GNF-722-10(0) A4(210×297)mm(주)제니컴
Approval Sheet
SMD type UV Detector
Model : GUVA-S10GD
File No. :
Date : 2005. 6
SalesQ.A.
PREPARED BY : Genicom Co. Ltd. APPROVED BY :
GNF-722-10(0) A4(210×297)mm(주)제니컴
SPECIFICATIONS
SMD Type UV Detector
Model : GUVA-S10GD
TEL:+82-42-472-7462 FAX:+82-42-472-7459
5F, Daehan Building, #1018 Dunsan-dong, Seo-gu, Daejeon 302-120, Korea
GNF-722-10(0) A4(210×297)mm(주)제니컴
■ Features
■ Fabricated using a Gallium-Nitride material system.
■ Visible Blind
■ No filters required
■ Photovoltaic mode
■ UV transparent quartz window
■ 3.5 ×2.8 ×1.8 (L×W×H) small size surface mount type
■ Taping : 8mm tape with 2,000EA/reel
■ Applications
■ Sunlight exposure meter, Ozone monitors
■ Blood analyzers, Flame sensor
■ Spectrophotometer and UV source monitors
■ Outline Diagrams and Dimensions
AuWire④
AgPaste②
GaN/Al2O3UV Detector Chip③
QuartzWindow⑤
PPAPlastic PKG①
MaterialItemsNo.
Figure 2. Component and Its Material
Figure 1. Outline Diagrams and Dimensions
①
②
③
④
⑤
Unit : [mm]
GNF-722-10(0) A4(210×297)mm(주)제니컴
Test ConditionsUnitMaxMinSymbolItem
V5VRReverse Voltage
℃85-30TopOperation Temperature
℃90-40TsStorage Temperature
Soldering Temperature 10 sec℃260Tsol
■ Absolute Maximum Ratings
Test ConditionsUnitMaxTypMinSymbolItem
A mm20.076Sensitivity Area
Spectral detection Range
Peak Responsivity
Photo Current
Dark Current
Monochromator Scannm370200λ
Genicom’s standardnA2720Iph
λp=350nm, VR=0VA/W0.15Rp
Id VR = 0VnA10.05
■ Electro-Optical Characteristics ( at Ta = 25℃)
■ Characteristic Graphs ( at Ta = 25℃)
Figure 3. Typical Spectral Responsivity
200 220 240 260 280 300 320 340 360 380 400
10-4
10-3
10-2
10-1
100
R
es
po
ns
iv
ity
(A
/W
)
Wavelength (nm)
GNF-722-10(0) A4(210×297)mm(주)제니컴
■ Reliability
Test ConditionsUnitMaxMinSymbolItem
VR = 1VnA1-IdDark Current
VR = 1VnAI.S.V × 1.1I.S.V × 0.9IphPhoto Current
■ A Criterion for Judging
■ Test Results
-0100
Height : 152cm, 20 cycles
(Ground Metal Table)
Drop Test
-030110℃, 85% RH, 2 atm, 10hrsPCT
MIL-STD-7500100-40℃ ~ 25℃ ~ 85℃ ~ 25℃10 cyclesTemp. Cycling
-0100UVI = 100(UVB lamp), 500hrs UV Exposure
JIS-C-7021010060oC, 95% RH, 1000hrs
High Temperature &
High Humidity Storage
JIS-C-70210100-40oC, 1000hrsLow Temperature Storage
JIS-C-7021010085oC, 1000hrsHigh Temperature Storage
JESD22 B-106A0100T.sol=260±5℃Dwell time=10±1secSoldering Resistance
JESD22 A-114B030Class 1A : 3500V, -300V
ESD (HBM)
(Resistance : 1500Ω,
Capacitance : 100pF)
StandardizationFailureS/STest ConditionsItem
GNF-722-10(0) A4(210×297)mm(주)제니컴
10 sec.
Max.
Within 2min
50 sec.
MAX.
Max: 260℃
150
100
Te
m
pe
ra
tu
re
(℃
)
Time (sec.)
■ Reflow Soldering Profile
■ Soldering Pattern
Unit : [mm]
Figure 4. Recommended Soldering Pattern
Figure 5. Recommended Reflow Soldering Profile
■ Manual Soldering Conditions
■ Temperature : Max. 260oC
■ Time : Max. 10 sec.
■ Caution : You must put to earth and shield the package from ESD damage.
(ex.: wrist strap or anti-electrostatic gloves )
■ Definition of Lot No.
【 EX.】: UAG 0506 – 001
UAG : Product Model (UVA Detector with quartz window)
0506 : Product Year and Month
001 : Consecutive number
2.3 ± 0.1
1.7 ± 0.1 1.3 ± 0.11.3 ± 0.1
GNF-722-10(0) A4(210×297)mm(주)제니컴
■ Taping
Figure 6. Standardization of Taping
Figure 7. Diagram and Standardization of Reel
■ Quantity : Max. 2000EA/reel
■ Label : Model Name, Lot Number, Quantity
■ The packing materials such as reel, carrier tape, cover tape and shielding bag are antistatic.
GNF-722-10(0) A4(210×297)mm(주)제니컴
■ Packing
Model No. : GUVA-S10GD
Q'TY : 2,000 EA
Lot No. : UAG0506-001
40±1
70±1
10±1UV Detector
Model No. : GUVA-S10GD
Q'TY : 2,000 EA
Lot No. : UAG0506-001
40±1
70±1
10±1UV Detector
19±1
8±1
W
D
H
■ Reel
■ Al Shielding Bag
■ Outer Box
Size : W x D x H = 280 x 300 x 250 [mm]
C/T No.
EAQuantity
Order No.
Model No.
Name of Goods
GNF-722-10(0) A4(210×297)mm(주)제니컴
■ Cautions For Use UV Detector
-. In case of cleaning, use only IPA.
-. To be kept under clean environment.
For more than 3months storage, put in sealed containers
-. It should be soldered within 7days after opening a seal.
-. Use a wrist strap or anti-electrostatic gloves for handling, to protect from a static electricity
and surge
-. If you operate it over the absolute maximum ratings, that may cause a permanent damage.
-. It can be damaged by working environment which is not shielded from a static electricity.
-. Damaged products show unusual characteristics such as large leakage current, or do not work.
GNF-722-10(0) A4(210×297)mm(주)제니컴
■ Appendix 1. QC Flowchart
Incoming Inspection
(UV Detector chip, Package, Glass)
Die / Wire Bond
Shipping
Taping
Glass Gluing (N2 chamber)
Performance Test 2
Visual Inspection
Trimming
Final Visual Inspection
Incoming Inspection
(Substrate)
Ohmic contact formation
Pad metal formation
Schottky contact formation
Epi wafer Growth
Test of Epi wafer
Performance Test 1
Visual Inspection
Scribe / Break
GNF-722-10(0) A4(210×297)mm(주)제니컴
TEL:+82-42-472-7462 FAX:+82-42-472-7459
Daehan Building 5F, #1018 Dunsan-dong, Seo-gu, Daejeon 302-120, Korea