E
1
8.
05
5.
5/
03
.1
1
71
Electronic
Pressure Switch
EDS 1700
Description:
The EDS 1700, with its integrated
pressure measuring cell, 4-digit display
and 4 switching outputs, offers the
user all the advantages of a modern
electronic pressure switch.
4 switching points and switch-back
points can be adjusted very simply and
independently of each other using the
keypad.
For optimum incorporation into
monitoring systems (e.g. with PLC), an
analogue output (4 .. 20 mA or 0 .. 10 V)
is also available.
The main applications of the EDS 1700
are in hydraulics and pneumatics.
The instrument is ideal for use where
frequent switching cycles (several
million) require permanent switching
point accuracy or simple and precise
adjustment.
Special features:
Integrated pressure sensor
with strain gauge on
stainless steel membrane
Accuracy 0.5 % or 1 % FS
4-digit display
Simple operation via key
programming
4 limit relays, switching points and
switch back points can be adjusted
independently
Analogue output signal selectable
Many useful additional functions
Optional mounting position
(pressure connection on the top/
bottom, keypad and display can be
turned through 180°)
Can be set to display values in
any unit of measurement e.g.: kN, kg,
psi, ...
Technical specifications:
Input data
Measuring ranges 16; 40; 100; 250; 400; 600 bar
Overload pressures 32; 80; 200; 500; 800; 1000 bar
Burst pressures 200; 200; 500; 1000; 2000; 2000 bar
Mechanical connection Threaded port G1/4 DIN 3852
Torque value 20 Nm
Parts in contact with medium Mech. connection: Stainless steel
Output data
Accuracy to DIN 16086, EDS 1700-P: ≤ ± 0.5 % FS max.
Max. setting EDS 1700-N: ≤ ± 1 % FS max.
(display, analogue output)
Repeatability EDS 1700-P: ≤ ± 0.25 % FS max.
EDS 1700-N: ≤ ± 0.5 % FS max.
Temperature drift EDS 1700-P ≤ ± 0.02 % FS / °C max. zero point & range
Temperature drift EDS 1700-N ≤ ± 0.03 % FS / °C max. zero point & range
Analogue output
Signal selectable 4 .. 20 mA ohmic resistance ≤ 400 W
0 .. 10 V ohmic resistance ≥ 2 kW
Switching outputs
Type 4 relays with change-over contacts
(2 groups, common supply of each group con.)
Switching voltage 0.1 .. 250 V AC / DC
Switching current 0.009 .. 2 A per switching output
Switching output max. 50 W / 400 VA
(for inductive load, use varistors)
Switching cycles 20 million at minimum load
1 million at maximum load
Reaction time approx. 20 ms
Ambient conditions
Compensated temperature range -10 .. +70 °C
Operating temperature range -25 .. +60 °C
Storage temperature range -40 .. +80 C
Fluid temperature range -25 .. +80 °C
mark EN 61000-6-1 / 2 / 3 / 4
Vibration resistance to ≤ 5 g
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance to ≤ 10 g
DIN EN 60068-2-29 (1 ms)
Protection class to DIN 40050 IP 65
Other data
Supply voltage 22 .. 32 V DC
Current consumption approx. 200 mA
Residual ripple of supply voltage ≤ 10 %
Display 4-digit, LED, 7 segment, red,
height of digits 13 mm
Electrical connection 14-pole, terminal block
Housing material aluminium, anodised
Weight approx. 800 g
Note: Reverse polarity protection of the supply voltage, excess voltage, override
and short circuit protection are provided.
FS (Full Scale) = relative to complete measuring range
E
1
8.
05
5.
5/
03
.1
1
72
E
1
8.
05
5.
5/
03
.1
1
73
Model code:
EDS 1 7 9 X – X – XXX – 000
Mechanical connection
9 = threaded port G1/4 DIN 3852
Display
1 = 4-digit bar
2 = 4-digit psi
Accuracy
P = 0.5 %
N = 1 %
Pressure ranges in bar
016; 040; 100; 250; 400; 600
Modification number
000 = standard
Note:
Special models on request.
On units with a different modification number, please read the label or the technical
amendment details supplied with the unit.
Accessories:
Appropriate accessories, such as mechanical adapters etc. can be found in the
Accessories section.
Setting options:
The core of the unit is a microprocessor
which provides many useful extra functions
in addition to normal pressure switch
operation. It is possible, for example, to
activate switching delay times to prevent
fast pressure peaks from triggering an
unwanted switching cycle. All settings are
made using the keypad.
Setting ranges of the
switching points:
Switching point relay 1 to 4:
1.5 % .. 100 % FS
Switch-back relay 1 to 4:
1 % .. 99 % FS
or alternatively
switch-back hysteresis 1 to 4:
1 % .. 99 % FS
Note: FS (Full Scale) =
relative to the full measuring range
Setting options:
Switching direction of the relays 1 to 4
(N/C or N/O)
Switch-on delay relays 1 to 4 in the
range 0.00 .. 90 seconds
Switch-back delay relays 1 to 4 in the
range 0.00 .. 90 seconds
Switch-back mode (either switch-back
point or switch-back hysteresis)
Display of the actual pressure, a
switching point or of the peak value
Display filter (slow / medium / fast)
Display range scale individually
adaptable (bar, psi, user-selectable)
Measurement unit (bar, psi) is displayed
Analogue output (4 .. 20 mA or 0 .. 10 V)
Programming disable
Terminal assignment:
Note:
The information in this brochure relates to
the operating conditions and applications
described.
For applications and operating conditions
not described, please contact the relevant
technical department.
Subject to technical modifications.
ElEcTrONIc GMbH
Hauptstraße 27, D-66128 Saarbrücken
Tel. +49 (0)6897 509-01
Fax +49 (0)6897 509-1726
E-Mail: electronic@hydac.com
Internet: www.hydac.com
Dimensions:
Pin
1 +UB
2 0 V
3 Analogue output signal +
4 Analogue output signal - (0 V)
5 Relay 1 N/C
6 Relay 1 N/O
7 Centre relay 1 and 2
8 Relay 2 N/C
9 Relay 2 N/O
10 Relay 3 N/C
11 Relay 3 N/O
12 Centre relay 3 and 4
13 Relay 4 N/C
14 Relay 4 N/O
cable gland PG 11
G1/4 DIN3852 female
countersink to DIN 74-KM5