ICS 75.010
E 11
备案号:8192-2001 L丫
中华人民共和国石油天然气行业标准
SY/I' 5523-2000
油气田水
方法
Analysis for oil and gas field water
2000一12一25发布 2001一06一01实施
国家石油和化学工业局 发 布
SY/T 5523- 2000
目 次
前 言 ···············································································································⋯⋯ N
1 范围 ···············································································································⋯⋯ 1
2 引用标准 ·········································································································⋯⋯ 1
3 取样 ···············································································································⋯⋯ 1
4 试剂、溶液和材料 ·····························································································⋯⋯ 1
5 仪器和设备 ······································································································⋯⋯ 4
6 物理性质的测定 ································································································⋯⋯4
7 抓离子含量的测定 ····························································································⋯⋯5
8 碳酸根、碳酸氢根、氢氧根离子含量的测定 ····························································⋯⋯7
9 硫酸根离子含量的测定 ····················································································⋯⋯‘·9
10 镁、钙、银、钡离子含量的测定 ········································································⋯⋯10
11 碘、澳离子含量的测定 ····················································································⋯⋯15
12 滴定法测定硼的含量 ·······················································································⋯⋯16
13 钠、钾离子含量的计算方法 ··············································································⋯⋯ 18
14 油气田水的分类 (苏林分类)................................................................................. 18
附录A(标准的附录) 溶液的配制和标定 ····················································。··········⋯⋯ 20
附录B(标准的附录) 温度系数
········································································⋯⋯ 23
附录C(标准的附录) 不同温度下纯水的密度值 ······················································⋯⋯ 24
附录D(提示的附录) 用不确定度表述的平行样品分析结果的质量要求 ························⋯⋯ 25
SYPP 5523-2000
前 言
本标准是对SY 5523-92(油田水分析方法》进行的修订。修订的主要内容有:
1.本次修订主要对原标准3.3, 6.1, 6.2, 7.4, 8.1, 9.1, 9.2, 9.3, 10.6, 11.3进行了修
改。
2.删除了原标准12.20
3修改了碳酸根的计算公式。
4修改了离子色谱分析方法。
5.增加了原子吸收分析方法。
6.增加了采用不确定度表述分析质量要求的方法,作为提示的附录。
7.对原标准中个别与现标准编写
不符合的文字和符号进行了修改。
本标准的附录A、附录B和附录C都是标准的附录。
本标准的附录D是提示的附录。
本标准自生效之日起,同时替代SY 5523-920
本标准由中国石油天然气集团公司提出。
本标准由石油地质勘探专业标准化委员会归口。
本标准起草单位:中国石油西南油气田分公司勘探开发研究院。
本标准主要起草人 彭 英 张 鉴 苏忠锐 司徒明 王兰生
本标准于1992年11月首次发布,本次为第一次修订。
中华人民共和国石油天然气行业标准
SY/1' 5523-2000
油气田水分析方法 代替 SY 5523-92
Analysis for oil and gas field water
范围
本标准
了油气田水分析方法和质量要求。
本标准适用于石油、天然气勘探和开发中的油气田水分析。
2 引用标准
下列标准所包含的条文,通过在本标准中引用而构成为本标准的条文。本标准出版时,所示版本
均为有效。所有标准都会被修订,使用本标准的各方应探讨使用下列标准最新版本的可能性。
SY/1' 5982-94 原子吸收光谱法测定油气田水中金属元素
3 取样
3.1取样前应先将井中的地表水、泥浆水排完。
3.2试油过程应每8h测一次氯离子含量,连续三次氯离子含量不变时才能取样。
3.3将容积不小于1L、洗净的玻璃瓶用水样洗涤三次,然后盛满水样并密封。
4试剂、溶液和材料
4.1 试剂
试剂包括:
— 甘露醇,分析纯;
— 碘化钾,分析纯;
— 氯酸钾,分析纯;
一一饱和澳水,分析纯;
— 磷酸,分析纯;
— 冰乙酸,分析纯;
— 三氯甲烷 (氯仿),分析纯;
— 硝酸,分析纯;
— 硫酸,分析纯;
— 氯化按,分析纯;
— 氨水,分析纯;
.— 铬酸钾,分析纯;
— 甲基橙,分析纯;
— 酚酞,分析纯;
— 甲基红,分析纯;
— 铬黑T,分析纯;
— 钙试剂,分析纯;
国家石油和化学工业局2000一12一25批准 2001一06一01实施
SYPP 5523-2000
— 乙酸铁,分析纯;
— 氯化钠,分析纯;
— 氧化锌,优级纯;
— 氯化钾,优级纯;
— 碳酸钠,分析纯;
— 无水碳酸钠,优级纯;
— 碳酸氢钠,分析纯;
— 乙二胺四乙酸二钠 (EDTA),分析纯;
— 重铬酸钾,优级纯;
— 硫代硫酸钠,分析纯;
— 氢氧化钠,分析纯;
— 苯二甲酸氢钾,优级纯;
— 抓气,P(} = 99.9%;
— 高锰酸钾,分析纯。
4.2 溶液
4.2.1硝酸溶液:PHN03 =50%0
4.2.2盐酸溶液:Tea=50%o
4.2.3盐酸溶液:wHa=1%o
4.2.4乙酸溶液:CG3C00H=OAm01几。
4.2.5碳酸钠溶液:wr-2003 = 0.05%,
4.2.6 氢氧化钠溶液:cvN}OH=4%; wr.-1=20%;wN.m =0.5% o
4.2.7氨水:Prix,-r}0= 50%.
4.2.8 氢氧化钡溶液:饱和。
4.2.9氯化钡溶掖:Wad=10%0
4.2.10硫酸钠溶液:-Ne2s0, = 5%,
4.2.11铬酸钾溶液:“ }CK20'0}一0.07mo1/Lo
4.2.。 乙酸按溶液:W at}00-i4 =2%.
4.2.13乙酸钠溶液:mavDoN,=12%,
4.2.14乙酸钠溶液:ccj3cDONa=3mo1/Lo
4.2.15 甲酸钠溶液:-H00oraa=10%,用时现配。
4.2.16乙酸锌溶液:w(ax3000)za=10% u
4.2.17次氯酸钙溶液:-r}(co),二20%0
4.2.18 次氯酸钠溶液:制备方法见附录A(标准的附录)。
4.2.19碳酸锌悬浮液:将log碳酸锌溶于200mL水中,将此溶液与loomL氢氧化钠溶液
汇W。 =10%]混合。
4.2.20
4.2.21
4.2.22
4.2.23
4.2.24
注:
4.2.25
一 2
硫酸品红溶液:将1g品红溶于1L水中,加亚硫酸钠至溶液退色为止。
四径基葱醒硫酸溶液:。四径基惠醒破酸二0.01%.
苯酚乙醇溶液:甲苯阶乙醇=20%,将100g苯酚溶于100n止无水乙醇中,加200n止水,摇匀。
重铬酸钾溶液:wK2G20,一10%;
试验用水均为去离子水或重蒸馏水。
91为溶液的体积分数;。为溶液的质量分数;。为溶液的浓度。
离子色谱淋洗液。
SY/T 5523-2000
a)阳离子淋洗液:
甲烷磺酸:c(}}So,H为15--35mmol/L;
硫酸:cf}gpe为5一lommol/L.
b)阴离子淋洗液:
Na2CO3 " NaHC03二元淋洗液浓度分别为2.Ommol/L和3.Ommol/L;
NaOH; cNOH为3一5mmol/Lo
4.2.26 缓冲溶液。
氨水一氯化按缓冲溶液:pH-10,称取27g氯化钱溶于水中,加浓氨水197mL,再用水冲稀至
1L;
乙酸一乙酸按缓冲溶液:pH--5.9,称取30g乙酸钱溶于l00mL水中,加1ML冰乙酸摇匀。
4.2.27 标准溶液。
a)盐酸标准溶液:cr,p=0.05mol/L,制备见附录A(标准的附录),有效期两个月。
b)硝酸银标准溶液:CAgNO,二0.05mol/L,制备见附录A(标准的附录),有效期两个月。
c) EDTA标准溶液:C=A二0.0125mol/L,制备见附录A(标准的附录),有效期两个月。
d)硫代硫酸钠标准溶液:CN0eseo3=0.03mol/L, cN.Ao3=O.Olmol/L,制备见附录A(标准的附
录),有效期两个月。
e)氢氧化钠标准溶液:cN,GH= 0.05mol/L,制备见附录A(标准的附录),有效期两个月。
f)氟离子标准溶液:应符合BW3065的规定。
g)氯离子标准溶液:应符合GBW (E) 080269的规定。
h)澳离子标准溶液:应符合BW3063的规定。
1)硫酸根标准溶液:应符合GBW (E) 080267的规定。
J)锉离子标准溶液:应符合GBW (E) 070309的规定。
k)钠离子标准溶液:应符合GBW (E) 080243的规定。
l)按离子标准溶液:应符合GBW (E) 080421的规定。
m)钾离子标准溶液:应符合GBW (E) 080125的规定。
n)镁离子标准溶液:应符合GBW (E) 080126的规定。
0)钙离子标准溶液:应符合GBW (E) 080118的规定。
P)银离子标准溶液:应符合GBW (E) 080242的规定。
9)钡离子标准溶液:应符合GBW (E) 080243的规定。
4.2.28 指示剂。
a)铬酸钾指示剂:PK,CIO,=50g/L (p为溶液的质量浓度)
b)甲基橙指示剂:"am =1g/L,
c)酚酞指示剂:pow =1g/L,其介质为体积分数是90%的乙醇溶液。
d)甲基红指示剂:P甲魏 = 1g几,其介质为体积分数是60%的乙醇溶液。
e)铬黑T指示剂:PiSXT = 5g/L,其介质为体积分数是50%的三乙醇按溶液。
f)钙试剂指示剂:称取0.5g钙试剂和5g硫酸钾于玛瑙乳钵中,研磨至0.18mm,保存在干燥器
中。
9)淀粉指示剂:PV*二5g/L,现配。
4.3 材料
4.3.1容量瓶:lOmL, 25mL, 250mL, 500rnL, A级。
4.3.2 大肚移液管:1mL, 5mL, lOmL, 25mL, 50mL, A级。
4.3.3 三角瓶:250mLo
SY/T 5523-2000
4.3.4 烧杯:250mLo
4.3.5 碘量瓶:250mL.
4.3.6 玻璃漏斗:价90mmo
4.3.7 棕色酸式滴定管:50mL, A级。
4.3.8 蓝背线酸式滴定管:50mL, A级。
4.3., 蓝背线碱式滴定管:25mL, A级。
4.3.10 慢速定量滤纸:声110mmo
4.3.11 pH试纸:pH值为1一14.
4.3.12 瓷增竭:10ML.
5 仪器和设备
5.1离子色谱仪。
5.2韦氏天平。
5.3分析天平:感量0.0001g,感量0. 1g.
5.4 pH计:定量重复性为0.02pHo
5.5 电炉:1000w.
5.6 高温炉:1000℃士10'C o
5.7 电热板:looowa
5.8 密度仪:精确至0.00001g/cMI,
5.9 烘箱:2400W.
6 物理性质的测定
6.1 颜色
目测水样颜色,其可分为:无色、浅黄色、黄色、绿色、棕色和黑色等。
6.2 气味
启开瓶塞嗅气味,其可分为:无气味、硫化氢味、泥土味、沼气味、芳香味和刺激味等。
6.3 透明度
目测水样透明度,其可分为:透明、半透明和不透明等。
6.4 沉淀物
观察水样中沉淀物的数量及形状,数量可分为:无、少量和大量;形状可分为:片状、粒状和絮
状等。
6.5酸度 (pH计电测法)
6.5.1仪器校准
用pH值为4.0, 7.0, 10.0主种标准缓冲溶液校准pH计:先将pH计调到pH值为7.0处,视
pH计在各缓冲溶液中的读数,误差不得大于0.02pH单位,否则应重新校准pH计。
6.5.2 测定
将校准后的pH计的电极浸入盛有50mL水样的烧杯中,待仪器稳定后读数。
6.6 密度
6.6.1韦氏天平法
6.6.1.1 天平校准
将测锤浸人去离子水中,不得接触容器的底和壁。挂最大砖码于钩上,调节平衡锤,使横梁上指
针与托架指针成水平,记下去离子水温度。
6.6.1.2 测宁
sy 理 弱23-2侧犯
将测锤浸没水样中 (浑浊水样需经过滤),不得接触容器的底和壁。由大而小添加祛码到v形槽
中,至梁的指针尖与托架针尖成水平,记下水样温度t(℃)及祛码质量。祛码质量数值即为该水样
的实测密度 (If,)的数值。
6.6.1.3 水样密度不大于1.01oog/cm3时的计算公式
温度在5--35℃时的精确计算见式 (1):
D20=D,` D 4`一;(20一:) ................................. (1)
温度在15-25℃时的近似计算见式 (2):
D20二0.99823侧 ................................. (2)
式中:D驴— 水样的标准密度,g/cm3;
侧— 水样在t度时的实测密度,g/crn3 ;
D'4— 纯水在t度时的密度,g/cm3;
t— 水样温度,℃;
r 温度系数,见表1;
0.99823— 纯水在20℃时的密度,9/cin30
表1 温度系数
温度范围
℃
温度系数 r
x 10-0
一 温度范围
}{ ℃
温度系数 r
x 10-0
5.0-10.0 1.10 >20.0-25.0 2.30
> 10.0- 15.0 1.50 }一 2.50
>15.0-20.0 1.80 1 2.75?6.6.1.4水样密度大于1.010鲍/ml时的计算公式 〔见式 (3)]
Da=D,一r(20一t)
式中:D驴— 水样的标准密度,g/crn3 ;
众— 水样在t度时的实测密度,9/m3;
r 温度系数,见附录B(标准的附录);
t-— 水样温度,℃。
6.6.2 电磁振荡密度仪法
6·6.2.1仪器校准
根据仪器的操作说明,用纯水对仪器进行校准,重复性偏差不得超过0.00001g/cm3a
6.6.2.2 测定
仪器校准后将试样注人仪器,稳定后对试样进行读数测定。
7 抓离子含f的测定
7.1硝酸银沉淀滴定法
该法适用于油气田水中氯离子含量在100mg/L以上,澳、碘离子合量为氯离子含量的1%以下
时氯离子含量的测定。
7.1.1 方法提要
一 5 一
SY/f 5523-2000
在pH值为6.0-8.5的介质中,硝酸银离子与氯离子反应生成白色沉淀。过量的银离子与铬酸
钾指示剂生成砖红色铬酸银沉淀,根据硝酸银离子的消耗量计算氯离子含量。其反应方程式如下:
掩十+Cl 八彭〕寺(白色)
2Ag' + CA写一~AgzCrO4今(砖红色)
7.1.2 试样制备
无色、透明、含盐度高的油气田水样,经适当稀释 (稀释后的试样,氯离子的含量应控制在501〕一
3000mg几)即可测定。如水样中含有硫化氢,则在水样中加数滴硝酸溶液怀刚鸟二50%)煮沸除去硫
化氢,如水样浑浊,则用滤纸过滤,去掉机械杂质,记作滤液A,保留滤液A用于氯离子的测定。
7.1.3 测定
用大肚移液管取定体积油气田水样或经处理后的试样或滤液A(试料中氯离子含量应为10-
40mg)于三角瓶中,加水至总体积为50一60mL,用硝酸溶液(CPHN03 = 50%)或碳酸钠溶液
(WN.}CO,=0.05%),调节试样pH值至6.0--8.5,加1ML铬酸钾指试剂。用硝酸银标准溶液滴至生
成淡砖红色悬浮物为终点。用同样的方法做空白实验。
7.1.4 计算
氯离子含量的计算见式 (4)、式 (5): ??cig (V,二VOM)、103
Pa (Mg几)=cim(Vl*一VoM) X 35.45X 103
?
???
?
mmol几 )=
式中:cm- 硝酸银标准溶液的浓度,mol/L;
Vrm- 硝酸银标准溶液的消耗量,ML;
Volp— 空白试验时,硝酸银标准溶液的消耗量,ML;
V— 试料的体积 (原水水样),ML;
35.45一 与1.OOML硝酸银标准溶液(cam; =1.000mol/L)完全反应所需要的氯离子的质
量,mg.
7.1.5质量要求
氯离子平行样品分析结果应符合表2的质量要求。
表2 抓离子平行样品分析结果的质量要求
氛离子含量范围
mg几
J
相对偏差
%
抓离子含盘范围
Mg 几
相对偏差
%
100-1000 3.0 } > la洲洲)~5佣00 is
>1000-5000 } >5阅加 一100000 1.0
>5000一10000 }} >100000-200000 0.8
7.2 离子色谱法
该法适用于油气田水中氟、氯、澳、硫酸根离子的测定,它们的最低
质量浓度均为0.05mg/Lo
7.2.1 方法提要
试样注人后,在淋洗液的携带下流经阴离子分离柱。由于四种离子的离子半径、电荷的多少和其
他性质的不同,它们对固定相的亲合力各异,因此在淋洗液和固定相之间的分配系数也不同。在柱中
经反复洗脱与交换后,按氟、氯、澳、硫酸根离子的顺序依次被分离开来,经电导检测器测量,由计
一 6 一
SY/1' 5523- 2000
算机计算并打印出被测离子的含量。
7.2.2 试样制备
水样用滤纸过滤除去机械杂质,取其滤液,经适当稀释即可。
7.2.3 色谱条件
7.2.3.1 淋洗液:Na2C03"NaHCO3二元淋洗液浓度分别为2.Ommol/L和3.Ommol/Lo
7.2.3.2 淋洗液流速:选用试样中被测离子峰达到完全分离的流速。
7.2.3.3 色谱柱:与仪器配套的阴离子分离柱。
7.2.4 分析程序
7.2.4.1标准溶液的制备。在各离子的线性范围内,制备与试样中氟、氯、澳和硫酸根离子含量近
似的混合标准液。
7.2.4.2 测定。按色谱条件将仪器准备好,待基线稳定后,输人样品名称及稀释倍数,注人试样,
屏幕上出现色谱图,计算机测定各离子峰的电信号强度 (mv"s);在同样的色谱条件下,输人标准溶
液中各离子名称及含量,注人标准溶液,计算机将测得各离子电信号强度 (mv"s)与试样中相应离
子电信号强度比较,计算并打印出样品中各离子含量。
7.2.5 质量要求
氟、氯、澳、硫酸根离子平行样品分析结果应符合表3的质量要求。
表3 氟、抓、澳、硫酸根离子平行样品分析结果的质量要求
项 目 含量范围
mg几
相对偏差
%
氟离子
5-10 10.0
>10--50 8.0
>50-200 5.0
抓离子
10-100 10.0
>100-1000 8.0
> 1000-20000 5.0
>20000-100000 3.0
>100000-200000 1.5
澳离子
10-100 10.0
>100-500 8.0
>500-1000 5.0
>1000-5000 3.0
硫酸根离子
10-1加 10.0
>100-1000 6.0
>1000 -3000 4.0
>3000--5000 2.0
8 碳酸根、碳酸级根、氮氛根离子含t的测定
该法适用于一般油气田水中碳酸根、碳酸氢根、氢氧根离子含量的测定及水中共存的硼酸盐、硅
酸盐、亚硫酸盐和磷酸盐等碱性物质干扰测定。
一 7 一
SY厅 5523- 2000
8.1 方法提要
用盐酸标准溶液滴定水样,依次用酚酞和甲基橙溶液为指示剂,用两次滴定所消耗盐酸标准溶液
的体积,计算碳酸根、碳酸氢根和氢氧根离子的含量,反应方程式如下:
OH一+H
CO;-+H'
酚酞指示剂
酚酞指示剂
H2O
HCO3
HC03 + H`里到些鱼甄呱个十玫。
8.2分析程序
用大肚移液管取50 --100ML刚开瓶塞的水样于三角瓶中,加2--3滴酚酞指示剂。若水样出现红
色,则用盐酸标准溶液滴至红色刚消失,所消耗的盐酸标准溶液的体积 (ML),记作Vlg。再加3一
4滴甲基橙指示剂,水样呈黄色,则继续用盐酸标准溶液滴至溶液由黄色突变为橙红色,所消耗的盐
酸标准溶液的体积 (xnL),记作V2,C。若加酚酞指示剂后水样呈无色,则继续加甲基橙指示剂至水
样呈黄色,用盐酸标准溶液滴定至橙红色为终点。
8.3 计算
碳酸根、碳酸氢根和氢氧根离子的含量关系见表40
表4 碳酸根、碳酸氢根和氢氧根离子的含量关系
盐酸耗量 碳酸氢根 碳酸根 氢氧根
V,k=O V7盐 0 0
V,g< V21k V21k一Vlg V,盐 0
Vilk二V2& 0 V,盐 0
Via >V2m 0 V29 V,g一V24
VZ盆=0 0 0 V,盐
当V,k =0时,表明仅有碳酸氢根离子,其含量计算见式 (6)、式 (7):
CH,,3 (mmol/L) = C"V211 x 103 (6)
PHOO3(nig几)二CA V2盐x 61.02 V 又103 ..................... (7)
当VIA < V29时,表明有碳酸氢根和碳酸根离子,无氢氧根离子。碳酸根和碳酸氢根离子含量
的计算见式 (8)一式 (11): ??HCO, (mmol几)=c盐(V盐一V1盐)x 103???
????
????
?
????
PHCO; (mg几
c以
x1护
nmmol/L)=CA VIA V x1护
POO;- (rng/L)二c盐VIA x 60.01 V X 103
当V1盐=矶盐时,表明仅有碳酸根离子,用式 (10)、式 (11)计算其含量。
当VIA > V2tt时,表明有碳酸根和氢氧根离子,无碳酸氢根离子,其含量计算见式 (12)
(15)
cc&-(mmol/L) = CA V2u x 103
SYPI' 5523-2000
叫一(mg几卜cX V2tk x, 60.01P&3-(Mg/L) = V x 103
oEf (mmol/L) = C&(Vik - V21)V 、103
................... (13)??P.,f (mg/L) = c&(V,&杀&) x 17.01 x 103
当V2*二0时,表明仅有氢氧根离子,其含量计算见式 (16)、式 (17) ??二(mmol/L)=CV ALx103一 v
POH(mg/L)=
:cstk 盐酸标准溶液的浓度,mol/L;
c盐Vljk x 17.01
V x 103
Vt,k— 加酚酞指试剂时,盐酸标准溶液的耗量,ML;
V2ac— 加甲基橙指示剂时,盐酸标准溶液的耗量,mL;
V— 试料的体积 (原水水样),ML;
61.02, 60.01, 17.01— 分别表示与1.OOML盐酸标准溶液 (CHa = 1.000mo1/L)完全反应
所需要的碳酸氢根、碳酸根和氢氧根离子的质量,mg.
质量要求
碳酸氢根、碳酸根离子平行样品分析结果应符合表5的质量要求
表5 碳酸氢根、碳酸根离子平行样品分析结果的质量要求
??
?
?
??
项 目
含量范围
刀艰几
相对偏差
%
碳酸氢根离子
50-200 12.0
>200--600 3.0
>600一1200 2.0
碳酸根离子 30-50 7.5
, 硫酸根离子含t的测定
9.1 重量法
该法适用于油气田水中含量为40--5000mg/L硫酸根离子的测定。
9.1.1 方法提要
在酸性溶液中,硫酸根离子与钡离子反应生成硫酸钡沉淀。经过滤、洗涤、碳化、灼烧至恒量,
按公式计算硫酸根离子含量。当试料中铁离子含量大于lmg时,测定前需用氨水除去。其反应方程
式如下:
洲一+Ba21二BaSO4 }
时++30H-一 Fe(OH)3告
9.1.2 试样制备
用大肚移液管取定体积水样 (硫酸根离子含量应为5-150mg)于烧杯中,加2--3滴甲基红指示
剂,加盐酸溶液帅HQ二50%)酸化样品;置烧杯于电炉上煮沸5min,搅拌下滴加氨水神NH,- Hzo=
50%)使溶液呈碱性。铁离子以氢氧化物形式沉淀,待沉淀完全后,趁热过滤;将杯中沉淀全部移至
滤纸上,用热水洗涤至滤液无氯离子;滤液和洗涤液一并收集在另一烧杯中,用水冲稀至120-
一 9 一
SY汀 5523-2000
150mL,记作滤液B。保留滤液B用于硫酸根离子含量的测定。
9.1.3 测定
使用除去铁离子得到的滤液B测硫酸根离子含量。向滤液B滴加盐酸溶液(Pra=50%)使呈酸
性,置烧杯于电炉上,煮沸;搅拌下滴加IOML氯化钡溶液,煮沸3一5min,在约60℃处静置4h.
在定量滤纸上过滤,将烧杯中沉淀全部移至滤纸上,用热水洗涤沉淀至滤液无氯离子;将滤纸和沉淀
放人已恒量的增祸中,先在电炉上碳化至滤纸变白;最后将增祸放人高温炉中,升温至800r-,恒温
30min;停止加热,待炉温降到400℃时取出增坍,并在干燥器中冷却至室温,称量、再灼烧至恒量,
两次称量相差不超过0. 0004g.
9.1.4 计算
硫酸根离子含量的计算见式 (18)、式 (19),
Pso;-(mg几 (m2一ml) x 411.57 Vu
洲 一(mg几)
x1护
c戏长mmol几)= x 0.01041
......·一(18)
................... (19)
式中:mi 增坍质量,g;
m2 柑涡加沉淀质量,g;
V— 试料的体积 (原水水样),ML;
411.57— 生成1.0000g硫酸钡所需要的硫酸根离子的质量,mg;
0.01041— 生成1.Omg硫酸根所需要的硫酸根离子的质量,mmolo
9.1.5 质量要求
硫酸根离子平行样品分析结果应符合表6的质量要求。
表6硫酸根离子平行样品分析结果的质量要求
I * JR范围 }甲 相对伯差 II 含量范围
功9几
RO-200
>200--1000 7.05.0
Mg 几
>1000-2000
>2000-5000
相对偏差
%
2.0
1.5
9.2 离子色谱法
离子色谱法见7.20
10 镁、钙、OR、钡离子含f的侧定
10.1络合滴定法
该法适用于油气田水中镁、钙、钡 (钡、银合量)离子含量的测定。
10.1.1方法提要
镁、钙、银、钡离子在pH值为10的缓冲溶液中,以铬黑T为指示剂,用EDTA标准溶液滴定
测得总量。在州 值为3-4的介质中,用硫酸钠作沉淀剂,除去水样中钡、银离子。除去钡、铭离
子的试样,分别在pH值为10的缓冲溶液中以铬黑T为指示剂,用EDTA标准溶液滴定,测得镁、
钙离子合量;在州值为12的介质中以钙试剂为指示剂,用EDTA标准溶液滴定,测得钙离子含量。
铁离子有干扰,当试料中铁离子含量大于lmg时,需除去铁离子。其反应式如下:
y4-*Ne, pHtrL兰lo My2-
y4-+(}2+丝边三Cay2-
1332' (STI' )+洲- pH1lt3-4S04 卜 BaSW SLSO4 )寺
SY汀 5523-2仪犯
Me 十+20H-一 Mg(OH)2告
Fe3+ pH值为9一 下
煮沸 Fe(OH)3十
10.1.2 分析程序
10.1.2.1除铁离子
用大肚移液管取定体积水样 (钙含量应在100mg)于烧杯中,加水使总体积为80mL,加0.3g氯
化按,用盐酸溶液 师Ha= 1%)调节溶液咐值至3-4;在电炉上煮沸,搅拌下滴加5一IOML浓氨
水,煮沸lmin;趁热过滤,用热水洗沉淀至无氯离子,滤液和洗涤液一并收集在另一烧杯中,置烧
杯于电炉上,煮沸、逐尽氨;冷却至室温后,用盐酸溶液(PHCI二1%)调节滤液pH值至3--4,移
人250mL容量瓶中,定容、摇匀;记作滤液C,保留滤液C用于镁、钙、银、钡离子总量的测定。
10.1.2.2 镁、钙、银、钡离子总量的测定
使用除去铁离子得到的滤液C测镁、钙、银、钡离子的总量。用大肚移液管取定体积滤液C于
三角瓶中,加水使总体积为SOmL,加IOML氨水一抓化按缓冲溶液,加3-4滴铬黑T指示剂。用
EDTA标准溶液滴至纯蓝色为终点。EDTA标准溶液耗量 (ML)记作姚。
10.1.2.3 镁、钙离子合量的测定
用大肚移液管取定体积滤液C(钙含量应在40mg左右)于烧杯中,加水稀释至120mL,置烧杯
于电炉上,加热至微沸;搅拌下滴加 IOML硫酸钠溶液,煮沸3一5min,在60℃下静置4h。将溶液
和沉淀一并移人250mL容量瓶中,定容、摇匀。放置数分钟后,在滤纸上干过滤;记作滤液D,保
留滤液D用于镁、钙离子的测定。使用除去钡、银离子得到的滤液D测镁、钙离子合量。用大肚移
液管取定体积滤液 D(与测镁、钙、iff、钡四种离子总量的原水样体积相同)于三角瓶中,按
10.1.2.2进行测定,EDTA标准溶液耗量 (mL)记作玖。
10.1.2.4 钙离子的测定
使用除去钡、银离子得到的滤液D测钙离子含量。用大肚移液管取与测镁、钙离子合量的体积
相同的滤液D于三角瓶中,加水至总体积为80mL,加IOML氢氧化钠溶液 【wNeOH = 4 ,再加
3mg钙指示剂。用EDTA标准溶液滴至纯蓝色为终点,EDTA标准溶液耗量 (mL) D记作V5-
10.1.3计算
镁、钙、钡 (钡、铭合量)离子含量的计算见式 (20)一式 (25):
_,+‘__。。、_CO V5、,n3 .....................⋯⋯,,。
L哎飞 、1瓜从 1娜JL, 二“I ee 丫了 尹、 工U 、‘ U 尹
一 v
Pca2' (mg/L)=co砚 x 40.08 V
_ctF(Va一V5)
x1沪 (21)
C时+ (mmol/L) x 103
Peas' (mg几)= x 103
CBz'(B2'+ S2') (mmol/L)_c%(V3 - V4) x 103
v
PB}' (mg几 cc,(姚一Va) x 137.34 V x 103
?
?
?
式中:cV,- EDTA标准溶液的浓度,mol/L;
姚— 测镁、钙、银、钡离子合量时,EDTA标准溶液的消耗量,ML;
Va 测镁、钙合量时,EDTA标准溶液的消耗量,mL;
砚— 测钙离子时,EDTA标准溶液的消耗量,mL;
V— 试料的体积 (原水样体积),mL;
SY/*I' 5523-2000
40.08, 24.31, 137.34一 分别为与1.OOmL EDTA标准溶液 (cwrp= 1.0000mo1/L)完全反
应所需要的钙、镁、钡离子的质量,mg.
10.1.4 质量要求
镁、钙、铭、钡离子平行分析结果应符合表7的质量要求。
表7 镁、钙、铭、钡离子平行分析结果的质量要求
项 目
含量范围
n犯2
相对偏差
%
钙离子
10-100 10.0
>100-500 8.0
>500-1000 5.0
>1000-5000 3.0
>5000-20000 1.5
镁离子
5-20 15.0
>20-100 10.0
>100-300 8.0
>300-500 6.0
>500-2000 3.0
钡离子+银离子
300-1000 10.0
>1000-2000 8.0
>2000-5000 3.0
10.2离子色谱法
该法适用于油气田水中的碱金属和碱土金属离子即:铿、钠、按、钾、镁、钙、铭和钡离子测
定。它们的最低检测质量浓度均为0.05mg/L.
10.2.1方法提要
该条见7.2.1.
10.2.2锉、钠、按、钾、镁、钙、惚、钡离子含量的测定
10.2.2.1 色谱条件
淋洗液:甲烷磺酸,CCH3803H为15-35mmo1/L;
流速:各离子达到完全分离;
色谱柱:与仪器配套的阳离子分离柱。
10.2.2.2分析程序
标准溶液的制备:在各离子的线性范围内,制备1个与试样中锉、钠、按、钾、镁、钙、铭、钡
离子含量相近的混合标准溶液。
其测定见7.2.4.2.
10.2.2.3质量要求
锉、钠、馁、钾、镁、钙、银、钡离子平行样品分析结果应符合表8的质量要求。
10.3 钡离子的测定 (铬酸盐容量法)
该法适用于油气田水中钡离子含量大于100mg/L的测定。
SY/T 5523- 2000
表8 铿、钠、按、钾、镁、钙、银、钡离子平行样品分析结果的质量要求
项 目
含量范围内
mg几
相对偏, }
% }
铿离子
10-50 10.0
>50-100 7.0
> 100 -300 5.0
>300一1000 3.0
钠离子
10- 100 10.0
> 100- 1000 8.0
>1000-5000 6.0
>5000-30000 3.0
> 3000(】一100000 2.0
铁离子
10-50 10.0
>50-300 6.0
>300- 1000 4.0
钾离子
10-100 10.0
>100-1000 6.0
> 1000- 5000 3.0
>5000-30000 2.0
镁离子
5-20 10.0
>20-100 8.0
> 100- 300 6.0
>300--2000 3.0
钙离子
10-50 10.0
>50-200 8.0
>200-500 6.0
>500-5000 5.0
>5000-20000 2.0
铭离子
20-100 10.0
> 100-500 8.0
>500-2000 6.0
>2000-5000 3.0
钡离子
80-200 10.0
>200-1000 8.0
> 1000-" 3000 4.0
13
SYPr 5523- 2000
10.3.1方法提要
在州值为5.7--6.1的介质中,钡离子与铬酸钾反应生成铬酸钡的沉淀。共存的镁、钙、银则
仍以离子形态留在液相中,经过滤、洗涤、弃去滤液而得到铬酸钡的沉淀。沉淀物用盐酸重新溶解,
生成的铬酸钡与固体碘化钾反应,释放出单质碘,用硫代硫酸钠标准溶液测定碘。计算钡离子含量
(水样中铁、铝离子干扰测定,需预除去)。其反应式如下:
Bat十+CrO4'-一 BaCrO4寺
2BaCrO4+6KI+16HCI一 312+6KC1+2CiC13+2BaC12+8践O
12+2Na2易几一 2Nal+Nat民氏
10.3.2分析程序
10.3.2.1除铁、铝离子
用大肚移液管取定体积经过滤后水样于烧杯中,加2-3mL浓硝酸,煮沸数分钟,冷却;用氢氧
化钠溶液(.NaOH= 20 %)中和至溶液混浊,MA硝酸溶液(tuHNo3=50%)至沉淀恰溶;用水稀释至
100mL,加10--15mL乙酸钠溶液(W a< COON8二12%)煮沸使沉淀凝聚,冷却后移入250mL容量瓶
中,定容、摇匀;记作溶液E,保留滤液E用于钡离子的测定。
10.3.2.2 测定
用大肚移液管取定体积溶液E澄清液 (钡离子含量应为10 - 50mg)于烧杯中,加水稀释至
150mL,加2滴甲基红指示剂;用盐酸溶液 (pHa=50%)和氨水调节溶液至黄色,加lOmL乙酸一
乙酸按缓冲溶液,煮沸;搅拌下滴加20mL铬酸钾溶液,再煮沸,补加20mL铬酸钾溶液;在电热板
上静置1.5h,取下静置12h后在定量滤纸上过滤,用乙酸铰溶液洗涤烧杯和沉淀物各三次;洗尽,
弃去滤液和洗涤液;将滤纸戳破,滴加盐酸溶液神,u=50%)溶解沉淀于原烧杯中,再用热水洗滤
纸至无氯离子;用水洗烧杯壁并稀释至100ML,再用氨水(PNH,.HZO = 50 %)和盐酸溶液帅Ha =
50%)调至沉淀物完全溶解;加20mL铬酸钾溶液,加热至沸,慢慢加人lOmL乙酸一乙酸铰缓冲溶
液,于电热板上加热保持1.5h,取下,冷却,沉淀在滤纸上过滤;用乙酸按溶液洗涤沉淀至滤液无
色,滴加盐酸溶液 (PHa=50%)于滤纸上溶解沉淀,并收集在碘量瓶中,用热水洗涤滤纸至无氯离
子;加2g碘化钾,摇匀,置于暗处,半分钟后用硫代硫酸钠标准溶液滴至浅黄色;加1ML淀粉指示
剂,继续滴至蓝色消失,绿色出现为终点。同样方法做空白试验。
10.3.3 计算
钡离子含量的计算见式 (26):
Ba?' (mg几
_cart(讥一叭)x 45.77
一 v x 103 .....................(26)
式中:‘硫代— 硫代硫酸钠标准溶液的浓度,mol几;
V6 硫代硫酸钠标准溶液的消耗毋,n止;
V7— 空白试验时,硫代硫酸钠标准溶液的消耗量,ML;
V— 试料的体积 (原水样体积),ML;
45.77一 与1.OOmL硫代硫酸钠标准溶液(恤X03 =1.000mol旧 完全反应所需要的钡离子
质量,Mg .
10.3.4 质量要求
铬酸盐容量法测钡离子平行样品分析结果应符合表9的质量要求。
10.4 原子吸收法测定
该法见SY/1' 59820
SY汀 5523- 2000
表9 钡离子平行样品分析结果的质量要求
钡离子含量范围
mg几
相对偏差
%
100- 500 8.0
>500-1000 4.0
>1000-3000 2.0
n 碘、澳离子含t的测定
11.1碘量法
该法适用于碘离子含量大于5mg/L,澳离子含量大于20mg/L油气田水的测定。
11.1.1方法提要
在州值为3.0--4.0时,碘化物被澳水氧化成碘酸盐。过量的澳用甲酸钠和苯酚分解。碘酸盐
与加人的碘化钾反应,释放出碘,用硫代硫酸钠标准溶液滴定。
用差减法测定澳。在姆值为5.5--7.0的介质中,澳离子、碘离子均被次氯酸钠盐氧化成稳定
的澳酸盐和碘酸盐。过量的次氯酸盐用甲酸钠分解、除去。澳酸盐和碘酸盐与加人的碘化钾反应,生
成的碘用硫代硫酸钠标准溶液滴定 (共存的硫化氢、铁离子、锰离子和有机物等,应预先除去)。其
反应式如下:
I- + 3Br2 + 3玫0- 1街 十6H' +6Br-
Br2 + HCOO-- 2Br- + H* + C01
I03 +51一+6H+- 312+3H20
b十2Na2S20 - >2Na卜 Na2Sa06
Br" (I-) + 3C10-- Br03 OW ) + 3C1-
CIO- + 2H000---C1- + COz,+残O
BrCS (I03)+ 6KI+ 6HCI- 312 + Br- + 6KC1+ 3H20
12+2Na2S103- 2NaI+Na2S406
11.1.2 制样
11.1.2.1碘离子的定性
取5mL水样于试管中,加数滴盐酸溶液 (pHc,=50%),再加少许抓酸钾,最后加数毫升三氯甲
烷,振荡;若三氯甲烷层中显粉红色,则表明水样中含碘离子。
11.1.2.2 澳离子的定性
取5ML水样于试管中,加数滴重铬酸钾溶液、1ML浓硫酸、1mL硫酸品红溶液和2mL三氯甲
烷;激烈振荡,在三氯甲烷层中出现红色,则表明水样中含澳离子。
11.1.2.3 样品预处理
用大肚移液管取定体积含碘、澳离子的水样于烧杯中,加两滴硝酸溶液( 9HNO3一50%),放置1
-2h后加氢氧化钠溶液 (.NeOH = 4 %)至铁离子完全沉淀;加5一IOML碳酸锌悬浮液,在电炉上加
热至微沸,冷却后移人250mL容量瓶中,定容、摇匀、干过滤;记作滤液F,保留滤液F用于碘、
澳离子的测定。
一 15 一
SY汀 5523-2000
11.1.3 分析程序
11.1.3.1 碘离子的测定
使用除去硫化氢、铁离子、锰离子和有机物得到的滤液F测碘离子的含量和碘、澳离子合量。
用大肚移液管取定体积滤液F(碘离子含量应为1-2mg)于碘量瓶中,加1--2滴甲基橙指示剂;加
冰乙酸使溶液呈酸性,再