ENGINEERING DATA SHEET
SERIES 328
CONTACTOR
1PDT-DB-DM+AUX, 300 AMP/28 VDC
Permanent duty
Main contact 1NO + 1NC
Auxiliary contact 2NO + 2NC
Coil supply Direct current
- Polarized and protected coil See schematic diagram
Meets the requirements of AIR 7304 AIR 8456B
AIR 9456 MIL 6106J
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at 300 A / 28 Vdc
Weight
- Ref. P/N: 328 870 g ±10%
- Ref. P/N: S328 920 g ±10%
- Ref. P/N: M328 945 g ±10%
Maximum size 130mm x 70mm x 62.5mm
Dust proof metal can.
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating per pole and load type
Load Current in Amps
@28Vdc
Resistive
Inductive
Motor
Overload
Rupture
I minimum
300 (In)
180
300
8 In [1]
10 In [2]
In/10
Auxilary contact rating @28Vdc @115Vac/400Hz
Resistive
Inductive (L/R=5ms)
Lamp
5
2.5
2
5
2.5
2
Notes:
[1] 2400 Amps for 50 cycles; duty cycle: .2 sec on, 20 sec off.
[2] 3000 Amps for 50 cycles; duty cycle: .2 sec on, 20 sec off.
3. Other models available upon request. Contact factory.
[4] Additional temperature ratings available.
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 6/06 - 185 - Page 1 of 3
COIL CHARACTERISTICS AT 20 °C SERIES 328
Nominal operating voltage 28 Vdc
Maximum operating voltage 32 Vdc
Maximum pickup voltage 18 Vdc
Drop-out voltage 2 Vdc min. to 8 Vdc max.
Cut-in current 10 A at 28 Vdc
Holding current 300 mA at 28 Vdc
GENERAL CHARACTERISTICS
Temperature range -55°C to +85°C [4]
Minimum operating cycles (life) at rated load 50,000 cycles
Dielectric strength at sea level 500 Vrms
Dielectric strength at altitude 25,000 m 300 Vrms
Insulation resistance at 500 Vdc 100 M Ω
Sinusoidal vibration 10 G / 5 to 2000 Hz
Shock 30 G / 11 ms
Maximum contact opening time under vibration and shock 10 µs
Maximum operate time at 28 Vdc 30 ms
Maximum release time at 28 Vdc 20 ms
Main contact voltage drop
- Initial value 120 mV
- After endurance test 180 mV
Auxiliary contact voltage drop
- Initial value 60 mV
- After endurance test 120 mV
Auxiliary contacts
- Contact resistance (low level) 1 Ω
- I minimum 2 mA
Assembly torque
- Main contact terminals 8.3 Nm
Date of issue: 6/06 - 186 - Page 2 of 3
MOUNTING STYLES SERIES 328
TERMINAL TYPES
SCHEMATIC DIAGRAM
NUMBERING SYSTEM
S 328
1 - Mounting Style (S,M)_________________________| |
2 - Basic series designation____________________________|
Date of issue: 6/00
- 187 -
Page 3 of 3
328
328
328M
S
TYPE M328
TYPES 328/S328
STANDARD TOLERANCE : ±0.5
DIMENSIONS IN MM
4 MOUNTING HOLES
60
3
4.5 DIA
23
3.6
40 23
PANEL CUTOUT
A D
60
70
23
BC
DA 55 DIA
35
60
70
23
BC 55 DIA
35
= WITHOUT BASE AND CLAMP
= WITH BASE AND CLAMP
10/45
50
40
130±1
50
32
40
= WITH MOULDED BODY
130±1
4 STUDS
M8
7
4 STUDS
16
7
M8
16
4 M8 STUDS
9
A D
C B
(HE 301 B 1H 12 10 P)
MS 3113 H 12 10 P
RECEPTACLE
STANDARD TOLERANCE : ±0.5
DIMENSIONS IN MM
MAIN CONTACTS COIL TERMINALS / AUXILIARY CONTACTS
16 DIA LUG SEAT TYP
20 MAX LUG DIA
12 EACH REQUIRED
- FLAT WASHER
- HEX. NUT
- LOCKWASHER
BD
AC -K +J C A
D BFH
EG