S10A THRU S10M
SURFACE MOUNT GENERAL RECTIFIER
Reverse Voltage - 50 to 1000 Volts Forward Current - 10.0 Amperes
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
S10A
VOLTS
VOLTS
VOLTS
SYMBOLS UNITS
Amps
Amps
Volts
VRRM
VRMS
VDC
I(AV)
IFSM
VF
10.0
200.0
1.2
Operating junction and storage temperature range
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current
at TL=75 C
Peak forward surge current
8.3ms single half sine-wave superimposed on
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 10.0A
Maximum DC reverse current TA=25 C
at rated DC blocking voltage TA=100 C
Typical junction capacitance (NOTE 1)
IR
10.0
100.0
RθJA
CJ
TJ,TSTG
10.0
60.0
-55 to +150
pF
C
Aµ
Typical thermal resistance (NOTE 2) C/W
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
S10B S10D S10G S10J S10K S10M
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
Dimensions in inches and (millimeters)
Case: JEDEC DO-214AB molded plastic body
Terminals: Solder plated, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight:0.007 ounce, 0.25grams
The plastic package carries Underwriters Laboratory
Flammability Classification 94V-0
For surface mounted applications
Low reverse leakage
Built-in strain relief,ideal for automated placement
High forward surge current capability
High temperature soldering guaranteed:
250 C/10 seconds at terminals
FEATURES
MECHANICAL DATA
0.280(7.11)
0.260(6.60)
0.245(6.22)
0.220(5.59)
DO-214AB/SMC
0.126 (3.20)
0.114 (2.90)
0.060(1.52)
0.030(0.76)
0.320(8.13)
0.305(7.75)
0.012(0.305)
0.006(0.152)
0.008(0.203)MAX.
0.103(2.62)
0.079(2.06)
MDD Catalog Number
MDD ELECTRONIC
*Pulse test: Pulse width 200 �sec, Duty cycle 2%
Note: 1. High Temperature Solder Exemptions Applied, see EU Directive Annex 7.
MDD ELECTRONIC
Average Forward Rectified Current - Amperes versus
Case Temperature - �C
Figure 2
Forward Derating Curve
40 60 100 120 140 160
0
2
4
6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
�C
80
8
10
12
Figure 3
Junction Capacitance
.1 .2 1.4 2 10 20 404 100 200
10
20
60
100
200
1000
Junction Capacitance - pF versus
Reverse Voltage - Volts
pF
Volts
600
400
40
400 1000
TJ=25�C
Figure 1
Typical Forward Characteristics
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Volts
4
6
20
10
Amps
.5 1.5.7 .9 1.1 1.3
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25�C
40
60
100
1.7
RATINGS AND CHARACTERISTIC CURVES S10A THRU S10M
MDD ELECTRONIC
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
1 1004
0
50
100
150
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2 6 10 20 60 8040
200
250
300
Figure 4
Typical Reverse Characteristics
Volts
40
60
200
100
�Amps
20 12040 60 80 100
.1
.2
.4
.6
1
2
4
6
10
20
TA=25�C
400
600
1000
140
RATINGS AND CHARACTERISTIC CURVES S10A THRU S10M