4oxv电化学氧气传感器
4OXV CiTiceL?
Oxygen (O2) Gas SensorPart Number: AAY80-390Key Features and Benefits: ? False alarm immunity ? Enhanced response time in extreme applications ? Reliably meets stated life ? Superior environmental performance
MEASUREMENT
TechnologyElectrochemicalMeasurement Range1-25% vol. O2Maximum Overload30% vol. O2Output Signal0.10 ? 0.02 mA in AirResponse Time (T90)<15 SecondsZero Current (Offset)<0.6% vol. O2LinearityCan be considered linear in
many cases.
See Operating Principles
(OP-02) for further details.
ELECTRICAL
Recommended Load Resistor100 ? MECHANICAL
Casing Material ABSWeight <16 gOrientation Sensitivity<0.2% vol. O2 equivalent
ENVIRONMENTAL
Operating Temperature Range-20?C to +50?C (up to 3 months
continuous across RH range)Recommended Storage Temp0?C to ———————————————————————————————————————————————
20?CThermal Transient<23.5% vol. O2(Temp. plunge +22?C to -20?C)
Operating Pressure RangeAtmospheric ? 20%Pressure
Coefficient<0.02% signal/mbarPressure Transient<200% signal change(60 cm H2O step change) Relative Humidity Range(at 0?C to 20?C)Continuous5 to 95%RH non-condensingShort Term0 to 99%RH non-condensing
LIFETIME
Long Term Output Drift<2% signal/month
Typically <5% over operating life
Expected Operating LifeMinimum 24 months in air
Storage Life6 months in original packaging
Warranty Period24 months from date of despatchIMPORTANT NOTESObstruction of the vent hole will compromise performance, and must be avoided. Do not remove label.Adequate free volume should be provided below the sensor to ensure full performance. All tolerances ?0.15 mm unless otherwise stated. DO NOT solder to pins.All performance data is based on conditions at 20oC, 50% RH and 1013 mbar.
General purpose, portable or fixed life safety.
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting ———————————————————————————————————————————————
into instruments, and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Toxic gases at TLV levels will have no cross-sensitivity effect on Oxygen CiTiceLs. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.
IMPORTANT NOTE: Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2. Oxygen CiTiceLs are not suitable for continuous operation in concentrations of CO2 above 25%.
SAFETY NOTE in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out such tests may jeopardize the safety of people and property.
Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company’s policy of continued product improvement City Technology Limited ———————————————————————————————————————————————
reserves the right to make product changes without notice. No liability is accepted for any consequential losses, injury or damage resulting from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitute a specification or an offer for sale. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics
quoted. As the products may be used by the client in circumstances beyond the knowledge and control of City Technology Limited, we cannot give any warranty as to the relevance of these particulars to an application. It is the clients’ responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application.
———————————————————————————————————————————————