为了正常的体验网站,请在浏览器设置里面开启Javascript功能!
首页 > EN 1233

EN 1233

2012-09-17 14页 pdf 131KB 17阅读

用户头像

is_087004

暂无简介

举报
EN 1233 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITIS...
EN 1233
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 1233 : 1997 BS 6068 : Section 2.38 : 1997 The European Standard EN 1233 : 1996 has the status of a British Standard ICS 13.060.01 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Water quality Ð Determination of chromium Ð Atomic absorption spectrometric methods BS EN 1233 : 1997 This British Standard, having been prepared under the direction of the Health and Environment Sector Board, was published under the authority of the Standards Board and comes into effect on 15 January 1997  BSI 1997 The following BSI references relate to the work on this standard: Committee reference EH/3/2 Draft for comment 93/508225 DC ISBN 0 580 26789 X Amendments issued since publication Amd. No. Date Text affected Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee EH/3, Water quality, to Subcommittee EH/3/2, Physical, chemical and biochemical methods, upon which the following bodies were represented: British Agrochemicals Association Ltd. British Ceramic Research British Gas plc British Soft Drinks Association Ltd. Chemical Industries' Association Convention of Scottish Local Authorities Department of the Environment (Water Directorate) Environment agency GAMBICA (BEAMA Ltd.) Industrial Water Society Laboratory of the Government Chemist Royal Society of Chemistry Soap and Detergent Industry Association Society of Chemical Industry Swimming Pool and Allied Trades Association Ltd. Water Companies Association Water Research Centre Water Services Association of England and Wales BS EN 1233 : 1997  BSI 1997 i Contents Page Committees responsible Inside front cover National foreword ii Foreword 2 Method Introduction 3 1 Scope 3 2 Normative references 3 3 Determination of chromium by flame atomic absorption spectrometry 3 4 Determination of chromium by electrothermal atomization atomic absorption spectrometry 6 Annex A (informative) Information on pretreatment and digestion of sludge and sediment samples 8 Tables 1 Precision data for clause 3 5 2 Interfering ions 5 3 Precision data for clause 4 7 ii  BSI 1997 BS EN 1233 : 1997 National foreword This British Standard has been prepared by Technical Committee EH/3 and is the English language version of EN 1233 Water quality Ð Determination of chromium Ð Atomic absorption spectrometric methods, published by the European Committee for Standardization (CEN). It supersedes BS 6068 : Section 2.38 : 1990, which is withdrawn. NOTE. The tests described in this British Standard should only be carried out by suitably qualified persons with an appropriate level of chemical expertise. Standard chemical procedures should be followed throughout. Cross-references Publication referred to Corresponding British Standard BS 6068 Water quality Part 6 Sampling EN 25667-2 : 1993 Section 6.2 : 1991 Guidance on sampling techniques ISO 5667-3 : 1994 Section 6.3 : 1996 Guidance on the preservation and handling of samples Compliance with a British Standard does not of itself confer immunity from legal obligations. CEN European Committee for Standardization Comite EuropeÂen de Normalisation EuropaÈisches Komitee fuÈ r Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels  1996 All rights of reproduction and communication in any form and by any means reserved in all countries to CEN and its members Ref. No. EN 1233 : 1996 E EUROPEAN STANDARD EN 1233 NORME EUROPE ENNE EUROPAÈ ISCHE NORM July 1996 ICS 13.060.40 Descriptors: water, quality, chemical analysis, determination of content, chromium, atomic absorption spectrometry English version Water quality Ð Determination of chromium Ð Atomic absorption spectrometric methods Qualite de l'eau Ð Dosage du chrome Ð MeÂthodes par spectromeÂtrie d'absorption atomique Wasserbeschaffenheit Ð Bestimmung von Chrom Ð Verfahren mittels Atomabsorptionsspektrometrie This European Standard was approved by CEN on 1996-05-16. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Page 2 EN 1233 : 1996  BSI 1997 Foreword This European Standard has been prepared by the Technical Committee CEN/TC 230, Water analysis, the Secretariat of which is held by DIN. Annex A is informative. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 1997, and conflicting national standards shall be withdrawn at the latest by January 1997. In accordance with the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. On the elaboration of this European Standard, the revision of the International Standard ISO 9174 has been started simultaneously with the intention to harmonize both standards. Page 3 EN 1233 : 1996  BSI 1997 Introduction Chromium occurs in water in the oxidation states III and VI. The two methods described determine chromium in both oxidation states, either as acid soluble chromium or as water soluble chromium, depending on the sample pretreatment. The method chosen depends on the concentration of chromium in the water to be examined. Some information is given in an informative annex on pretreatment and digestion of chromium from sludges and sediments. 1 Scope This European Standard specifies two methods for the determination of chromium in water by atomic absorption spectrometry. The two methods are covered in separate clauses as follows: ± clause 3: Determination of chromium by flame atomic absorption spectrometry; ± clause 4: Determination of chromium by electrothermal atomization atomic absorption spectrometry. Clause 3 is applicable to the analysis of water and waste water when the concentration range is between 0,5 mg/l and 20 mg/l of chromium. When the concentration is below 0,5 mg/l, the determination can be carried out after carefully evaporating an acidified sample to small volume, taking care to avoid the formation of a precipitate. WARNING: The use of evaporation will increase the effect of interfering substances and therefore for concentrations below 0,1 mg/l the method in clause 4 is given. Clause 4 is applicable to the analysis of water and waste water when the concentration range is between 5 mg/l and 100 mg/l of chromium by injecting a sample volume of 20 ml. It is applicable to the determination of higher concentrations by using a smaller sample volume. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. EN 25667-2 : 1993 Water quality Ð Sampling Ð Part 2: Guidance on sampling techniques (ISO 5667-2 : 1991) EN ISO 5667-3 : 1995 Water quality Ð Sampling Ð Part 3: Guidance on the preservation and handling of samples (ISO 5667-3 : 1994) 3 Determination of chromium by flame atomic absorption spectrometry 3.1 Principle The method is based on the atomic absorption spectrometric measurement of the chromium content of the acidified sample in a nitrous oxide/acetylene flame. Measurement at a wavelength of 357,9 nm. Addition of lanthanum salt to reduce matrix interferences is necessary. 3.2 Reagents 3.2.1 General All reagents shall be of recognized analytical grade. Use deionized water or water distilled from an all glass apparatus. The water used for blank tests and for preparing reagents and standard solutions shall have a chromium content that is negligible compared with the smallest concentrations to be determined in the samples. 3.2.2 Hydrochloric acid, HCl, r ≈ 1,18 g/ml. 3.2.3 Nitric acid, HNO3, r ≈ 1,42 g/ml. 3.2.4 Nitric acid, c(HNO3) = 1,5 mol/l. Introduce about 500 ml of water into a 1000 ml volumetric flask, add 100 ml of nitric acid (see 3.2.3) and dilute to the mark with water. 3.2.5 Hydrogen peroxide, H2O2,30 % (m/m) solution. 3.2.6 Lanthanum chloride, (LaCl3), solution with r(La) = 20 g/l. Dissolve 23,5 g of lanthanum oxide La2O3, in 200 ml of hydrochloric acid (see 3.2.2), dilute to 1000 ml with water and mix. Appropriate precautions shall be observed when preparing this solution because the reaction of La2O3 with hydrochloric acid is strongly exothermic. 3.2.7 Chromium solutions 3.2.7.1 Chromium, stock solution, with r(Cr) = 1,000 g/l. Dry a portion of potassium dichromate (K2Cr2O7) at 105 ÊC ± 2 ÊC for about 2 h. Cool and dissolve 2,825 g ± 0,001 g of the dried potassium dichromate in water. Add 5 ml ± 1 ml of nitric acid (see 3.2.3) and dilute to 1000 ml with water in a volumetric flask. 1 ml of this stock solution contains 1,00 mg of chromium. Store this solution in either polyethene or borosilicate glass containers at room temperature. The solution is stable at room temperature for about 1 year if it is stored in the dark and at a pH between 1 and 2. NOTE. Chromium stock solutions are commercially available. Page 4 EN 1233 : 1996  BSI 1997 3.2.7.2 Chromium, standard solution with r(Cr) = 50 mg/l. Introduce 50,00 ml ± 0,01 ml of the chromium stock solution (see 3.2.7.1) into a 1000 ml volumetric flask. Add 1 ml of nitric acid (see 3.2.3), make up to the mark with water and mix. This solution is stable for at least 1 month. 3.3 Apparatus 3.3.1 Atomic absorption spectrometer, equipped with a chromium hollow cathode lamp and a nitrous oxide/acetylene burner, and operated in accordance with the manufacturer's instructions. It is essential that the manufacturer's safety recommendations are strictly observed when using the nitrous oxide/acetylene flame. 3.3.2 Glassware Before use, carefully soak all glassware for about 24 h in nitric acid (see 3.2.4), then rinse thoroughly with water. If low concentrations are expected (for example in ground water), the glassware should be kept under nitric acid (see 3.2.4) until use. Do not use glassware which has been cleaned with chromic acid. 3.3.3 Membrane filters, of nominal pore diameter 0,45 mm, washed thoroughly with nitric acid (see 3.2.4) and rinsed with water (see 3.2.1). 3.4 Sampling and preparation of test portions 3.4.1 General Collect and preserve samples according to EN 25667-2 and EN ISO 5667-3. See also annex A. Collect samples in high density polyethene or borosilicate glass containers which have been previously cleaned with nitric acid (see 3.2.4) and then rinsed with water (see 3.2.1). 3.4.2 Acid soluble chromium Treat the samples by addition of sufficient nitric acid (see 3.2.3), immediately after collection, to adjust the pH to between 1 and 2. To 90 ml of the acidified sample, or another suitable aliquot in accordance with the expected concentration, add 1 ml of hydrogen peroxide (see 3.2.5) and 2 ml of nitric acid (see 3.2.3). Boil and evaporate to a volume of approximately 50 ml. The sample shall not be reduced to dryness. In the case of samples with low chromium concentrations this digestion method should be carried out in an autoclave or a microwave oven. It is important to follow the manufacturer's instructions. Add 10 ml of nitric acid (see 3.2.3) to the evaporated solution. Transfer the solution to a 100 ml volumetric flask. Add 10 ml of lanthanum chloride solution (see 3.2.6) into the flask, dilute to the mark with water and mix. 3.4.3 Water soluble chromium Filter the sample through a membrane filter (see 3.3.3), as soon as possible after collection, and acidify the filtrate immediately with nitric acid (see 3.2.3) to give a pH between 1 and 2. Add 10 ml of lanthanum chloride solution (see 3.2.6) to a 100 ml volumetric flask and make up to the mark with the acidified filtrate, or use another suitable aliquot in accordance with the expected concentration, and mix. 3.5 Procedure 3.5.1 Blank test Carry out a blank test in parallel with the determination by the same procedure and using the same quantities of all the reagents as in the sampling and determination, but replacing the test portion by water. 3.5.2 Preparation of the calibration solutions Before each set of determinations, prepare from the chromium standard solution (see 3.2.7.2) at least five calibration solutions covering the range of concentrations to be determined; for example: pipette 1,0 ml, 2,5 ml, 5,0 ml, 10,0 ml and 20,0 ml of chromium standard solution (see 3.2.7.2) into a series of 100 ml volumetric flasks. Add to each flask depending on the pretreatment (see 3.4.2 and 3.4.3) 10 ml or 2 ml of nitric acid (see 3.2.3) respectively and 10 ml of lanthanum chloride solution (see 3.2.6), dilute to the mark with water and mix. These solutions correspond to chromium concentrations of 0,50 mg/l, 1,25 mg/l, 2,50 mg/l, 5,00 mg/l and 10,0 mg/l respectively. Proceed accordingly for other concentration ranges of interest. 3.5.3 Calibration Set up the instrument in accordance with the manufacturer's instructions (at wavelength l = 357,9 nm) using a nitrous oxide/acetylene flame. Aspirate a calibration solution (see 3.5.2) and optimize the aspiration, the burner height and the flame conditions. Adjust the response of the instrument to zero absorbance with water. In turn, aspirate the set of calibration solutions (see 3.5.2) and the blank solution (see 3.5.1). Plot a graph having the chromium concentrations of the calibration solutions in milligrams per litre as abscissa and the corresponding absorbance values as ordinate. Alternatively, data processing facilities can be used to equate the concentration against the absorbance. 3.5.4 Test portion measurement Aspirate the prepared test portion (see 3.4.2 or 3.4.3) into the flame and measure the absorbance for chromium. After each measurement aspirate water and readjust the zero, if necessary. Page 5 EN 1233 : 1996  BSI 1997 Table 1. Precision data for clause 3 Type of sample l n xS X y sr VCr sR VCR Standard solution 11 43 15,0 14,64 97,5 0,084 0,6 0,798 5,5 Water with added concentration 14 56 2,0 2,06 103,0 0,053 2,6 0,218 10,6 where: l is the number of laboratories; n is the number of measured values (without outliers); xS is the concentration of samples, in milligrams per litre; X is the overall mean, in milligrams per litre; y is the recovery rate, in percent; sr is the repeatability standard deviation, in milligrams per litre; VCr is the repeatability variation coefficient, in percent; sR is the reproducibility standard deviation, in milligrams per litre; VCR is the reproducibility variation coefficient, in percent. 3.6 Expression of results 3.6.1 By reference to the calibration graph obtained (see 3.5.3) or data processing facilities used, determine the concentration of chromium corresponding to the absorbances of the test portion (see 3.5.4) and of the blank solution (see 3.5.1). Calculate the concentration of chromium of the sample using the equation r = (As 2 ASO)VW VPb where: r is the chromium concentration of the sample, in milligrams per litre; AS is the absorbance of the test portion; ASO is the absorbance of the blank; VP is the volume of the acidified sample in accordance with 3.4.2 or 3.4.3, respectively, in millilitres; b is the sensitivity (slope of the calibration graph) in litres per milligram; VW is the volume of the test portion according to 3.4.2 or 3.4.3 respectively, in millilitres. 3.6.2 Precision data An interlaboratory test carried out in January 1985 yielded the data given in table 1. The standard solution used was made from deionized water, spiked with chromium. The water used was a municipal, biologically treated waste water, spiked with chromium. The digestion as described in 3.4.2 was applied; in the atomic absorption spectrometer apparatus, a hollow cathode lamp was used. 3.7 Interferences The following ions have been tested and shown not to cause interference below the concentration given in table 2. This information was taken from practical tests carried out in a working group in 1984. Table 2. Interfering ions Ion Concentration Ion Concentration mg/l mg/l Sulfate 10 000 Iron 500 Chloride 12 000 Nickel 100 Sodium 9 000 Copper 100 Potassium 9 000 Cobalt 100 Magnesium 2 000 Aluminium 100 Calcium 2 000 Zinc 100 The total dry residue of the sample shall not exceed 15 g/l and the conductivity should be lower than 2000 mS/m. NOTE. It is possible to determine the effect of possible interferences by analysing samples spiked with chromium and various concentrations of the potential interfering substance using the method of standard additions. 3.8 Test report The test report shall contain at least the following information: a) a reference to this European Standard; b) a reference to the procedure used; c) complete identification of the sample; d) any other information relevant to the procedure. Page 6 EN 1233 : 1996  BSI 1997 4 Determination of chromium by electrothermal atomization atomic absorption spectrometry 4.1 Principle Chromium is determined directly in acidified samples by electrothermal atomization atomic absorption spectrometry. The sample is introduced into an electrically heated graphite tube and the absorbance is measured at a wavelength of 357,9 nm. If necessary, the standard additions technique is employed. 4.2 Reagents 4.2.1 See 3.2. 4.2.2 Chromium standard solution, with r(Cr) = 0,5 mg/l. Add 10,00 ml ± 0,01 ml of the chromium standard solution (see 3.2.7.2) to a 1000 ml volumetric flask. Add 10 ml of nitric acid (see 3.2.3) and dilute to the mark with water. This solution is stable for at least 1 month. 4.3 Apparatus 4.3.1 Atomic absorption spectrometer, equipped with an electrothermal atomizer, chromium hollow cathode lamp and a suitable device for correction of non-specific absorbants. 4.3.2 Atomizer tubes The atomizer tubes will vary according to the instrument used but shall be pyrolytically coated and pre-conditioned before use in accordance with the manufacturer's instructions. NOTE. It is permissible to use a L'vov platform. 4.3.3 Automatic sample injector (autosampler) or micro-syringe, of appropriate volume. For high precision, an automatic sample injector is necessary. 4.4 Sampling and preparation of test portions Follow the procedures described in 3.4 but omit the lanthanum chloride solution. Because of the very low levels of chromium being determined, take particular care to avoid any contamination at all stag
/
本文档为【EN 1233】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索