agilent66312A用户手册USER’SGUIDEDynamicMeasurementDCSourceAgilentModel66312ASystemDCPowerSupplyAgilent6611C,6612C,6613Cand6614Cs1AgilentPartNo.5962-8194MicroficheNo.5962-8195PrintedinMalaysia:March20042WarrantyInformationCERTIFICATIONAgilentTechnologiescertifiesthatthisproductmeti...
agilent66312A用户手册
USER’SGUIDEDynamicMeasurementDCSourceAgilentModel66312ASystemDCPowerSupplyAgilent6611C,6612C,6613Cand6614Cs1AgilentPartNo.5962-8194MicroficheNo.5962-8195PrintedinMalaysia:March20042WarrantyInformationCERTIFICATIONAgilentTechnologiescertifiesthatthisproductmetitspublishedspecificationsattimeofshipmentfromthefactory.AgilentTechnologiesfurthercertifiesthatitscalibrationmeasurementsaretraceabletotheUnitedStatesNationalBureauofStandards,totheextentallowedbytheBureau’scalibrationfacility,andtothecalibrationfacilitiesofotherInternationalStandardsOrganizationmembers.WARRANTYThisAgilentTechnologieshardwareproductiswarrantedagainstdefectsinmaterialandworkmanshipforaperiodwithahardwareproductandwhenproperlyinstalledonthathardwareproduct,arewarrantednottofailtoexecutetheirprogramminginstructionsduetodefectsinmaterialandworkmanshipforaperiodof90daysfromdateofdelivery.DuringthewarrantyperiodAgilentTechnologieswill,atitsoption,eitherrepairorreplaceproductswhichprovetobedefective.Agilentdoesnotwarrantthattheoperationforthesoftwarefirmware,orhardwareshallbeuninterruptedorerrorfree.Forwarrantyservice,withtheexceptionofwarrantyoptions,thisproductmustbereturnedtoaservicefacilitydesignatedbyAgilent.Customershallprepayshippingchargesby(andshallpayalldutyandtaxes)forproductsreturnedtoAgilentforwarrantyservice.ExceptforproductsreturnedtoCustomerfromanothercountry,AgilentshallpayforreturnofproductstoCustomer.WarrantyservicesoutsidethecountryofinitialpurchaseareincludedinAgilent’sproductprice,onlyifCustomerpaysAgilentinternationalprices(definedasdestinationlocalcurrencyprice,orU.S.orGenevaExportprice).IfAgilentisunable,withinareasonabletimetorepairorreplaceanyproducttoconditionaswarranted,theCustomershallbeentitledtoarefundofthepurchasepriceuponreturnoftheproducttoAgilent.LIMITATIONOFWARRANTYTheforegoingwarrantyshallnotapplytodefectsresultingfromimproperorinadequatemaintenancebytheCustomer,Customer-suppliedsoftwareorinterfacing,unauthorizedmodificationormisuse,operationoutsideoftheenvironmentalspecificationsfortheproduct,orimpropersitepreparationandmaintenance.NOOTHERWARRANTYISEXPRESSEDORIMPLIED.AGILENTSPECIFICALLYDISCLAIMSTHEIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE.EXCLUSIVEREMEDIESTHEREMEDIESPROVIDEDHEREINARETHECUSTOMER’SSOLEANDEXCLUSIVEREMEDIES.AGILENTSHALLNOTBELIABLEFORANYDIRECT,INDIRECT,SPECIAL,INCIDENTAL,ORCONSEQUENTIALDAMAGES,WHETHERBASEDONCONTRACT,TORT,ORANYOTHERLEGALTHEORY.ASSISTANCETheabovestatementsapplyonlytothestandardproductwarranty.Warrantyoptions,extendedsupportcontacts,productmaintenanceagreementsandcustomerassistanceagreementsarealsoavailable.ContactyournearestAgilentTechnologiesSalesandServiceofficeforfurtherinformationonAgilent’sfulllineofSupportPrograms.ofoneyearfromdateofdelivery.Agilentsoftwareandfirmwareproducts,whicharedesignatedbyAgilentforuse3SafetySummaryThefollowinggeneralsafetyprecautionsmustbeobservedduringallphasesofoperationofthisinstrument.Failuretocomplywiththeseprecautionsorwithspecificwarningselsewhereinthismanualviolatessafetystandardsofdesign,manufacture,andintendeduseoftheinstrument.AgilentTechnologiesassumesnoliabilityforthecustomer'sfailuretocomplywiththeserequirements.GENERALThisproductisaSafetyClass1instrument(providedwithaprotectiveearthterminal).Theprotectivefeaturesofthisproductmaybeimpairedifitisusedinamannernotspecifiedintheoperationinstructions.AnyLEDsusedinthisproductareClass1LEDsasperIEC825-1.ThisISMdevicecomplieswithCanadianICES-001.CetappareilISMestconformeàlanormeNMB-001duCanada.ENVIRONMENTALCONDITIONSThisinstrumentisintendedforindooruseinaninstallationcategoryII,pollutiondegree2environment.Itisdesignedtooperateatamaximumrelativehumidityof95%andataltitudesofupto2000meters.Refertothespecificationstablesfortheacmainsvoltagerequirementsandambientoperatingtemperaturerange.BEFOREAPPLYINGPOWERVerifythattheproductissettomatchtheavailablelinevoltage,thecorrectfuseisinstalled,andallsafetyprecautionsaretaken.Notetheinstrument'sexternalmarkingsdescribedunder"SafetySymbols".GROUNDTHEINSTRUMENTTominimizeshockhazard,theinstrumentchassisandcovermustbeconnectedtoanelectricalground.Theinstrumentmustbeconnectedtotheacpowermainsthroughagroundedpowercable,withthegroundwirefirmlyconnectedtoanelectricalground(safetyground)atthepoweroutlet.Anyinterruptionoftheprotective(grounding)conductorordisconnectionoftheprotectiveearthterminalwillcauseapotentialshockhazardthatcouldresultinpersonalinjury.ATTENTION:Uncircuitdeterrecontinuestessentielenvuedufonctionnementsécuritairedel'appareil.Nejamaismettrel'appareilenmarchelorsqueleconducteurdemise…laterreestd‚branch‚.FUSESOnlyfuseswiththerequiredratedcurrent,voltage,andspecifiedtype(normalblow,timedelay,etc.)shouldbeused.Donotuserepairedfusesorshort-circuitedfuseholders.Todosocouldcauseashockorfirehazard.DONOTOPERATEINANEXPLOSIVEATMOSPHEREDonotoperatetheinstrumentinthepresenceofflammablegasesorfumes.DONOTREMOVETHEINSTRUMENTCOVEROperatingpersonnelmustnotremoveinstrumentcovers.Componentreplacementandinternaladjustmentsmustbemadeonlybyqualifiedservicepersonnel.Instrumentsthatappeardamagedordefectiveshouldbemadeinoperativeandsecuredagainstunintendedoperationuntiltheycanberepairedbyqualifiedservicepersonnel.4SAFETYSYMBOLSDirectcurrentAlternatingcurrentBothdirectandalternatingcurrentThree-phasealternatingcurrentEarth(ground)terminalProtectiveearth(ground)terminalFrameorchassisterminalTerminalisatearthpotential.Usedformeasurementandcontrolcircuitsdesignedtobeoperatedwithoneterminalatearthpotential.TerminalforNeutralconductoronpermanentlyinstalledequipmentTerminalforLineconductoronpermanentlyinstalledequipmentOn(supply)Off(supply)Standby(supply).Unitswiththissymbolarenotcompletelydisconnectedfromacmainswhenthisswitchisoff.Tocompletelydisconnecttheunitfromacmains,eitherdisconnectthepowercordorhaveaqualifiedelectricianinstallanexternalswitch.Inpositionofabi-stablepushcontrolOutpositionofabi-stablepushcontrolCaution,riskofelectricshockCaution,hotsurfaceCaution(refertoaccompanyingdocuments)WARNINGTheWARNINGsigndenotesahazard.Itcallsattentiontoaprocedure,practice,orthelike,which,ifnotcorrectlyperformedoradheredto,couldresultinpersonalinjury.DonotproceedbeyondaWARNINGsignuntiltheindicatedconditionsarefullyunderstoodandmet.CautionTheCAUTIONsigndenotesahazard.Itcallsattentiontoanoperatingprocedure,orthelike,which,ifnotcorrectlyperformedoradheredto,couldresultindamagetoordestructionofpartoralloftheproduct.DonotproceedbeyondaCAUTIONsignuntiltheindicatedconditionsarefullyunderstoodandmet.5DECLARATIONOFCONFORMITYAccordingtoISO/IECGuide22andCEN/CENELECEN45014Manufacturer’sNameandAddressResponsiblePartyAlternateManufacturingSiteAgilentTechnologies,Inc.AgilentTechnologies(Malaysia)Sdn.Bhd550ClarkDrive,Suite101BuddLake,NewJersey07828USAMalaysiaManufacturingBayanLepasFreeIndustrialZone,PHIII11900Penang,MalaysiaDeclaresundersoleresponsibilitythattheproductasoriginallydeliveredProductNamesa)MobileCommunicationsDCSourceb)SystemDCPowerSupplyModelNumbersa)66332A,66312A,66311B,66311D66309B,66309D,66319B,66319D,66321B,66321Db)6631B,6632B,6633B,6634B6611C6612C,6613C,6614CProductOptionsThisdeclarationcoversalloptionsandcustomizedproductsbasedontheaboveproducts.ComplieswiththeessentialrequirementsoftheLowVoltageDirective73/23/EECandtheEMCDirective89/336/EEC(including93/68/EEC)andcarriestheCEMarkingaccordingly.EMCInformationISMGroup1ClassAEmissionsAsdetailedinElectromagneticCompatibility(EMC),CertificateofConformanceNumberCC/TCF/00/030basedonTechnicalConstructionFile(TCF)HPNJ8,datedApr.25,2000Assessedby:CelesticaLtd,AppointedCompetentBodyWestfieldsHouse,WestAvenueKidsgrove,Stoke-on-TrentStraffordshire,ST71TLUnitedKingdomSafetyInformationandConformstothefollowingsafetystandards.IEC61010-1:2001/EN61010-1:2001Canada:CSAC22.2No.1010.1:1992UL61010B-1:2003ThisDoCappliestoabove-listedproductsplacedontheEUmarketafter:January1,2004DateBillDarcy/RegulationsManagerForfurtherinformation,pleasecontactyourlocalAgilentTechnologiessalesoffice,agentordistributor,orAgilentTechnologiesDeutschlandGmbH,HerrenbergerStraβe130,D71034Böblingen,GermanyRevision:B.00.00IssueDate:Createdon11/24/20033:14PMDocumentNo.Eagle.11.24.docToobtainthelatestDeclarationofConformity,gotohttp://regulations.corporate.agilent.comandclickon“DeclarationsofConformity.”6AcousticNoiseInformationHerstellerbescheinigungDieseInformationstehtimZusammenhangmitdenAnforderungenderMaschinenläminformationsverordnungvom18Januar1991.*SchalldruckpegelLp<70dB(A)*AmArbeitsplatz*NormalerBetrieb*NachEN27779(Typprüfung).Manufacturer’sDeclarationThisstatementisprovidedtocomplywiththerequirementsoftheGermanSoundEmissionDirective,from18January1991.*SoundPressureLp<70dB(A)*AtOperatorPosition*NormalOperation*AccordingtoEN27779(TypeTest).PrintingHistoryTheeditionandcurrentrevisionofthismanualareindicatedbelow.Reprintsofthismanualcontainingminorcorrectionsandupdatesmayhavethesameprintingdate.Revisededitionsareidentifiedbyanewprintingdate.Arevisededitionincorporatesallneworcorrectedmaterialsincethepreviousprintingdate.Changestothemanualoccurringbetweenrevisionsarecoveredbychangesheetsshippedwiththemanual.Insomecases,themanualchangeappliesonlytospecificinstruments.Instructionsprovidedonthechangesheetwillindicateifaparticularchangeappliesonlytocertaininstruments.Thisdocumentcontainsproprietaryinformationprotectedbycopyright.Allrightsarereserved.Nopartofthisdocumentmaybephotocopied,reproduced,ortranslatedintoanotherlanguagewithoutthepriorconsentofAgilentTechnologies.Theinformationcontainedinthisdocumentissubjecttochangewithoutnotice.Copyright1997AgilentTechnologiesEdition1__________November,1997Update1__________July,1999Update2__________January,2000Update3__________March,20047TableofContentsWarrantyInformation2SafetySummary3DeclarationPage5AcousticNoiseInformation6PrintingHistory6TableofContents71-QUICKREFERENCE9Agilent66312ADynamicMeasurementDCSourceandAgilent6611C/6612C/6613C/6614CSystemDCPowerSupply9TheFrontPanel-AtaGlance10FrontPanelNumberEntry11FrontPanelAnnunciators12ImmediateActionKeys12FrontPanelMenus-AtaGlance13SCPIProgrammingCommands-AtaGlance14TheRearPanel-AtaGlance152-GENERALINFORMATION17DocumentOrientation17SafetyConsiderations18OptionsandAccessories18Description19Capabilities19FrontPanelControls19RemoteProgramming19OutputCharacteristic203-INSTALLATION21Inspection21Damage21PackagingMaterial21ItemsSupplied21Cleaning21Location22BenchOperation22RackMounting22InputConnections23ConnectthePowerCord23OutputConnections23WireConsiderations23CurrentRatings23VoltageDrops24MultipleLoadConnections24RemoteSenseConnections25SenseLeads25Stability26OVPConsiderations26INH/FLTConnections26ControllerConnections28GPIBInterface28RS-232Interface2984-TURN-ONCHECKOUT31Introduction31UsingtheKeypad31CheckoutProcedure32InCaseofTrouble34ErrorMessages34LineFuse345-FRONTPANELOPERATION35Introduction35FrontPanelDescription35SystemKeys37FunctionKeys38ImmediateActionKeys38ScrollingKeys38MeteringKeys39OutputControlKeys40EntryKeys41ExamplesofFrontPanelProgramming421-SettingtheOutputVoltageandCurrent422-QueryingandClearingOutputProtection433-MakingFrontPanelMeasurements434-ProgrammingtheDigitalOutputPort455-ProgrammingtheOutputRelay(option760only)466-SettingtheGPIBAddressandRS-232Parameters467-SavingandRecallingOperatingStates47A-SPECIFICATIONS49Specifications49SupplementalCharacteristics50B-VERIFICATIONANDCALIBRATION53Introduction53EquipmentRequired53TestSetup53PerformingtheVerificationTests54Turn-OnCheckout55VoltageProgrammingandMeasurementAccuracy55CurrentProgrammingandMeasurementAccuracy55PerformingtheCalibrationProcedure59FrontPanelCalibrationMenu59FrontPanelCalibration60CalibrationErrorMessages62ChangingtheCalibrationPassword62CalibrationOvertheGPIB63C-ERRORMESSAGES65ErrorNumberList65D-LINEVOLTAGECONVERSION69OpentheUnit69ConfigurethePowerTransformer69InstalltheCorrectLineFuse70ClosetheUnit70INDEX7191QuickReferenceAgilent66312ADynamicMeasurementDCSourceandAgilent6611C/6612C/6613C/6614CSystemDCPowerSupplyTheAgilent66312Aisa40Watt,highperformancedcpowersupplythatprovidesdynamicmeasurementandanalysisofvoltageandcurrentwaveforms.Itisdesignedtosimplifythetestingofdigitalcellularandmobilephones.Forexample,dataacquiredusingitsdynamicmeasurementcapabilitycanbeusedindeterminingthebatteryoperatingtimeofdigitalwirelesscommunicationsproducts.TheAgilent6611C,6612C,6613Cand6614Care40and50Watt,highperformancedcpowersupplieswithoutputcurrentmeasurementcapabilityinthemicroampererange.Theyarewellsuitedfortestingportablebattery-poweredproducts.Additionally,thecombinationofbench-topandsystemfeaturesinthesedcsourcesprovideversatilesolutionsforyourdesignandtestrequirements.Convenientbench-topfeatures♦Upto50Wattsoutputpower♦Easytouseknobforvoltageandcurrentsettings♦Highlyvisiblevacuum-fluorescentfrontpaneldisplay♦Excellentloadandlineregulation;lowrippleandnoise♦Measurementcapabilitydowntomicroamperelevels♦Currentsinkingupto30%oftheratedcurrent♦Instrumentstatestorage♦PortablecaseFlexiblesystemfeatures♦GPIB(IEEE-488)andRS-232interfacesarestandard♦SCPI(StandardCommandsforProgrammableInstruments)compatibility♦Triggeredacquisitionofdigitizedoutputcurrentandvoltagewaveforms(Agilent66312Aonly)♦I/Osetupeasilydonefromthefrontpanel1-QuickReference10TheFrontPanel-AtaGlancej14-characterdisplayshowsoutputmeasurementsandprogrammedvalues.kAnnunciatorsindicateoperatingmodesandstatusconditions.lRotarycontrolsetsvoltage,current,andmenuparameters.Useandtosettheresolution;thenadjustthevaluewiththeknob.mFrontpaneloutputconnectors.nTurnsthedcsourceonandoff.oSystemkeys:♦returntoLocalmode♦settheGPIBaddress♦settheRS-232interface♦displaySCPIerrorcodes♦saveandrecallinstrumentstates.pFunctionkeys:♦enable/disableoutput♦selectmeteringfunctions♦programvoltageandcurrent♦setandclearprotectionfunctions♦andscrollthroughthefrontpanelmenucommands.qEntrykeys:♦entervalues♦incrementordecrementvalues♦andselectfrontpanelmenuparameters.♦andselectadigitinthenumericentryfield.ÊÉÊÉË́ô66311A0-15V/0-3AMobileCommunicationsDCSourceLINEOffOnLocalAddressRecallMeterProtectVoltageCurrentOutputOutputOn/OffEnterNumberEnterCirEntryOVCalOCPProtCirSaveError1234567890.-50VDCMax+_+-SYSTEMFUNCTIONENTRYOUTPUTCVCCUnrDisOCPProtCalShiftRmtAddrErrSRQInputBackspace12345678QuickReference-111FrontPanelNumberEntryEnternumbersfromthefrontpanelusingoneofthefollowingmethods:UsethearrowkeysandknobtochangevoltageorcurrentsettingsNOTETheoutputmustbeONtoseethedisplayedvalueschangeinMetermode.UsetheFunctionkeysandknobtochangethedisplayedsettingsUsethearrowkeystoeditindividualdigitsinthedisplayedsettingIncrementstheflashingdigitDecrementstheflashingdigitMovestheflashingdigittotherightMovestheflashingdigittotheleftEntersthevaluewheneditingiscompleteUsetheFunctionkeysandEntrykeystoenteranewvalueNOTEIfyoumakeamistake,usetheBackspacekeytodeletethenumber,orpresstheMeterkeytoreturntometermode.1-QuickReference12FrontPanelAnnunciatorsCVTheoutputisoperatinginconstantvoltagemode.CCTheoutputisoperatinginconstantcurrentmode.UnrTheoutputisunregulated.DisTheoutputisOFF.PresstheOutputOn/Offkeytoturntheoutputon.OCPTheover-currentprotectionstateisON.PresstheOCPkeytoturnover-currentprotectionoff.ProtIndicatesthattheoutputhasbeendisabledbyoneoftheprotectionfeatures.PresstheProtClearkeytocleartheprotectioncondition.CalCalibrationmodeisON.ScrolltotheCalOffcommandandpresstheEnterkeytoexitthecalibrationmode.ShiftTheShiftkeyhasbeenpressed.RmtTheselectedRemoteprogramminginterface(eitherGPIBorRS-232)isactive.PresstheLocalkeytoreturntheunittofrontpanelcontrol.AddrTheinterfaceisaddressedtotalkorlisten.ErrThereisanerrorintheSCPIerrorqueue.PresstheErrorkeytoviewtheerrorcode.SRQTheinterfaceisrequestingservice.ImmediateActionKeysAtoggleswitchthatturnstheoutputofthedcsourceonoroff.Activatesfrontpanelcontrolwhentheunitisinremotemode(unlessaLockoutcommandisineffect).Resetstheprotectioncircuitandallowstheunittoreturntoitslastprogrammedstate.Atoggleswitchthatenablesordisablesovercurrentprotection.OutputOn/OffLocalProtClrShiftOCPShiftQuickReference-113FrontPanelMenus-AtaGlanceADDRESS7SetstheGPIBAddressINTFGPIBSelectsaninterface(GPIBorRS232)BAUDRATE300Selectsbaudrate(300,600,1200,2400,4800,9600)PARITYNONESelectsmessageparity(NONE,EVEN,ODD,MARK,SPACE)FLOWNONESelectsflowcontrol(XON-XOFF,RTS-CTS,DTR-DSR,NONE)LANGSCPISelectslanguage(SCPIorCOMP)*RCL0Recallsinstrumentstate*SAV0SavespresentinstrumentstateERROR0DisplayserrorsinSCPIerrorqueue12.000V0.204AMeasuresoutputvoltageandcurrent12.500VMAXMeasurespeakoutputvoltage11.000VMINMeasuresminimumoutputvoltage112.330VHIGHMeasuresthehighlevelofavoltagepulsewaveform10.080VLOWMeasuresthelowlevelofavoltagepulsewaveform112.000VRMSMeasuresrmsvoltage10.350AMAXMeasurespeakoutputcurrent10.050AMINMeasuresminimumoutputcurrent10.400AHIGHMeasuresthehighlevelofacurrentpulsewaveform10.012ALOWMeasuresthelowlevelofacurrentpulsewaveform10.210ARMSMeasuresrmscurrent1VOLT20.000SetstheoutputvoltageCURR2.000SetstheoutputcurrentOC--------Protectionstatus(exampleshowsovercurrenttripped)*RSTPlacesthedcsourceinthefactory-defaultstatePON:STATERSTSelectthepower-onstatecommand(RSTorRCL0)PROT:DLY0.08SetstheoutputprotectiondelayinsecondsRILATCHINGSetstheremoteinhibitmode(LATCHING,LIVE,orOFF)DFIOFFSetsthediscretefaultindicatorstate(ONorOFF)DFI:SOUROFFSelectstheDFIsource(QUES,OPER,ESB,RQS,orOFF)PORTRIDFISetstheoutputportfunctions(RIDFIorDIGIO)DIGIO7SetsandreadstheI/Oportvalue(0through7)RELAYONSetstheoutputrelaystate(ONorOFF)2RELAYNORMSetstheoutputrelaypolarity(NORMorREV)2VOLT:PROT22SetsovervoltageprotectionlevelCURR:RANGHIGHSetscurrentrange(HIGH,LOW,orAUTO)CURR:DETACDCSetscurrentmeasurementdetector(ACDCorDC)1CALONAccessescalibrationmenu(SeeUser’sGuide).Useandtoselectmenuparameters.Usetoexitanymenuandreturntometeringmode.1NotavailableonAgilent6611C–6614CorinCompatibilitymode.2NotavailableonAgilent66312A.AddressôôôôôRecallSaveShiftErrorShiftMeterôôôôôôôôôôVoltageCurrentProtectOutputôôôôôôôôôOVShiftShiftInputôCalShiftMeterËÌ1-QuickReference14SCPIProgrammingCommands-AtaGlanceNOTESome[optional]commandshavebeenomittedforclarity.RefertotheProgrammingGuideforacompletedescriptionofallprogrammingcommands.ABORtSENSeCALibrate:CURRent:RANGe<n>:CURRent[:SOURce][:POSitive]:DETectorACDC|DC1:MEASure:LOWRange:FUNCtion“VOLT”|“CURR”1:AC1:SWEep:OFFSet:POINts<n>1:DATA<n>:POINts<n>:LEVelP1|P2|P3|P4:TINTerval<n>:PASSword<n>:WINDowHANN|RECT:SAVE[SOURce:]:STATe<bool>[,<n>]CURRent[:LEVel][:IMMediate]<n>:VOLTage[:DC]:TRIGgered<n>:PROTection:PROTection:STATe<bool>DISPlayDIGital:DATA<n>[:STATe]<bool>:FUNCtionRIDF|DIG:MODENORMal|TEXTVOLTage[:LEVel][:IMMediate]<n>:TEXT<display_string>:TRIGgered<n>INITiate:PROTection<n>[:IMMediate]:SEQuence[1|21]STATus:NAMETRANsient|ACQuire1:PRESet:CONTinuous:SEQuence[1],<bool>:OPERation[:EVENt]?:NAMETRANsient,<bool>:CONDition?MEASure|FETCh2:ENABle<n>:ARRay:CURRent?1:NTRansition<n>:VOLTage?1:PTRansition<n>[:SCALar]:CURRent[:DC]?:QUEStionable[:EVENt]?:ACDC?1:CONDition?:HIGH?1:ENABle<n>:LOW?1:NTRansition<n>:MAX?1:PTRansition<n>:MIN?1SYSTem:VOLTage[:DC]?:ERRor?:ACDC?1:LANGuageSCPI|COMPatibility:HIGH?1:VERSion?:LOW?1:LOCal:MAX?1:REMote:MIN?1:RWLockOUTPutTRIGger[:STATe]<bool>[,NORelay]:SEQuence2|:ACQuire[:IMMediate]1:DFI[:STATe]<bool>:COUNt:CURRent<n>1:SOURceQUES|OPER|ESB|RQS|OFF:VOLTage<n>1:PON:STATeRST|RCL0:HYSTeresis:CURRent<n>1:PROTection:CLEar:VOLTage<n>1:DELay<n>:LEVel:CURRent<n>1:RELay[:STATe]<bool>3:VOLTage<n>1:POLarityNORM|REV3:SLOPe:CURRentPOS|NEG|EITH1:RI:MODELATCHing
/
本文档为【agilent66312A用户手册】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索