sets up 2,3,4 group group and runs 5~16 preset
position.Commonly : First group group comprises 1,2,3,4
presetposition Second group group comprises 5,6,7,8 preset
position Third group group comprises 9,10,11,12 preset
position.
Fourth group group comprises 13,14,15,16 preset position
If differ, please refer to speed dome user manual .
7 1 Setup menu: [CALL]+[95]+ [ENTER]
7 2 Clear menu: press [CALL]+[95]+ [ENTER] again.
SHOT OPERATION
SHOT : N
Note: N---PIN's input, range: 0~255.
(Actual could not use to be 255) The key completes PIN
after [ ENTER ] the establishment.
5 Clear setup alarm: [AUTO]+[OFF]
6 Run shot: [SHOT]+[N]+ [ENTER] Display:
Note:
1) N=000 sets up 1, 2,3,4 group group and runs 1~16
preset position.
2) N=001 set up 1 group group and run 1~4 preset position.
3) N=012 sets up 1, 2 group group and runs 1~8 preset
position.
4) N=234 sets up 2,3,4 group group and runs 5~16 preset
position.Commonly : First group group comprises 1,2,3,4
presetposition, Second group group comprises 5,6,7,8 preset
position; Third group group comprises 9,10,11,12 preset
position,Fourth group group comprises 13,14,15,16 preset
position.
If differ, please refer to speed dome user manual .
7 1 Setup menu: [CALL]+[95]+ [ENTER]
7 2 Clear menu: press [CALL]+[95]+ [ENTER] again.
PELCOD * 9600
Camera ID N
Picture Control Keyboard can show image, and other
functions are same as the Character Control Keyboard. It
can work with multivision plus processor and control it at
long distance. Press the key A/B once to switch to image
processor mode to normal mode. on image processor mode,
showing as bellow:
Display * between protocol and baud rate. Press
A/B again to cancel image processor mode. On image
processor mode: Press [ENTER]+0+[ENTER], into image
processor functional menu.
Press [ENTER]+N+[ENTER], into the N input video,
N=1-16 With [CALL/ENTER], [AUTO/EXIT], [ZOOM],
[FREEZE], [one image] key ,[four image] KEY, [nine image]
KEY and [sixteen image] key, other operation can be done.
The key function is same as image processor panel.
The function and the operation refer to manual of image
processor.
Specification list
Screen display 16x2 character 3.5'LCD color picture
Control object High speed ball , general ballPTZ decode High speed ball ,general ball
PTZdecode,16picture processor
Protocol PELCO-D , PELCO-P
ALEC , SAMSUNG
VIDO-B01 , NEON
HTSCAM
HD600 , TOTA
KALATEL , VCLDOME
REDAPPLE ,SANTACHI450
SANTACHI650 ,VICON
Baud rate 1200bps,2400bps,4800bps,9600bps,19200bps
Out channel 2 channel
Communication distance Max :2400m
Operation Temperature -10
Power DC12V/1A DC12V/1A
1.Lighting proof and surge signal proof The product
adopts TVS lightning proof technology to prevent from
damage by lightning strike below 1500 W and impulse
signals such as surge; but it is also necessary to abide by the
following precautions to ensure electrical safety based on
practical circumstances:
Keep the communication cables at least 50 M away
from high voltage equipment or cables.
Make outdoor cable laying-out under eaves as possible
as you can.
In open area shield cables in steel tube and conduct a
single Point ground to the tube. Trolley wire is forbidden in
such circumstances.
In strong thunderstorm or high far adic zone (such as
high voltage transformer substation), extra strong lightning
proof equipment must be installed.
Take the building lightning proof requirements into
account to design the lightning proof and grounding of
outdoor equipment and cable laying-out in accordance with
the national and industrial standards.
The system must be grounded with equal potentials.
The earth ground connection must satisfy the anti-
interference and electrical safety requirements and must not
short circuited with high voltage electricity net. When the
system is grounded separately, the resistance of down
conductor should be 4 and the sectional area of down
2conductor should be 25mm .
1.Lighting proof and surge signal proof
The product adopts TVS lightning proof technology to
prevent from damage by lightning strike below 1500 W and
impulse signals such as surge; but it is also necessary to
abide by the following precautions to ensure electrical safety
based on practical circumstances:
Keep the communication cables at least 50 M away
from high voltage equipment or cables.
Make outdoor cable laying-out under eaves as possible
as you can.
In open area shield cables in steel tube and conduct a
single Point ground to the tube. Trolley wire is forbidden in
such circumstances.
In strong thunderstorm or high far adic zone (such as
high voltage transformer substation), extra strong lightning
proof equipment must be installed.
Take the building lightning proof requirements into
account to design the lightning proof and grounding of
outdoor equipment and cable laying-out in accordance with
the national and industrial standards.
The system must be grounded with equal potentials.
The earth ground connection must satisfy the anti-
interference and electrical safety requirements and must not
short circuited with high voltage electricity net. When the
system is grounded separately, the resistance of down
conductor should be 4 and the sectional area of down
2conductor should be 25mm .
2525
Baud Rate Maximum Transmitting Distance
1200 Bps 2400m
2400 Bps 1800m
4800 Bps 1200m
9600 Bps 800m
19200 Bps 200m
2.RS485 bus basic knowledge
1)Characteristics of RS485 Bus As specified by RS485
standards, RS485 Bus is of half -duplexed data transmission
cables with characteristic impedance as 120Ù. The maximum
load capacity is 256 nit loads (including main controller and
controlled equipment).
2.)Transmission distances of RS485 Bus When user selects
the 0.56mm 24AWG twisted pair wires as data transmis-
sion cable, the maximum theoretical transmitting distances
are as follows:
3)connection and termination resistor
a)The RS485 standards require a daisy-chain connection
between the equipment. There must be termination resistors
with 120Ùimpedance at both ends of the connection. (refer to
Figure 1).Please refer to Picture 2 for simple connection.
D should exceed 7m.
1#
6# Equipment
15#
32#
Figure3
1#
2#
16#
120
120
120
A+
B-
Figure4
b)The connection of 120Ù termination resistor: See to
single system connection. 4)In some circumstances user
adopts a star configuration in practical connection. The
termination resistors must be connected to the two equipment
that are farthest away from each other, such as equipment 1#
and 15# in figure3. As the star configuration is not in confor-
mity with the requirements of Rs485 standards, problems
such as signal reflections, lower anti-interference perfor-
mance arise when the cables are long I the connection. The
reliability of control signals is decreased with the phenomena
that the dome does not respond to or just responds at intervals
to the controller, or does continuous operation without stop
(refer to figure4)
Ò³Ãæ 1
Ò³Ãæ 2
Ò³Ãæ 3
Ò³Ãæ 4
Ò³Ãæ 5
Ò³Ãæ 6
Ò³Ãæ 7
Ò³Ãæ 8
Ò³Ãæ 9
Ò³Ãæ 10
Ò³Ãæ 11
Ò³Ãæ 12
Ò³Ãæ 13
Ò³Ãæ 14
Ò³Ãæ 15
Ò³Ãæ 16
Ò³Ãæ 17
Ò³Ãæ 18
Ò³Ãæ 19
Ò³Ãæ 20
Ò³Ãæ 21
Ò³Ãæ 22
Ò³Ãæ 23
Ò³Ãæ 24
Ò³Ãæ 25
Ò³Ãæ 26
Ò³Ãæ 27
Ò³Ãæ 28
Ò³Ãæ 29
Ò³Ãæ 30
Ò³Ãæ 31
Ò³Ãæ 32