AEROSPACE STANDARD
(R) WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/
POLYIMIDE INSULATED, NORMAL WEIGHT, SILVER
COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER, ALLOY, 200 °C, 600 VOLTS
A
S2
27
59
/8
9
Copyright 2007 SAE International
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying,
recording, or otherwise, without the prior written permission of SAE.
TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)
Fax: 724-776-0790 Email: CustomerService@sae.org SAE WEB ADDRESS: http://www.sae.org
IS
SU
ED
2
00
0-
06
R
EA
FF
IR
M
ED
2
00
6-
04
R
EV
IS
ED
2
00
7-
08
THIRD ANGLE PROJECTION
CUSTODIAN: SAE AE-8/AE-8D
R
EV
.
B
FEDERAL SUPPLY CLASS
6145
AS22759/89
SHEET 1 OF 6
REV.
B
SA
E
Te
ch
ni
ca
l S
ta
n
da
rd
s
Bo
ar
d
Ru
le
s
pr
ov
id
e
th
at
:
“T
hi
s
re
po
rt
is
p
ub
lis
he
d
by
S
AE
to
a
dv
an
ce
th
e
st
at
e
o
f t
ec
hn
ic
al
a
nd
e
n
gi
ne
e
rin
g
sc
ie
nc
es
. T
he
u
se
o
f t
hi
s
re
po
rt
is
e
n
tir
el
y
vo
lu
nt
ar
y,
a
nd
its
a
pp
lic
ab
ilit
y
a
n
d
su
ita
bi
lity
fo
r a
n
y
pa
rti
cu
la
r u
se
,
in
cl
ud
in
g
a
n
y
pa
te
nt
in
fri
ng
em
e
n
t a
ris
in
g
th
er
ef
ro
m
,
is
th
e
so
le
re
sp
o
n
si
bi
lity
o
f t
he
u
se
r.
”
SA
E
re
vie
ws
e
a
ch
te
ch
ni
ca
l r
ep
or
t a
t l
ea
st
e
ve
ry
fi
ve
y
ea
rs
a
t w
hi
ch
ti
m
e
it
m
ay
b
e
re
a
ffi
rm
ed
,
re
vis
e
d,
o
r c
a
n
ce
lle
d.
SA
E
in
vit
es
y
ou
r w
rit
te
n
c
o
m
m
e
n
ts
a
n
d
su
gg
es
tio
ns
.
RATIONALE
TOTAL REVISION AND UPDATE WORD-FOR-WORD MIL SPECIFICATION CONVERTED TO SAE STANDARD.
NOTICE
THE REQUIREMENTS FOR ACQUIRING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS
SPECIFICATION SHEET AND THE ISSUE OF THE FOLLOWING SPECIFICATION LISTED IN THAT ISSUE OF THE
DEPARTMENT OF DEFENSE INDEX OF SPECIFICATIONS AND STANDARDS (DODISS) SPECIFIED IN THE
SOLICITATION: AS22759.
THIS SPECIFICATION IS NOT INTENDED FOR USE IN NAVAL AIRCRAFT OR NAVAL AIR SYSTEMS APPLICATIONS.
1/ ALLOY CONDUCTOR: THE SIZE 26 CONDUCTOR SHALL BE ULTRA-HIGH STRENGTH COPPER ALLOY. THE
BREAKING STRENGTH SHALL BE 21.5 LB (MINIMUM) AND THE CONDUCTOR ELONGATION 6.0% (MINIMUM). ALL
OTHER GAUGE SIZES SHALL BE HIGH STRENGTH COPPER ALLOY IN ACCORDANCED WITH AS22759.
FIGURE 1 - GENERAL CONFIGURATION
CONDUCTOR, STRANDED, SILVER COATED,
HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER ALLOY 1/
FP TAPE
FP / POLYIMIDE / FP TAPE
FP – FLUOROCARBON POLYMER, MODIFIED
POLYTETRAFLUOROETHYLENE (PTFE)
Copyright SAE International
Provided by IHS under license with SAE
Not for ResaleNo reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---
AEROSPACE STANDARD
(R) WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/
POLYIMIDE INSULATED, NORMAL WEIGHT, SILVER
COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER, ALLOY, 200 °C, 600 VOLTS
A
S2
27
59
/8
9
R
EV
.
B
AS22759/89
SHEET 2 OF 6
REV.
B
TABLE 1 - CONSTRUCTION DETAILS
CONDUCTOR FINISHED WIRE
DIAMETER
(IN)
DIAMETER
(IN)
WEIGHT
(LB/1000
FT) 2/
PART NO. 1/
WIRE
SIZE
STRANDING
(NUMBER OF
STRANDS
X AWG
GAUGE OF
STRANDS) MIN MAX
RESISTANCE
AT 20 °C
(68 °F)
(OHMS/1000
FT MAX) MIN MAX MIN TARGET MAX
M22759/89-26-*
M22759/89-24-*
M22759/89-22-*
M22759/89-20-*
26
24
22
20
19 X 38
19 X 36
19 X 34
19 X 32
0.0175
0.0225
0.0285
0.0365
0.0204
0.0244
0.0314
0.0395
56.4
28.4
17.5
10.7
0.033
0.038
0.043
0.051
0.037
0.042
0.047
0.055
1.34
1.87
2.70
4.25
1.47
2.04
2.90
4.45
1.60
2.20
3.10
4.65
1/ PART NUMBER: THE ASTERISKS IN THE PART NUMBER COLUMN OF TABLE 1 SHALL BE REPLACED BY COLOR
CODE DESIGNATORS IN ACCORDANCE WITH MIL-STD-681. EXAMPLES: M22759/89-20-93 IS A 20 AWG WHITE
WITH ORANGE STRIPE.
2/THE ACCEPTABLE VALUE FOR THE CPK FOR THE FINISHED WIRE WEIGHT LISTED SHALL BE 1.3, USING A
NORMAL (GAUSSIAN) DISTRIBUTION TO OBTAIN THOSE CPK VALUES.
TABLE 2 - WIRE INSULATION MATERIALS 1/
TAPE CODE THICKNESS (NOM) MATERIAL
1 0.0020 0.0005 (FP)/0.0010 (POLYIMIDE)/0.0005 (FP)
2 0.0020 FP (UNSINTERED)
1/ PHYSICAL PROPERTIES OF FP TAPES SHALL BE IN ACCORDANCE WITH AS22759 REQUIREMENTS.
TABLE 3 - PHYSICAL PROPERTIES OF FP/POLYIMIDE/FP TAPES
TENSILE STRENGTH 19,000 LB/IN SQ (AVERAGE MINIMUM)
TENSILE MODULUS 350,000 LB/IN SQ (AVERAGE MINIMUM)
ELONGATION 40 PERCENT (AVERAGE MINIMUM)
DIELECTRIC STRENGTH 4,000 VOLTS/MIL (AVERAGE MINIMUM)
0.0005 FP LAYER (BOTTOM) DISTINGUISHABLE COLOR (NEXT TO CONDUCTOR)
MAY BE USED AT MANUFACTURER'S OPTION
TABLE 4 - TAPE OVERLAP REQUIREMENTS 1/
WRAP 1 WRAP 2
PERCENT
OVERLAP
PERCENT
OVERLAP WIRE
SIZE
TAPE
CODE MIN MAX
TAPE
CODE MIN MAX
NOMINAL
WALL
THICKNESS
(MILS)
26 1 50.5 54.0 2 50.5 54.0 7.4
24 1 50.5 54.0 2 50.5 54.0 7.4
22 1 50.5 54.0 2 50.5 54.0 7.4
20 1 50.5 54.0 2 50.5 54.0 7.4
1/ WRAP 1 IS INNERMOST TAPE WHICH IS IN CONTACT WITH THE CONDUCTOR.
Copyright SAE International
Provided by IHS under license with SAE
Not for ResaleNo reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---
AEROSPACE STANDARD
(R) WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/
POLYIMIDE INSULATED, NORMAL WEIGHT, SILVER
COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER, ALLOY, 200 °C, 600 VOLTS
A
S2
27
59
/8
9
R
EV
.
B
AS22759/89
SHEET 3 OF 6
REV.
B
RATINGS:
TEMPERATURE RATING: 200 °C (392 °F) MAXIMUM CONTINUOUS CONDUCTOR TEMPERATURE.
VOLTAGE RATING: 600 VOLTS (RMS) AT SEA LEVEL.
ADDITIONAL REQUIREMENTS:
WET ARC PROPAGATION RESISTANCE (TEST REQUIRED FOR INITIAL QUALIFICATION ONLY): TEST IN
ACCORDANCE WITH AS4373, METHOD 509. MEASURE THE DAMAGE OF THE BUNDLE ALONG THE AXIS. THE
WIRE IS ACCEPTABLE IF THE FOLLOWING CRITERIA ARE MET:
1. A MINIMUM OF 67 WIRES PASS THE DIELECTRIC TEST.
2. THREE WIRES OR LESS FAIL THE DIELECTRIC TEST IN ANY ONE BUNDLE.
3. ACTUAL DAMAGE TO THE WIRE IS NOT MORE THAN 3 INCHES IN ANY TEST BUNDLE.
DRY ARC PROPAGATION RESISTANCE (TEST REQUIRED FOR INITIAL QUALIFICATION ONLY): TEST IN
ACCORDANCE WITH AS4373, METHOD 508. MEASURE THE DAMAGE OF THE BUNDLE ALONG THE AXIS. THE
WIRE IS ACCEPTABLE IF THE FOLLOWING CRITERIA ARE MET:
1. A MINIMUM OF 67 WIRES PASS THE DIELECTRIC TEST.
2. THREE WIRES OR LESS FAIL THE DIELECTRIC TEST IN ANY ONE BUNDLE.
3. ACTUAL DAMAGE TO THE WIRE IS NOT MORE THAN 3 INCHES IN ANY TEST BUNDLE.
BLOCKING: 200 °C ± 2 °C (392 °F ± 3.6 °F)
COLOR: WHITE IS THE PREFERRED COLOR AND SHALL BE IN ACCORDANCE WITH MIL-STD-104, CLASS 2.
COLORS SHALL BE LASER MARKABLE AND MEET THE COLOR LIMITS BELOW. CONFORMITY OF COLOR SHALL
NOT BE REQUIRED AFTER OVEN EXPOSURE.
MUNSELL COLOR LIMITS FOR UV LASER MARKABLE WIRE
HUE VALUE CHROMA COLOR FROM TO FROM TO FROM TO
BLACK
BLUE
GREEN
RED
YELLOW
BROWN
ORANGE
VIOLET
2.5N
5PB
2.5G
10RP
5Y
2.5YR
10R
2.5P
2.5N
7.5B
7.5G
5R
10Y
7.5R
2.5YR
7.5R
7
7
7
7
8
7
6
7
8.5
8
9
8
9
9
7
8
N/A
4
2
4
4
2
8
4
N/A
6
6
6
6
4
10
8
GRAY SAME AS BLACK SAME AS BLACK SAME AS BLACK
COLOR STRIPING OR BANDING DURABILITY: 125 CYCLES (250 STROKES), 250 GRAMS WEIGHT
CONDUCTOR STRAND ADHESION: REQUIRED
CONTINUOUS LENGTHS: SCHEDULE B
DYNAMIC CUT-THROUGH (TEST REQUIRED FOR INITIAL QUALIFICATION ONLY): TEST IN ACCORDANCE WITH
AS4373, METHOD 703. BLADE SHALL BE THE STANDARD CUTTING BLADE EXCEPT THE CUTTING EDGE RADIUS
SHALL BE 0.005 INCH ± 0.001 INCH. MINIMUM AVERAGE DYNAMIC CUT-THROUGH (LB) SHALL BE AS FOLLOWS:
WIRE SIZE 23 °C ± 5 °C 150 °C ± 5 °C 200 °C ± 5 °C
26 10 LB 8 LB 6 LB
20 25 LB 20 LB 15 LB
FLAMMABILITY: TEST IN ACCORDANCE WITH AS4373, METHOD 801.
REQUIREMENTS:
DURATION OF AFTER-FLAME 3 SECONDS (MAXIMUM)
FLAME TRAVEL 3.0 INCHES (MAXIMUM)
NO FLAMING OF TISSUE
Copyright SAE International
Provided by IHS under license with SAE
Not for ResaleNo reproduction or networking permitted without license from IHS
-
-
`
,
,
`
`
`
,
,
,
,
`
`
`
`
-
`
-
`
,
,
`
,
,
`
,
`
,
,
`
-
-
-
AEROSPACE STANDARD
(R) WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/
POLYIMIDE INSULATED, NORMAL WEIGHT, SILVER
COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER, ALLOY, 200 °C, 600 VOLTS
A
S2
27
59
/8
9
R
EV
.
B
AS22759/89
SHEET 4 OF 6
REV.
B
FORCED HYDROLYSIS: (TEST REQUIRED FOR INITIAL QUALIFICATION ONLY) 5000 HOURS AT 70 °C. TEST 5
UNCONDITIONED AND 5 CONDITIONED SAMPLES OF AWG SIZE 20 ONLY IN ACCORDANCE WITH SAE AS4373
METHOD 602. ALL SAMPLES MUST PASS THE DIELECTRIC TEST AS LISTED IN METHOD 602.
HIGH FREQUENCY SPARK TEST: (WHEN USED IN LIEU OF IMPULSE DIELECTRIC TEST) TEST IN ACCORDANCE
WITH AS4373, METHOD 505, 5.7 KILOVOLTS (RMS). TEST 100 PERCENT OF THE WIRE.
HUMIDITY RESISTANCE: AFTER HUMIDITY EXPOSURE WIRE SHALL MEET THE REQUIREMENTS FOR INITIAL
INSULATION RESISTANCE.
IDENTIFICATION OF PRODUCT: NOT REQUIRED FOR SIZE 26. COLOR CODE DESIGNATOR NOT REQUIRED.
IDENTIFICATION DURABILITY: 125 CYCLES (250 STROKES), 250 GRAMS WEIGHT.
IMMERSION (TEST REQUIRED FOR INITIAL QUALIFICATION ONLY): TEST IN ACCORDANCE WITH AS4373, METHOD
601 INCLUDING THE ADDITIONAL FLUIDS LISTED IN TABLE 5 OF THIS SPECIFICATION. USE MANDRELS AND
WEIGHTS LISTED IN TABLE 6 FOR BEND TESTING. DIELECTRIC TEST, 2500 VOLTS (RMS), 60 HZ. FOR TURBINE
FUEL IMMERSION TEST OF AS4373, EITHER JP4 OR MIL-DTL-83133 TYPE JP-8 (NATO TYPE F-34) MAY BE USED.
TABLE 5 - FLUID TABLE
TEST FLUID
TEST TEMPERATURE
(°C (°F))
IMMERSION
TIME (HOURS)
A. SAE AMS 1424, ANTI-ICING AND DEICING DEFROSTING FLUID,
UNDILUTED
48-50 (118-122) 20
B. SAE AMS 1424, ANTI-ICING AND DEICING DEFROSTING FLUID,
DILUTED 60/40 (FLUID/WATER) RATIO
48-50 (118-122) 20
C. MIL-C-43616, CLEANING COMPOUND, AIRCRAFT SURFACE, TYPE I 48-50 (118-122) 20
D. ASTM D 1153, METHYL ISOBUTYL KETONE (FOR USE IN ORGANIC
COATINGS)
20-25 (68-77) 168
E. SAE AS1241, FIRE RESISTANT HYDRAULIC FLUID FOR AIRCRAFT 48-50 (118-122) 20
F. MIL-PRF-7808, LUBRICATING OIL, AIRCRAFT TURBINE ENGINE,
SYNTHETIC BASE
118-121 (244-250) 30
G. MIL-PRF-87937, CLEANING COMPOUND, AEROSPACE EQUIPMENT,
TYPE II OR TYPE IV, UNDILUTED
63-68 (145-154) 20
H. MIL-PRF-87937, CLEANING COMPOUND, AEROSPACE EQUIPMENT,
TYPE II OR TYPE IV, DILUTED 25/75 (FLUID/WATER) RATIO
63-68 (145-154) 20
I. TT-S-735, STANDARD TEST FLUIDS: HYDROCARBON, TYPE I 20-25 (68-77) 168
J. TT-S-735, STANDARD TEST FLUIDS: HYDROCARBON, TYPE II 20-25 (68-77) 168
K. TT-S-735, STANDARD TEST FLUIDS: HYDROCARBON, TYPE IV 20-25 (68-77) 168
L. DIELECTRIC-COOLANT FLUID SYNTHETIC SILICATE ESTER BASE,
MONSANTO COOLANOL 25 OR APPROVED EQUIVALENT
20-25 (68-77) 168
M. ASTM D 4814, GASOLINE, AUTOMOTIVE, COMBAT 20-25 (68-77) 168
IMPULSE DIELECTRIC TEST: 8.0 KILOVOLTS (PEAK). TEST 100 PERCENT OF THE WIRE.
INSULATION RESISTANCE: 5000 MEGOHMS FOR 1000 FEET (MINIMUM).
INSULATION STATE OF SINTER: (QUALITY CONFORMANCE INSPECTION PERFORMED ON ONE SAMPLE PER LOT)
EVALUATE FP LAYERS WITH A DIFFERENTIAL SCANNING CALORIMETER PER AS4373, METHOD 813. THE
DIFFERENCE IN ENERGY TO MELT BETWEEN THE FIRST AND SECOND HEATS SHALL BE LESS THAN OR EQUAL
TO 3 JOULES/GRAM.
LAMINATION SEALING: (GROUP II QUALITY CONFORMANCE TEST) WHEN TESTED IN ACCORDANCE WITH AS4373,
METHOD 809 AT 260 °C FOR 6 HOURS, THERE SHALL BE NO EVIDENCE OF TAPE SEPARATION OR LIFTING. THREE
SAMPLES PER LOT SHALL BE TESTED.
LIFE CYCLE: 500 HOURS AT 230 °C ± 2 °C (446 °F ± 3.6 °F). DIELECTRIC TEST, 2500 VOLTS (RMS), 60 HZ. USE
MANDRELS COATED WITH POLYTETRAFLUOROETHYLENE SUCH THAT THE DIAMETER OF THE MANDRELS,
AFTER COATING, STILL CONFORM TO THE REQUIRED TEST MANDRELS DIAMETERS OF TABLE 6. AFTER OVEN
EXPOSURE, LAYERS SHALL NOT SEPARATE AND OR TAPES SHALL NOT LIFT ALONG THE INSULATION OR AT THE
ENDS.
Copyright SAE International
Provided by IHS under license with SAE
Not for ResaleNo reproduction or networking permitted without license from IHS
-
-
`
,
,
`
`
`
,
,
,
,
`
`
`
`
-
`
-
`
,
,
`
,
,
`
,
`
,
,
`
-
-
-
AEROSPACE STANDARD
(R) WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/
POLYIMIDE INSULATED, NORMAL WEIGHT, SILVER
COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER, ALLOY, 200 °C, 600 VOLTS
A
S2
27
59
/8
9
R
EV
.
B
AS22759/89
SHEET 5 OF 6
REV.
B
LOW TEMPERATURE (COLD BEND): USE MANDRELS AND WEIGHTS SPECIFIED IN TABLE 6. CHAMBER
TEMPERATURE, -65 °C ± 2 °C (-85 °F ± 3.6 °F). DIELECTRIC TEST, 2500 VOLTS (RMS), 60 HZ.
SHRINKAGE: 0.091 INCH (MAXIMUM) AT 230 °C ± 2 °C (446 °F ± 3.6 °F).
SMOKE: 200 °C ± 5 °C (392 °F ± 9 °F); NO VISIBLE SMOKE.
SOLDERABILITY: REQUIRED.
STRIPPABILITY: (GROUP II QUALITY CONFORMANCE TEST) AFTER STRIPPING WITH TOOLS AS DEFINED IN
AS22759 AND AS5457, NO FRAGMENTS OF ANY LAYER SHALL EXTEND MORE THAN 0.031 INCHES BEYOND THE
END OF THE POLYIMIDE TAPE LAYER.
INSULATION STRIP FORCE: (GROUP II QUALITY CONFORMANCE TEST). TEST IN ACCORDANCE WITH ASTM D
3032 SECTION 27. THE LENGTH OF THE INSULATION SLUGS SHALL BE 0.25 INCHES. STRIP FORCES (LB) SHALL
BE AS FOLLOWS. THERE SHALL BE NO EVIDENCE OF INSULATION LEFT ON THE CONDUCTOR WHEN VIEWED
WITH THE NAKED EYE.
WIRE SIZE MIN FORCE MAX FORCE
26-20 0.25 LB 6.0 LB
TAPE OVERLAP: IN ACCORDANCE WITH MIL-STD-2223, METHOD 6005.
TENSILE MODULUS: TEST COMPOSITE FILM IN ACCORDANCE WITH ASTM D 882, METHOD A.
THERMAL INDEX: 200 °C (392 °F) MINIMUM FOR 10,000 HOURS (TEST REQUIRED FOR INITIAL QUALIFICATION
ONLY). TEST SIZE 20 ONLY IN ACCORDANCE WITH ASTM D 3032, SECTION 14.
THERMAL SHOCK RESISTANCE: OVEN TEMPERATURE, 200 °C ± 2 °C (392 °F ± 3.6 °F), MAXIMUM CHANGE IN
MEASUREMENT, 0.091 INCHES. NO CRACKING.
UV LASER MARKING: (TEST REQUIRED FOR INITIAL QUALIFICATION ONLY) WHITE FP MATERIALS SHALL BE
FORMULATED IN SUCH A MANNER TO ACHIEVE A 55% MINIMUM CONTRAST LEVEL WHEN MARKED BY AN
ULTRAVIOLET (UV) LASER SOURCE OPERATING AT A FLUENCE OF 0.9 J/CM2 ± 0.1 J/CM2. THE CONTRAST LEVEL
SHALL BE EVALUATED IN ACCORDANCE WITH METHOD 711 OF AS4373. THE CONTRAST LEVEL IS DEFINED AS
(Reflectance of the background insulation - Reflectance of the laser mark)CL = x 100
Reflectance of the background insulation
WRAP (MANDREL WRAP): NO CRACKING, NO DIELECTRIC BREAKDOWN. USE MANDRELS SPECIFIED IN TABLE 6.
DIELECTRIC TEST, 2500 VOLTS (RMS), 60 HZ.
TABLE 6 - TEST MANDREL AND TEST LOAD REQUIREMENTS
TEST MANDREL DIAMETER 1/
(INCHES)
TEST LOAD 1/
(LB) WIRE
SIZE
(AWG) COLD BEND
LIFE CYCLE/
BEND TEST WRAP COLD BEND
LIFE CYCLE/
BEND TEST
26
24
22
20
1.00
1.00
1.00
1.00
0.375
0.500
0.500
0.500
0.125
0.125
0.125
0.125
3.00
3.00
4.00
4.00
0.50
0.75
1.00
1.50
1/ TOLERANCE SHALL BE ±3 PERCENT OF THE GIVEN VALUES.
Copyright SAE International
Provided by IHS under license with SAE
Not for ResaleNo reproduction or networking permitted without license from IHS
-
-
`
,
,
`
`
`
,
,
,
,
`
`
`
`
-
`
-
`
,
,
`
,
,
`
,
`
,
,
`
-
-
-
AEROSPACE STANDARD
(R) WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/
POLYIMIDE INSULATED, NORMAL WEIGHT, SILVER
COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH
COPPER, ALLOY, 200 °C, 600 VOLTS
A
S2
27
59
/8
9
R
EV
.
B
AS22759/89
SHEET 6 OF 6
REV.
B
QUALIFICATION OF WIRE:
FOR QUALIFICATION, A SOURCE IS REQUIRED TO SUBMIT DATA ON QUALITY CONFORMANCE TESTS AND ANY
FINISHED WIRE TESTS AS REQUIRED BY THE QUALIFICATION AUTHORIZATION LETTER. ALL OTHER TESTING
WILL BE PERFORMED BY THE QUALIFYING ACTIVITY AT THE SOURCE’S EXPENSE.
DUE TO THE EXTENDED TIME PERIOD OVER WHICH THE THERMAL INDEX TEST IS PERFORMED, A SOURCE MAY
BECOME QUALIFIED UNDER THIS SPECIFICATION SHEET WHILE THIS TEST IS STILL IN PROGRESS.
NOTES:
THE CHANGE BAR ( l ) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING
AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE
OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION
OF THE DOCUMENT.
Copyright SAE International
Provided by IHS under license with SAE
Not for ResaleNo reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---