为了正常的体验网站,请在浏览器设置里面开启Javascript功能!

MTL安全栅系列

2013-05-01 30页 pdf 440KB 251阅读

用户头像

is_003046

暂无简介

举报
MTL安全栅系列 EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are su...
MTL安全栅系列
EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice for close integration of IS circuits into process- connected systems MTL4500 SERIES Based on proven IS isolation technology, MTL4500 Series modules do not need a high integrity earth and the associated circuits can be left floating or be earthed at any one point in accordance with good earthing practices. MTL4500 Series provides single channel single loop integrity across the range with the addition of dual channel options for the switch/proximity modules, analogue inputs and analogue outputs. There is even a quad channel switch/proximity input module for the maximum channel density. Line fault detection (LFD) facilities are provided across the range of I/O functions; on the switch/proximity detectors, the MTL4523 solenoid/alarm driver and the isolating drivers. Analogue input units such as the MTL4541 provide line fault detection by repeating o/c or s/c currents to the safe-area control system. System backplanes are located in safe areas and, because the hazardous-area circuits are connected directly to the modules, do not need to be certified. See MTL series backplanes, enclosures and accessories for full details. The easy migration from MTL4000 supports existing installations because MTL4500 modules can be mounted on backplanes that were designed for MTL4000. A simple modification uses the backplane mounting holes of the MTL4000 to accept the mounting clips for the MTL4500 modules. This ensures continued availability and operation of process plant with new I/O modules and enhanced functionality. The MTL4500 Series of isolating interface units introduces key concepts for integrating intrinsic safety into large or medium sized process-connected systems. Being exceptionally compact, the units give high packing densities and plug into system backplanes with safe-area connections made by multiway connectors – an approach which not only simplifies engineering but also reduces installation and maintenance costs. MTL4500 modules are held on the backplane with plastic clips that are simple to use, secure in operation and avoid the use of screws, giving further reduction in installation and maintenance time and cost. Input and output modules handle normal process applications covering on/off or analogue signals between hazardous-area equipment and safe-area systems. Modules incorporate proven intrinsically safe isolation techniques, internationally certified for protecting equipment and wiring in all zones and explosive atmospheres. Input, output and power-supply circuits are isolated from each other, giving maximum flexibility for control loop applications. Key module design features include a multiway connector to the backplane for safe-area and power supply connections. Hazardous-area connections simply plug into the front of the module; this simplifies installation and maintenance and reduces time, cost, and the risk of errors. Status LEDs, configuration switches and ports are located on the top or side of individual modules for easy access. The compact, 16mm wide, design reduces weight and gives exceptionally high packing density. ♦♦ System backplanes with bussed power and safe-area connections ♦♦ Custom-designed backplanes for closest integration into process- connected systems ♦♦ Compatible with MTL4000 Series interface family ♦♦ Compact modular design with ‘plug-in’ connections ♦♦ Quick install and release mechanism ♦♦ High module/channel packing densities EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice MTL4500 I/O MODULE LIST DIGITAL INPUT Part Number Functions MTL4510 4ch DI solid-state output MTL4510B 4ch DI multifunction solid-state output MTL4511 1ch DI relay output MTL4513 2ch DI solid-state output MTL4514 1ch DI relay output + LFD alarm MTL4516 2ch DI relay output MTL4516C 2ch DI with changeover relay output MTL4517 2ch DI relay output + LFD alarm DIGITAL OUTPUT Part Number Functions MTL4521 Loop powered solenoid driver MTL4523 Solenoid driver with LFD MTL4523R Solenoid driver with LFD MTL4523L Loop powered solenoid driver + LFD MTL4524 Switch operated solenoid driver MTL4524S Switch operated solenoid driver, 24V override MTL4525 Switch operated solenoid driver low power ANALOGUE INPUT Part Number Functions MTL4541 1ch 2/3 wire Transmitter repeater MTL4541B 1ch 2/3 wire Transmitter repeater, 2 port isolation MTL4541P 1ch 2/3 wire Transmitter repeater, high power MTL4544 2ch 2/3 wire Transmitter repeater MTL4544B 2ch 2/3 wire Transmitter repeater, 2 port isolation ANALOGUE OUTPUT Part Number Functions MTL4546 1ch 4-20mA smart isolating driver + LFD MTL4546C 1ch 4-20mA smart isolating driver + oc LFD MTL4549 2ch 4-20mA smart isolating driver + LFD MTL4549C 2ch 4-20mA smart isolating driver + oc LFD � � TEMPERATURE INPUT Part Number Functions MTL4575 Temperature converter GENERAL Part Number Functions MTL4599 Dummy isolator MTL4599N General purpose feed-through module EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice EPS4510-1 MTL4510 SWITCH/ PROXIMITY DETECTOR INTERFACE four-channel, digital input Hazardous area Safe area � � � � � � � � � � � � � � � ���� �� �� ��� ��� � ������� ���� ���� � � � � ���� ���� � �� ��� � �� ��� � �� ������� � � � The MTL4510 enables four solid-state outputs in the safe area to be controlled by up to four switches or proximity detectors located in a hazardous area. Each pair of output transistors shares a common terminal and can switch +ve or –ve polarity signals. A range of module configurations is available (see Table 1) through the use of selector switches. When proximity detector modes are selected, LFD is enabled and the output switches to OFF if a line fault is detected. SPECIFICATION See also common specification Number of channels 4, configured by switches Location of switches Zone 0, IIC, T6 hazardous area Div 1, Group A hazardous location Location of proximity detectors Zone 0, IIC, T4-6 hazardous area if suitably certified Div 1, Group A, hazardous location Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Voltage applied to sensor 7 to 9V dc from 1k: ±10% Input/output characteristics Normal phase Outputs closed if input > 2.1mA (< 2k: in input circuit) Outputs open if input < 1.2mA (> 10k: in input circuit) Hysteresis: 200µA (650:) nominal Line fault detection (LFD) (when selected) User-selectable via switches on the side of the unit. Open-circuit alarm on if Iin < 50µA Open-circuit alarm off if Iin > 250µA Short-circuit alarm on if Rin < 100: Short-circuit alarm off if Rin > 360: Note: Resistors must be fitted when using the LFD facility with a contact input 500: to 1k: in series with switch 20k: to 25k: in parallel with switch Safe-area outputs Floating solid-state outputs compatible with logic circuits Operating frequency: dc to 500Hz Max. off-state voltage: ± 35V Max. off-state leakage current: ± 50µA Max. on-state resistance: 65: Max. on-state current: ± 50mA LED indicators Green: power indication Yellow: four: indicates output active Red: indicates line fault + faulty channel’s yellow LED flashes Maximum current consumption 40mA at 24V (with all output channels energised) Power dissipation within unit 0.96W at 24V Safety description (each channel) Vo=10.5V Io=14mA Po=37mW Um = 253V rms or dc Terminal Function 1 Input channel A 2 Input channel AB common (+) 3 Input channel B 4 Input channel C 5 Input channel CD common (+) 6 Input channel D 7 Output channel 1 8 Output channel 1/2 common 9 Output channel 2 10 Output channel 3 11 Output channel 3/4 common 12 Output channel 4 13 Supply –ve 14 Supply +ve Table 1 - Mode options See Instruction Manual INM4500 for further mode information. MODE o/p 1 o/p 2 o/p 3 o/p 4 0 chA chB chC chD 1 chA rev. chB chC chD 2 chA chB rev. chC chD 3 chA chB chC rev. chD 4 chA chB chC chD rev. 5 chA rev. chB chC rev. chD 6 chA chB rev. chC chD rev. 7 chA rev. chB rev. chC rev. chD rev. 8 chA chB chC chD 9 chA rev. chB chC chD 10 chA chB rev. chC chD 11 chA chB chC rev. chD 12 chA chB chC chD rev. 13 chA rev. chB chC rev. chD 14 chA chB rev. chC chD rev. 15 chA rev. chB rev. chC rev. chD rev. i/p type switch prox. detector + LFD EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice EPS4510B - 1 MTL4510B SWITCH/ PROXIMITY DETECTOR INTERFACE four-channel, multi-function, digital input Hazardous area Safe area � � � � � � � � � � � � � � � ���� �� �� ��� ��� � ������� ���� ���� � � � � ���� ���� � �� ��� � �� ��� � �� ������� � � � The MTL4510B enables four solid-state outputs in the safe area to be controlled by up to four switches or proximity detectors located in a hazardous area. Each pair of output transistors shares a common terminal and can switch +ve or –ve polarity signals. A range of module configurations is available (see Table 1) through the use of selector switches. These include start/stop operations and pulse output modes. SPECIFICATION See also common specification Number of channels 4, configured by switches Location of switches Zone 0, IIC, T6 hazardous area Div 1, Group A hazardous location Location of proximity detectors Zone 0, IIC, T4-6 hazardous area if suitably certified Div 1, Group A, hazardous location Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Voltage applied to sensor 7 to 9V dc from 1k: ±10% Input/output characteristics Normal phase Outputs closed if input > 2.1mA (< 2k: in input circuit) Outputs open if input < 1.2mA (> 10k: in input circuit) Hysteresis: 200µA (650:) nominal Line fault detection (LFD) (when selected) User-selectable via switches on the side of the unit. Open-circuit alarm on if Iin < 50µA Open-circuit alarm off if Iin > 250µA Short-circuit alarm on if Rin < 100: Short-circuit alarm off if Rin > 360: Note: Resistors must be fitted when using the LFD facility with a contact input 500: to 1k: in series with switch 20k: to 25k: in parallel with switch Safe-area outputs Floating solid-state outputs compatible with logic circuits Operating frequency: dc to 500Hz Max. off-state voltage: ± 35V Max. off-state leakage current: ± 50µA Max. on-state resistance: 65: Max. on-state current: ± 50mA LED indicators Green: power indication Yellow: four: indicates output active Red: LFD indication + faulty channel’s yellow LED flashes Maximum current consumption 40mA at 24V (with all output channels energised) Power dissipation within unit 0.96 W at 24V Safety description (each channel) Vo=10.5V Io=14mA Po=37mW Um = 253V rms or dc Terminal Function 1 Input channel A 2 Input channel AB common (+) 3 Input channel B 4 Input channel C 5 Input channel CD common (+) 6 Input channel D 7 Output channel 1 8 Output channel 1/2 common 9 Output channel 2 10 Output channel 3 11 Output channel 3/4 common 12 Output channel 4 13 Supply –ve 14 Supply +ve Table 1 - Mode options See Instruction Manual INM4500 for further mode information. MODE Function Equivalent 0 4-ch switch input, MTL4510 1 2-ch each channel one input, two outputs MTL4016 2 Same as mode 1 with phase reversed MTL4016 3 2-ch, 2-pole changeover output 4 1-ch with line fault output MTL4014 5 As mode 4 with changeover outputs 6 1-ch with start-stop latch MTL2210B 7 4-ch switch input, MTL4510 8 4-ch switch input, MTL4510 9 2-ch with line fault output MTL4017 10 As mode 9 with LFD changeover 11 As mode 10 with phase reversed 12 3-ch with normally-open LFD output 13 3-ch with normally-closed LFD output 14 2-ch monostable, pulse stretcher 15 4-ch switch input MTL4510 EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice MTL4511 SWITCH/ PROXIMITY DETECTOR INTERFACE single channel, with line fault detection The MTL4511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line-fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts. SPECIFICATION See also common specification Number of channels One Location of switches Zone 0, IIC, T6 hazardous area Div. 1, Group A hazardous location Location of proximity detector Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Voltage applied to sensor 7 to 9V dc from 1k: ±10% Input/output characteristics Normal phase Outputs closed if input > 2.1mA (< 2k: in input circuit) Outputs open if input < 1.2mA (> 10k: in input circuit) Hysteresis: 200µA (650:) nominal Line fault detection (LFD) (when selected) User-selectable via switches on the side of the unit. A line fault is indicated by an LED. The channel output relay is de-energised if an input line fault is detected. Open-circuit alarm on if Iin < 50µA Open-circuit alarm off if Iin > 250µA Short-circuit alarm on if Rin < 100: Short-circuit alarm off if Rin > 360: Note: Resistors must be fitted when using the LFD facility with a contact input 500: to 1k: in series with switch 20k: to 25k: in parallel with switch Safe-area output Single pole relay with changeover contacts Note: reactive loads must be adequately suppressed Relay characteristics Response time: 10ms maximum Contact rating: 10W, 0.5A, 35V dc LED indicators Green: power indication Yellow: channel status, on when output is energised Red: LFD indication, on when line fault is detected Maximum current consumption 30mA at 24V Power dissipation within unit 0.72W at 24V Safety description (each channel) Vo=10.5V Io=14mA Po=37mW Um = 253V rms or dc Hazardous area � � � � � � � � � � � � � � � � � ���� �� �� ��� ��� � ������� �� � � � !��"!#�$%&���'$% %($��$�$���& )*+���,�-�$��$���&� &$.�+&$�&$�+���&� +/�#0��+���$'$��$� ������ Safe area EPS4511-1 Terminal Function 1 Input –ve 2 Input +ve 3 To earth leakage detector 7 Output normally-open contact 8 Common 9 Output normally-closed contact 13 Supply –ve 14 Supply +ve EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice EPS4513-1 The MTL4513 enables two solid-state outputs in the safe area to be controlled by two switches or proximity detectors located in the hazardous area. The Ch1/Ch2 output transistors share a common terminal and can switch +ve or -ve polarity signals. Independent output phase reversal and line fault detection are enabled via switches for each output. LFD indication is provided on the top of the module. SPECIFICATION See also common specification Number of channels Two Location of switches Zone 0, IIC, T6 hazardous area Div. 1, Group A hazardous location Location of proximity detectors Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Voltage applied to sensor 7 to 9V dc from 1k: ±10% Input/output characteristics Normal phase Outputs closed if input > 2.1mA (< 2k: in input circuit) Outputs open if input < 1.2mA (> 10k: in input circuit) Hysteresis: 200µA (650:) nominal Line fault detection (LFD) (when selected) User-selectable for each channel via switches on the side of the unit. Line faults are indicated by an LED for each channel. Open-circuit alarm on if Iin < 50µA Open-circuit alarm off if Iin > 250µA Short-circuit alarm on if Rin < 100: Short-circuit alarm off if Rin > 360: Note: Resistors must be fitted when using the LFD facility with a contact input 500: to 1k: in series with switch 20k: to 25k: in parallel with switch Phase reversal Independent for each channel, user-selectable Safe-area outputs Floating solid-state outputs compatible with logic circuits Operating frequency: dc to 1kHz Max. off-state voltage: ± 35V Max. off-state leakage current: ± 50µA Max. on-state resistance: 65: Max. on-state current: ± 50mA MTL4513 SWITCH/ PROXIMITY DETECTOR INTERFACE two-channel, with line fault detection and phase reversal Hazardous area Safe area � � � � � � � � � � � � � � � � � � � ���� �� �� ��� ��� � ������� ���� ���� ���� ���� �� � � � �� � � � !��"!#�$%&���'$% %($��$�$���& )*+���,�-�$��$���&� &$.�+&$�&$�+���&� +/�#0��+���$'$��$� LED indicators Green: power indication Yellow: two: channel status, on when outputs are on Red: two: LFD indication, on when line fault detected Maximum current consumption 30mA at 24V Power dissipation within unit 0.9W typical at 24V with 10mA loads- 1.2W max. with 50mA loads Safety description (each channel) Vo=10.5V Io=14mA Po=37mW Um = 253V rms or dc Terminal Function 1 Input –ve (Ch 1) 2 Input +ve (Ch 1) 4 Input –ve (Ch 2) 5 Input +ve (Ch 2) 6 To earth leakage detector 7 Output (Ch 1) 8 Output (Ch 1/Ch 2) 9 Output (Ch 2) 13 Supply –ve 14 Supply +ve EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Feb 2007 Product specifications are subject to change without notice EPS4514-2 MTL4514 SWITCH/ PROXIMITY DETECTOR INTERFACE single channel with line fault detection and phase reversal The MTL4514 enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection. SPECIFICATION See also common specification Number of channels One Location of switch Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location Location of proximity detector Zone 0, IIC, T4–6 if suitably certified Div.1, Group A, hazardous location Hazardous–area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Voltage applied to sensor 7 to 9V dc from 1k: ±10% Input/output characteristics Normal phase Outputs closed if input > 2.1mA (< 2k: in input circuit) Outputs open if input < 1.2mA (> 10k: in input circuit) Hysteresis: 200µA (650:) nominal Line fault detection (LFD) (when selected) User-selectable via switches on the side of the unit. Line faults are indicate
/
本文档为【MTL安全栅系列】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索