电气电缆代号
Code and installation mode of pipe line
I. code of pipe line
SC: welded steel pipe, TC: wire tube, PC: rigid plastic tube, CT: cable tray, CP: metal hose, SR steel wire groove RC: water gas pipe
Two, wire laying parts:
SR: laying along the cable, CLE: laying along columns or columns, WE: laying along the wall, CE: laying along the ceiling or ceiling
ACE: the access ceiling shall be laid and the BC: shall be laid in the beam. CLC: concealed in the post, and WC: concealed in the wall
FC: pre buried in the ground, CC: buried in the roof
00DX001 standard for graphic and text symbols in architectural electrical engineering design published by the China Institute of architectural standards and design:
Line laying mode marking:
Welded steel pipe laying: SC
Conduit laying: MT
Rigid plastic pipe laying: PC
Flame retardant semi rigid PVC pipe laying: FPC
Cable tray laying: CT
Metal line laying: MR
Laying of plastic groove: PR
Laying with cables: M
PVC insulated corrugated pipe laying: KPC
Laying through metal hose: CP
Direct Embedment: DB
Cable trench laying: TC
Concrete pipe laying: CE
Marking of laying points of wires
Lay along or cross beam (roof truss): AB
Dark deposited in the beam: BC
Laying along or across columns: AC
Buried in columns: CLC
Laying along wall: WS
Lay in the wall: WC
Laying along ceiling or top panel: CE
Buried in roof or roof: CC
Ceiling laying: SCE
Floor or ground laying: F
JDG-- compact wire tube, wire pressing type KBG-- tube
First, the conductor through the tube that
MT- wire tube
PC-PVC plastic hard tube
FPC- flame retardant plastic hard tube
CT- Bridge
MR- metal wire groove
M- cable
CP- metal hose
PR- plastic wire groove
RC- galvanized steel pipe
Two. Indication of wire laying method
DB- buried directly
TC- cable trench
BC- concealed in the beam
CLC- concealed in columns
WC- concealed in the wall
CE- is laid along the ceiling
CC- concealed in the ceiling
SCE- ceiling laying
F- floor and floor
SR- along the tightrope
BE- along the roof beam
WE- lay open along the wall
The B series is classified as a fabric cord and therefore begins
with B,
V is PVC pvc,
L is the code for the aluminum core
R is the meaning of (soft), to be soft is to increase the number of conductors
BV copper conductor PVC insulated wire
BLV aluminium core PVC insulated wire
BVR copper conductor PVC insulated flexible wire
ZR flame retardant
WDZ halogen free, low smoke and flame retardant;
People ask Ping, commonly used wires on the market, BV, BVR, RV, RVV, not those large section of the project cable
The B series are classified as cloth wires, so start with B, voltage: 300/500V
V is PVC PVC, that is (plastic)
L is the code for the aluminum core
"R" means "soft". To be soft is to increase the number of conductors
BV copper conductor PVC insulated wire
BLV aluminium core PVC insulated wire
BVR copper conductor PVC insulated flexible wire
Above wire structure: conductor + insulation
Take 2.5mm2 for example:
BV is 1 in diameter, 1.78mm in 7, and 0.68 in two
BLV is the 1 diameter 1.78mm
BVR is the 19 diameter 0.41mm
RV copper core PVC insulated flexible wire
Is it softer than BVR, or 2.5 is the 49 0.25mm copper wire?
RVV copper core PVC insulated PVC sheathed flexible wire
More than RV a layer of plastic sheath
In addition: our most commonly used "sheath line""
BVVB copper conductor PVC insulated and sheathed flat cable
It's 2 BV lines, plus a white sheath on the top
Give you valuable information
I collected electrical design, construction drawings are commonly used line laying method:
SR: laying along the steel groove
BE: laying along the roof truss or roof truss
CLE: laying along columns or columns
WE: laying along the wall
CE: laying along the ceiling or ceiling
ACE: laying in the access ceiling
BC: buried in the beam
CLC: buried in the column
Ws: buried in the wall
CC: concealed in the ceiling
ACC: concealed in the ceiling that is not accessible
FC: buried in the ground
SCE: the ceiling should be laid with metal pipe
First, the conductor through the tube that
SC- welded steel pipe
MT- wire tube
PC-PVC plastic hard tube
FPC- flame retardant plastic hard tube
CT- Bridge
MR- metal wire groove
M- cable
CP- metal hose
PR- plastic wire groove
RC- galvanized steel pipe
Two. Indication of wire laying method
DB- buried directly
TC- cable trench
BC- concealed in the beam
CLC- concealed in columns
WC- concealed in the wall
CE- is laid along the ceiling
CC- concealed in the ceiling
SCE- ceiling laying
F- floor and floor
SR- along the tightrope
BE- along the roof beam
Ws- lay open along the wall
Three, the installation of lamps means
CS- chain sling
DS- pipe hanger
W- wall mounting
C- suction top
R- embedding
S- stent
CL- column
Along the steel groove: SR
Along the roof truss or cross roof: BE
Along columns or columns: CLE
Welded steel pipe laying: SC
Conduit laying: MT
Rigid plastic pipe laying: PC
Flame retardant semi rigid PVC pipe laying: FPC
Cable tray laying: CT
Metal line laying: MR
Laying of plastic groove: PR
Laying with cables: M
PVC insulated corrugated pipe laying: KPC
Laying through metal hose: CP
Direct Embedment: DB
Cable trench laying: TC
Marking of laying points of wires
Lay along or cross beam (roof truss): AB
Dark deposited in the beam: BC
Laying along or across columns: AC
Buried in columns: CLC
Laying along wall: WS
Lay in the wall: WC
Laying along ceiling or top panel: CE
Buried in roof or roof: CC
Ceiling laying: SCE
Floor or ground laying: FC
Serial number
Marking of wire laying method
New code
(English)
Chinese name
Old code name
(Pinyin)
One
K
With porcelain or ceramic column laying
CP
Two
PR
Lay down with a plastic slot
XC
Three
SR (MR)
Lay in a wire trough
GC
Four
RC (GG)
Water gas (Galvanized) pipe laying
XG
Five
SC (G)
Welded steel pipe laying
G
Six
TC, MT
Lay the wire through the pipe
DG
Seven
PC
PVC rigid pipe laying
VG
Eight
FPC
PVC semi rigid pipe laying
RVG
Nine
KPC
PVC plastic corrugated pipe laying
Ten
CT
Laying by cable bridge
Eleven
PL
Be laid with a porcelain clip
CJ
Twelve
PCL
Fit in a plastic clip
VJ
Thirteen
CP
Lay down with metal hose
SPG
Fourteen
AL
Aluminum card distribution
QD
Fifteen
M
Wire distribution
S
Sixteen
Slot plate wiring
CB
Serial number
Marking of laying points of wires
New code
(English)
Chinese name
Old code name
(Pinyin)
One
E
Ming Fu
M
Two
C
Dark enough
A
Three
SR, M
Lay along the cable
S
Four
BE
Lay along the roof truss or span roof truss
LM
Five
CLE, AC
Lay along columns or columns
ZM
Six
R
Framework
Seven
WE, WS
Lay along the wall
QM
Eight
CE
Lay along the ceiling or ceiling
PM
Nine
ACE
It can be laid in the suspended ceiling
PNM
Ten
BC
Concealed beam
LA
Eleven
CLC
Lay concealed in the column
ZA
Twelve
WC
Lay in the wall
QA
Thirteen
FC
Buried in the ground
DA
Fourteen
CC
Buried in the roof
PA
Fifteen
ACC
Buried in the ceiling can not be entered
PNA
Serial number
Labeling of electric light source type
New standard
Type of electric light source
Old standard
One
IN
Incandescent lamp
B
Two
FL
Fluorescent lamp
Y
Three
I
Iodine tungsten lamp
L
Four
Hg
Mercury lamp
G
Five
Na
Sodium lamp
N
Six
Xe
Xenon lamp
Seven
Ne
Neon lamp
Eight
ARC
Arc lamp
Nine
IR
Infrared lamp
Ten
UV
Ultraviolet lamp
Serial number
Marking of installation methods of lamps and lanterns
New code
(English)
Chinese name
Old code name
(Pinyin)
One
CP
Wire hanging type and self feeder hanging type
X
Two
CP1
Fixed wire suspension type
X1
Three
CP2
Waterproof hanging type
X2
Four
CP3
Suspension type
X3
Five
Ch
Chain lifting
L
Six
P, DS
Pipe hanging type
G
Seven
W
Wall mounted
B
Eight
S, C
Suction top or straight attached type
D
Nine
R, FB
Embedded system
R
Ten
CR
Ceiling mounted (suction, recessed, recessed)
DR
Eleven
WR
Installed inside wall (wall mounted)
BR
Twelve
T
Installation on platform
T
Thirteen
SP
Mounting on bracket
J
Fourteen
CL
Post installation
Z
Fifteen
HM
Seat.
ZH
Code for lamps and lanterns
Luminaire type
Code name (Pinyin)
Luminaire type
Code name (Pinyin)
Ordinary Chandelier
P
Cast light
T
Wall lamp
B
Factory lights
Flameproof lamp
G
Festive lantern
H
Ceiling lamp
D
Fluorescent lamp
Y
Column lamp
Z
Waterproof and Dustproof lamp
F
Halogen tungsten searchlight
L
Enamel umbrella lamp
S