可充电型真空吸尘器正常温升测试规范真空吸尘器正常温升测试(可充电型) 真空吸尘器正常温升测试(可充电型) 修订 日期 修订 单号 修订内容摘要 页次 版次 修订 审核 批准 2011/03/30 / 系统文件新制定 2 A/0 / / / 更多免费资料下载请进:http://bbs.bz01.com 好好学习社区 批准: 审核: 编制: 真空吸尘器正常温升测试(可充电型) 1.0 Purpose / 目的 To determine the temperatures that exist within the rechargeable type sample w...
可充电型真空吸尘器正常温升测试规范
真空吸尘器正常温升测试(可充电型) 真空吸尘器正常温升测试(可充电型) 修订 日期 修订 单号 修订内容摘要 页次 版次 修订 审核 批准 2011/03/30 / 系统文件新制定 2 A/0 / / / 更多免费资料下载请进:http://bbs.bz01.com 好好学习社区 批准: 审核: 编制: 真空吸尘器正常温升测试(可充电型) 1.0 Purpose / 目的 To determine the temperatures that exist within the rechargeable type sample when operated under all conditions of normal use and evaluate if temperatures rise comply with the values specified in Table 9, UL1017. 评估可充电型樣機在正常使用中其温升是否符合UL10179所规定的值. 2.0 Definition/概念: 2.1 Discharge-Operate the sample no longer to operate with the switch in the” on” position for an additional hour 电池完全放电-运行样機直到其完全停止,再保持开关处在开的位置上多一个小时. 2.2 Recharge-Charge the discharged sample for 16 hours through the charger connected to supply mains of 120V/60Hz 充电-让电池完全放电的样機通过充电器接上120V/60Hz电源充电16小时. 3.0 Reference Documents/參考文獻: ULS-01017-DMLW-DataSheet-2001 Form Issued: 1992-07-01 Form Revised: 2006-07-07 4.0 Equipment/設備: 4.1 Data logger & plug-type module. 安捷伦Datalogger和通道插機 4.2 J-type thermocouple wire. J型溫度線 4.3 Sicomet99 & Parsec Activator. 4.4 UL test carpet UL地毯 4.5 2 pcs Digital multimeter 两块万用表 4.6 Frequency converter變頻电源 5.0 General Instructions/說明: 5.1 Tests may be conducted at any ambient temperature within a range of 10-40℃ (50-100℉). 測試可在10~40℃(50~100℉)之內的環境溫度下進行. 5.2 Unless otherwise noted, all tests are to be conducted with appliance connected to a 120VAC, 60Hz power source. 除非另外標注, 否則所有样機都将连接在120V/60Hz電源下进行測試. 5.3 All equipment used must be calibrated on an annual basis. Calibration stickers with last calibration and calibration due date must be affixed to each instrument. 使用的所有設備都必須以一年為周期進行調校. 載有最後調校日期和調校周期的調校粘紙必須被粘固在每一個儀表上. 5.4 For this test, the sample must be operated from chamber temperature. 所有测试中样機都从室温状态起动 6.0 Procedure/步驟: 6.1 Obtain two representative samples of the appliance to be tested. 準備一台有代表性的樣機用來測試. 6.2 Obtain Test Results Form TTR1032 and completely fill in the information describing the sample and the equipment used prior to running the test. 用TTR1032結果的表格, 在測試運作前完整地填入樣機和使用的設備的情況. 6.3 Discharge and recharge the samples. 對樣機放電後再充電. 6.4 Measure the mean wattage Wmean according to the method described in TAREGW 1031. 按照TAREGW 1031测出平均功率W平均后,保持其进气开口不变。。 6.5 Discharge one sample and affix the thermocouple wire to it. 將其中一台樣機進行完全放電, 並粘上J型溫度線. 6.6 Recharge temperatures: Record the temperatures when recharging the sample for 16 hours. 让样機开始充电,温度16小时。 6.7 Mean wattage temperatures or open inlet temperatures: Disconnect the sample from the charger and operate it continuously with the air intake partially blocked to initially cause the mean wattage Wmean, then record the temperatures until the sample ceases operation, the inlet restriction is not adjusted during test; However, if the sample is of dust collector type and doesn’t employ a flow-thru type motor, the sample is only tested with the air inlet completely open. 重新充满电后,将样機在平均功率的开口下运行,记录温度直到其停止,但是如果样機属积尘式且采用非流通式马达(flow-thru type)时,不用做平均功率运行而是测试其在进气口全开状况下的温度。 6.8 If the sample has other functions, it is to be tested additionally as below after being recharged: 如果样機还有以下功能,还要分别按以下测试: a)​ It has a motorized nozzle or a motor driven brush (or similar device) and is tested operating on carpet;or 如果样機带地拖,将其重新充满电后,测试其在地毯上运行时的温度。 b)​ It can be operated as a blower and is tested with the air inlet and air outlet completely open. 如果样機带鼓风功能,将其重新充满电后,测试其在进气口和排气口全开状况下的温度。 6.9 After the test, temperatures rise shall not exceed the Table 9 in UL1017. 温升不得超过UL1017表9所规定的值.。 7.0 Results/結果: 7.1 Use the corresponding Test Results Form TTR1032 to report all numerical results as the information described below. 使用TTR1032測試結果的表格, 除報告所有數字結果外, 還有下列描述的資料. 7.2 Clearly and completely describe all parts that are part of this evaluation. Include all model numbers, manufacturing date codes, materials, plastic part revision letters, and modification status. 清楚并完整地描述本評估的所有零件, 包括所有型號名稱, 材料和塑膠零件改版符號. 7.3 Clearly and completely describe all special conditions of the test (i.e. Was the test performed in exact accordance with the test procedure or were there special variations). 清楚并完整地描述所有測試的特殊條件(即按照測試程序實際進行的測試或特殊的變改)。
/
本文档为【可充电型真空吸尘器正常温升测试规范】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索