消防气体灭火系统每季检查表 厂区(Site): 防护区域(Protected Room or Area): 设备代号Equipment NO 项次 Item 检查内容 (Questions) 危害风险 (Hazardous Risk) 异常状况改善措施 (Explain) A-1 防护区域大小与用途无变更 (There are no changes in size or type of hazard protected) □(0) □(1) □(2) □(N)   A-2 检查各系统组件无...
消防气体灭火系统每季检查表
厂区(Site): 防护区域(Protected Room or Area): 设备代号Equipment NO 项次 Item 检查内容 (Questions) 危害风险 (Hazardous Risk) 异常状况改善措施 (Explain) A-1 防护区域大小与用途无变更 (There are no changes in size or type of hazard protected) □(0) □(1) □(2) □(N)   A-2 检查各系统组件无明显受损 (Check system components for signs of physical damage) □(0) □(1) □(2) □(N) A-3 检查高压管及挠性街头无受损 (Check hoses and flexible connections free from damage) □(0) □(1) □(2) □(N) A-4 启动钢瓶压力表指数是否正常 (The pressure gauges of start cylinder indicate normal) □(0) □(1) □(2) □(N) A-5 所有阀(安全阀、选择阀、逆止阀)无损害(All valves free from physical damage) □(0) □(1) □(2) □(N) A-6 气体钢瓶无损害及明显泄漏 (The Gas cylinder free from damage and signs of leakage) □(0) □(1) □(2) □(N) A-7 标示牌仍在且无损坏(Placards are in place and free from damage) □(0) □(1) □(2) □(N) A-8 喷嘴完好无损坏(The nozzles free form physical damage) □(0) □(1) □(2) □(N) A-9 喷放时开口门能自动闭锁 (Doors are self-closing or close automatically for carbon dioxide discharge) □(0) □(1) □(2) □(N) A-10 系统控制盘无损害(The local control panel free from damage) □(0) □(1) □(2) □(N) A-11 配管、固定架良好(The pipe, hanger/seismic bracing appear attached and secure) □(0) □(1) □(2) □(N) A-12 电气配管、配线及连结无裸露 (The connections of electric system free from damage) □(0) □(1) □(2) □(N) B-1 进行系统控制盘仿真测试(The system test) □(0) □(1) □(2) □(N) B-2 测试前安全隔离已执行(The safety procedure have been done before testing) □(0) □(1) □(2) □(N) B-3 感烟探测器作动正常(Smoke detectors are operating normally) □(0) □(1) □(2) □(N) B-4 感温探测器作动正常(Heat detectors are operating normally) □(0) □(1) □(2) □(N) B-5 控制系统之双回路作动正常 (Two zones type of detection for system operation is normal) □(0) □(1) □(2) □(N) B-6 紧急启动开关作动正常(Manual Discharge is operating normally) □(0) □(1) □(2) □(N) 项次 Item 检查内容 (Questions) 危害风险 (Hazardous Risk) 异常状况改善措施 (Explain) B-7 紧急停止开关作动正常(Emergency shut down button is operating normally) □(0) □(1) □(2) □(N)   B-8 手动/自动切换开关作动正常(Manual/Automatic switch is operating normally) □(0) □(1) □(2) □(N) B-9 压力开关作动正常(Pressure switch is operating normally) □(0) □(1) □(2) □(N) B-10 火警警铃鸣动正常(Bells are operating normally) □(0) □(1) □(2) □(N) B-11 声光报警器作动正常?(Horns and strobes are operating normally) □(0) □(1) □(2) □(N) B-12 语音广播喇叭作动正常?(Loudspeakers are operating normally) □(0) □(1) □(2) □(N) B-13 气体释放警示灯作动正常?(Discharge lights are operating normally) □(0) □(1) □(2) □(N) B-14 时间延迟装置作动正常(Time Delay device is operating normally) □(0) □(1) □(2) □(N) B-15 电磁阀作动正常(Discharge electromagnetic valve is operating normally) □(0) □(1) □(2) □(N) B-16 所有阀(安全阀、选择阀、逆止阀)作动正常(All valves are operating normally) □(0) □(1) □(2) □(N) B-17 CO2排气装置及闸门动作正常 (The exhaust fan and damper of CO2 system is operating normally) □(0) □(1) □(2) □(N) B-18 CO2排气装置手动开关作动正常 (The manual switch of CO2 exhaust system is operating normally) □(0) □(1) □(2) □(N) B-19 CO2排气装置排气量正确(The flow capacity of CO2 exhaust system is normal) □(0) □(1) □(2) □(N) B-20 测试时空调系统是否联动正确 (The air condition system is operating normally during testing) □(0) □(1) □(2) □(N) C-1 电力供应正常:检查线路槽、回路断路器、保险丝、隔离装置 (Power supply is normal: Check routing, circuit breakers, fuses, Disconnects) □(0) □(1) □(2) □(N) C-2 紧急发电机能实时供应(Emergency generator can supply immediately) □(0) □(1) □(2) □(N) D 防灾中心是否收到讯号(Did alarm supervisory company receive signal:) □(0) □(1) □(2) □(N) E 警报面盘是否复归 (Did alarm panel reset:) □(0) □(1) □(2) □(N) F 警报面盘无异常讯号(Alarm panel clear:) □(0) □(1) □(2) □(N) G 检查完系统回复正常使用(Systems left in service) □(0) □(1) □(2) □(N)        
/
本文档为【消防气体灭火系统每季检查表】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索