1ER5018
ER
50
18
For the Latest Information
On the Internet: www.omron-industrial.com or www.sti.com
Compact Rope Pull Emergency Stop Switch
ER5018
• Compact size allows this switch to be used on
smaller machines with a mounting width of 40 mm
and covering rope spans up to 40 m
• Tension indicator—the tension indicator makes the
system easy to set up and to maintain the proper
rope tension
• Contact arrangements of 2 N/C + 1 N/O or 3 N/C
• IP67 (NEMA 6) enclosure enables the ER5018
switch to withstand water washdown cleaning
• Heavy-duty housing—the die-cast housing and
stainless steel eye nut makes the ER5018 suitable
for demanding industrial applications
• Integral E-Stop—the optional E-stop provides emer-
gency stopping at the extreme end of the installation
• Reset button—the blue reset button must be
pushed in order to return to “machine run” condition
following switch actuation by a pulled or slacked
rope
• Long life—the ER5018 switch is designed for a min-
imum of one million actuations
• Vibration tolerant—the snap-acting switch contacts
protect against nuisance tripping due to vibration
Operation
Blue Reset Button
A blue reset button is provided to easily return
the unit back to its machine-run position after
actuation.
Emergency Push Button
The emergency push button may
be installed or repositioned in the
field. The ER5018 has two possi-
ble mounting positions for the
emergency stop button.
Installation Hardware Available
RK Rope Tension Kit
The RK Rope Tension Kit comes
with all of the required hardware
for most installations. A spring is
required as shown in the installa-
tion example below.
Installation Hardware
Individual hard-
ware items may
be purchased for
specific installa-
tion requirements.
Tension/Gripper
Spring
Turnbuckle
Eyebolt
Thimble
Double Loop Clip
Rope Pulley
E53E-EN-01+ER5018+Datasheet.fm Seite 1 Freitag, 12. Oktober 2007 12:35 12
2 Compact Rope Pull Emergency Stop Switch
For the Latest Information
On the Internet: www.omron-industrial.com or www.sti.com
Contact Arrangements
Mounting Specification
Note: Some installations may require a ER5018 on each end.
Applications
Typical applications are on conveyor systems and
across rotating machinery, and around hazardous
areas.
Ordering information
Compact Rope Pull Emergency Stop Switch
Accessories
E-Stop Contacts Wiring Entry Model
Not included 2 N/C + 1 N/O 3 x M20 ER5018-021M
Not included 3 N/C 3 x M20 ER5018-030M
Included 2 N/C + 1 N/O 3 x M20 ER5018-021ME
Included 3 N/C 3 x M20 ER5018-030ME
Item Model
Replacement Lid SM06-SL400
Rope Kit, 5 m, Stainless Steel RK5
Rope Kit, 10 m, Stainless Steel RK10
Rope Kit, 20 m, Stainless Steel RK20
Rope Kit, 50 m, Stainless Steel RK50
Rope Only, 5 m R5M
Rope Only, 10 m R10M
Rope Only, 20 m R20M
Rope Only, 50 m R50M
Rope Only, 100 m R100M
Rope Only, 126 m R126M
Tensioner Gripper, Stainless Steel SM06-TG00
Eye Bolt Stainless Steel, 8 per pack SM06-EB10
Double Loop Clip, Stainless Steel, 4 per pack SM06-DL20
Thimble Stainless Steel, 4 per pack SM06-THSS
0 mm
11/12
21/22
33/34
2NC + 1NO Versions Rope Slack Tension Range Rope Pulled
Contact Open Contact Closed
11/12
21/22
31/32
3NC Versions Rope Slack Tension Range Rope Pulled
14.5 mm 17.0 mm3.5 mm
ER5018
≤ 40 m
≤ 500 mm ≤ 500 mmEvery ≤ 3 m Every ≤ 3 m
Eyebolt Support Safety Spring WallTensioner Gripper
E53E-EN-01+ER5018+Datasheet.fm Seite 2 Freitag, 12. Oktober 2007 12:35 12
3ER5018
ER
50
18
For the Latest Information
On the Internet: www.omron-industrial.com or www.sti.com
Specifications
Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e., with the rope properly tensioned and the
machine able to be started.
Dimensions
Turnbuckle, Stainless Steel SM06-TB30
Spring, Stainless Steel SM06-SP50
Rope Pulley, Stainless Steel SM06-RPSS
E-Stop Mechanism SM06-ES60
Electrical
Contact Configurations 2 N/C + 1 N/O, 3 N/C
Safety Contacts 2 N/C, 3 N/C
Switching Ability AC: 120 V–6 A, 240 V–3 A, InductiveDC: 24 V–2.5 A, Inductive
Auxiliary Contacts 1 N/O
Max Switching Current/Volt/Amp 240 V/720 VA
Minimum Current 5 V, 5 mA DC
Electrical Life 1,000,000 minimum
Mechanical
Mounting Any position
Mounting Hardware 2 x M5 screws
Actuator Travel for Positive Opening See diagrams on previous page
Max Rope Span 40 m
Operation Force < 125 N
Tensioning Force to Run Position 130 N typical
Case Material Die-cast aluminum alloy
Eye Nut Material Stainless steel
Wiring Entry 3 x M20
Weight 675 g
Color Yellow
Mechanical Life 1,000,000 minimum
Environmental
Protection IP67 (NEMA 6)
Operating Temperature -25 to 80°C
Cleaning Water washdown
Compliance
Standards IEC947-5-1, IEC947-5-5, EN418, UL508, BS5304
Approvals/Listings CE marked for all applicable directives, UL and C-UL
Item Model
74
57
23
90139
40
46
25
25
10
57
188 205MIN - MAX
2 mtg holes clearance
for M5 screws
E53E-EN-01+ER5018+Datasheet.fm Seite 3 Freitag, 12. Oktober 2007 12:35 12
4 Compact Rope Pull Emergency Stop Switch
For the Latest Information
On the Internet: www.omron-industrial.com or www.sti.com
Safety precautions
Operating instructions
Installation must be in accordance with the following steps and stated
specifications and should be carried out by suitably competent personnel.
Adherence to the recommended maintenance instructions forms part of
the warranty.
! WARNING Do not defeat, tamper, remove or bypass this unit.
Severe injury to personnel could result.
W
! WARNING
1. Installation of all Safety Rope Switch systems must be in accordance
with a risk assessment for the individual application. Installation must
only be carried out by competent personnel and in accordance with
these instructions.
2.Rope support eyebolts must be fitted at 2.5 m. min. to 3 m. max. inter-
vals along all rope lengths between switches. The rope must be
supported no more than 500 mm from the switch eyebolt or Safety
Spring (if used). It is important that this first 500 mm is not used as part
of the active protection coverage.
3.M5 mounting bolts must be used to fix the switches. Tightening torque
for mounting bolts to ensure reliable fixing is 4 Nm. Tightening torque for
the lid screws, conduit entry plugs and cable glands must be 1.5 Nm to
ensure IP seal. Only use correct sizing glands for conduit entry and
cable outside diameter.
4.Tensioning of rope is achieved by use of tensioner / gripper assemblies.
Upon installation, tension to mid-position as indicated by the red arrows
in the viewing window of each switch. Check operation for all switches
and the control circuits by puling the rope at various locations along the
active protection area and resetting each switch by depressing the Blue
Reset button. Ensure each time that the switches latch off and require
manual resetting by depressing the Blue Reset button. Increase the sys-
tem tension further, if required, depending upon the checks along the
active length of coverage. If fitted with a Mushroom type E-Stop button
(Red) then test and reset each switch to ensure function of control cir-
cuits. Typical operational conditions for successful operation of system
is less than 75 N. pulling force and less than 150 mm deflection of rope
between eyebolt supports. If the optional LED is fitted but is not used,
ensure that the conductors remain coiled and tied to the tie hole in the
LED flange.
5.Every week: Check correct operation of system at locations along all
coverage length. Check for nominal tension setting, re-tension rope if
necessary. Every 6 months: Isolate power and remove cover. Check
screw terminal tightness and check for signs of moisture ingress. Never
attempt to repair any switch.
(120VAC)
(120VAC)
Green
Red
(common )
Black
Red
Green
Black(+24VDC)
(+24VDC)
Optional 24 VDC Indicator Beacon
When +24VDC is applied to the red wire, the beacon will illuminate red
and flash.
When +24 VDC is applied to the green wire, the beacon will illuminate
green.
Optional 120 VAC Indicator Beacon
When +120VAC is applied to the red wire, the beacon will illuminate red
and flash.
When +120 VAC is applied to the green wire, the beacon will illuminate
green.
(0 V)
Tension Indicator
Indicator shown with steel rope properly adjusted.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E53E-EN-01
E53E-EN-01+ER5018+Datasheet.fm Seite 4 Freitag, 12. Oktober 2007 12:35 12