01循环水泵调试试验记录表TSC-01Saudi Rabigh 2×660MW UNIT 1(660MW) SCS COMMISSIONING RECORD NO:TSC-01 CODE:YD.Rabigh.TS.RK /JL/FB/TSC01 工程名称 NAME 沙特Rabigh 2×660MW #1机 Saudi Rabigh 2×660MW UNIT 1 试运阶段 PHASE 分部试运 TRIAL-R...
01循环水泵调试试验记录表TSC-01
Saudi Rabigh 2×660MW UNIT 1(660MW) SCS COMMISSIONING RECORD NO:TSC-01 CODE:YD.Rabigh.TS.RK /JL/FB/TSC01 工程名称 NAME 沙特Rabigh 2×660MW #1机 Saudi Rabigh 2×660MW UNIT 1 试运阶段 PHASE 分部试运 TRIAL-RUN 专业名称 PROFESSION 热控专业 I&C 项目名称 NAME 循环水系统试验纪录表 CW SYSTEM TEST RECORD NO. COMMISSIONING CONTENT RESULT REMARK 1 循环水泵 #1 CIRC WATER #1 PUMP YD.Rabigh.TS.RK /JL/FB/TSC01-001 2 循环水泵 #2 CIRC WATER #2 PUMP YD.Rabigh.TS.RK /JL/FB/TSC01-002 3 #1循环水泵顺控启停 #1 SEAW Pump SEQ Start / Stop YD.Rabigh.TS.RK /JL/FB/TSC01-003 4 #2循环水泵顺控启停 #2 SEAW Pump SEQ Start / Stop YD.Rabigh.TS.RK /JL/FB/TSC01-004 5 #1冷却水泵 #1 COLLING WATER PUMP YD.Rabigh.TS.RK /JL/FB/TSC01-005 6 #2冷却水泵 #2 COLLING WATER PUMP YD.Rabigh.TS.RK /JL/FB/TSC01-006 7 #3冷却水泵 #3 COLLING WATER PUMP YD.Rabigh.TS.RK /JL/FB/TSC01-007 施工部门: 调试部门: 运行部门: SEPCOⅢ: COMMISSIONING: OPERATION: SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:CIRC WATER #1 PUMP CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-001 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 START PERMIT (AND) a、循环水泵轴承温度正常<90 a、#1 Sea Water Intake Pump Bearing Temp<90 b、循环水泵电机轴承温度正常<80 b、#1 Sea Water Intake Pump Motor Bearing Temp<80 c、循环水泵电机绕组温度正常<130 c、#1 Sea Water Intake Pump Motor Wind Temp <130 d、#1循环水泵前池水位>5000mm d、#1 Sea Water Intake Pump Level >5000mm e、旋转滤网水位差不大(<300mm) e、Travel Screen Diff Level NOT H(<300mm) f、无反转信号 f、No Reverse Signal g、凝汽器A侧或B侧水路畅通(凝汽器进出口门全开) g、Water sideA or B of Condenser open h、1m内无泵停止且2m内无泵启动,但备用泵跳闸联锁启动除外 h、No Pump stop in 60s and No Pump start in 120s ,Except backup Pump trip and interlock start i、任一滤网冲洗水泵运行,或其他循泵运行 i、Any Travel Screen Flush Pump running OR other SEAWP running j、冷却水流量不低 j、cooling water flow not L 2 STOP PERMIT TRUE 3 INTERLOCK START (OR) a、联锁投入,一台泵运行,跳闸,先程控关跳闸泵,再立即启备用程控; a、One pump running and trip, SEQ stop it first and start standby one immediately b、联锁投入,两台泵运行,跳闸,先程控关跳闸泵,延时1m启备用程控。 b、Two Pumps running and one trip, SEQ stop it first and delay 2min then start standby one 4 INTERLOCK STOP (OR) a、循环水泵轴承温度>100 延时2秒 a、#1 Sea Water Intake Pump Bearing Temp>100, delay 2s b、循环水泵电机轴承温度>85, 延时2秒 b、#1 Sea Water Intake Pump Motor Bearing Temp>85,delay 2s c、循环水泵电机绕组温度>140, 延时2秒 c、#1 Sea Water Intake Pump Motor Wind Temp>140,delay 2s d、循环水泵运行延时15s,出口液控蝶阀关 d、#1 Sea Water Intake Pump running delay 15s, Outlet Hydraulic Butterfly Valve Closed SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:CIRC WATER #2 PUMP CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-002 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 START PERMIT (AND) a、循环水泵轴承温度正常<90 a、#2 Sea Water Intake Pump Bearing Temp<90 b、循环水泵电机轴承温度正常<80 b、#2 Sea Water Intake Pump Motor Bearing Temp<80 c、循环水泵电机绕组温度正常<130 c、#2 Sea Water Intake Pump Motor Wind Temp <130 d、#2循环水泵前池水位>5000mm d、#2 Sea Water Intake Pump Level >5000mm e、旋转滤网水位差不大(<300mm) e、Travel Screen Diff Level NOT H(<300mm) f、无反转信号 f、No Reverse Signal g、凝汽器A侧或B侧水路畅通(凝汽器进出口门全开) g、Water sideA or B of Condenser open h、1m内无泵停止且2m内无泵启动,但备用泵跳闸联锁启动除外 h、No Pump stop in 60s and No Pump start in 120s ,Except backup Pump trip and interlock start i、任一滤网冲洗水泵运行,或其他循泵运行 i、Any Travel Screen Flush Pump running OR other SEAWP running j、冷却水流量不低 j、cooling water flow not L 2 STOP PERMIT TRUE 3 INTERLOCK START (OR) a、联锁投入,一台泵运行,跳闸,先程控关跳闸泵,再立即启备用程控; a、One pump running and trip, SEQ stop it first and start standby one immediately b、联锁投入,两台泵运行,跳闸,先程控关跳闸泵,延时1m启备用程控。 b、Two Pumps running and one trip, SEQ stop it first and delay 2min then start standby one 4 INTERLOCK STOP (OR) a、循环水泵轴承温度>100,延时2秒 a、#2 Sea Water Intake Pump Bearing Temp>100, delay 2s b、循环水泵电机轴承温度>85, 延时2秒 b、#2 Sea Water Intake Pump Motor Bearing Temp>85, delay 2s c、循环水泵电机绕组温度>140,延时2秒 c、#2 Sea Water Intake Pump Motor Wind Temp>140, delay 2s d、循环水泵运行延时15s,出口液控蝶阀关 d、#2 Sea Water Intake Pump running delay 15s, Outlet Hydraulic Butterfly Valve Closed SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:#1 SEAW Pump SEQ Start CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-003 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 SEQ START PERMIT a、循环水泵轴承温度正常<90 a、#1 Sea Water Intake Pump Bearing Temp<90 b、循环水泵电机轴承温度正常<80 b、#1 Sea Water Intake Pump Motor Bearing Temp<80 c、循环水泵电机绕组温度正常<130 c、#1 Sea Water Intake Pump Motor Wind Temp <130 d、#1循环水泵前池水位>5000mm d、#1 Sea Water Intake Pump Level >5000mm e、旋转滤网水位差不大(<300mm) e、Travel Screen Diff Level NOT H(<300mm) f、无反转信号 f、No Reverse Signal g、凝汽器A侧或B侧水路畅通(凝汽器进出口门全开) g、Water sideA or B of Condenser open h、1m内无泵停止且2m内无泵启动,但备用泵跳闸联锁启动除外 h、No Pump stop in 60s and No Pump start in 120s ,Except backup Pump trip and interlock start 2 SEQ STOP PERMIT a、2m内无泵停止且1m内无泵启动 a、No Pump stop in 120s and No Pump start in 60s. 3 HAPPEN CONDITION a、联锁投入,联锁泵跳闸 a、PUMP INTERLOCK PUTIN ,PUMP TRIP 4 SEQ START (STEP) a、在#2和#3循环水泵没运行情况下,如果没有滤网冲洗水泵运行,则启动选中的(#1或#2)滤网冲洗水泵 a、Start #1 or #2 Travel Screen Flush Pump b、开出口碟阀2秒 b、Open Outlet Hydraulic BTV 2s c、启动#1循环水泵,15s内开出口碟阀到15度 c、Start SEAW Pump, open Outlet Hydraulic Butterfly Valve to 15°in 15s d、全开出口碟阀 d、Full open Outlet Hydraulic Butterfly Valve in 30s e、如果没有冷却水泵运行,则启动#1号冷却水泵 e、Start Cooling Pump 5 SEQ STOP (STEP) a、5s内关出口碟阀到15度 a、Close Outlet Hydraulic BTV to 15° b、停止#1循环水泵 b、Stop #1 SEAW Pump c、15s内全关出口碟阀 c、Close Outlet Hydraulic BTV in 15s SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:#2 SEAW Pump SEQ Start CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-005 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 SEQ START PERMIT a、循环水泵轴承温度正常<90 a、#2 Sea Water Intake Pump Bearing Temp<90 b、循环水泵电机轴承温度正常<80 b、#2 Sea Water Intake Pump Motor Bearing Temp<80 c、循环水泵电机绕组温度正常<130 c、#2 Sea Water Intake Pump Motor Wind Temp <130 d、#2循环水泵前池水位>5000mm d、#2 Sea Water Intake Pump Level >5000mm e、旋转滤网水位差不大(<300mm) e、Travel Screen Diff Level NOT H(<300mm) f、无反转信号 f、No Reverse Signal g、凝汽器A侧或B侧水路畅通(凝汽器进出口门全开) g、Water sideA or B of Condenser open h、1m内无泵停止且2m内无泵启动,但备用泵跳闸联锁启动除外 h、No Pump stop in 60s and No Pump start in 120s ,Except backup Pump trip and interlock start 2 SEQ STOP PERMIT a、2m内无泵停止且1m内无泵启动 a、No Pump stop in 120s and No Pump start in 60s. 3 HAPPEN CONDITION a、联锁投入,联锁泵跳闸 a、PUMP INTERLOCK PUTIN ,PUMP TRIP 4 SEQ START (STEP) a、在#1和#3循环水泵没运行情况下,如果没有滤网冲洗水泵运行,则启动选中的(#1或#2)滤网冲洗水泵 a、Start #1 or #2 Travel Screen Flush Pump b、开出口碟阀2秒 b、Open Outlet Hydraulic BTV 2s c、启动#2循环水泵,15s内开出口碟阀到15度 c、Start SEAW Pump, open Outlet Hydraulic Butterfly Valve to 15°in 15s d、全开出口碟阀 d、Full open Outlet Hydraulic Butterfly Valve in 30s e、如果没有冷却水泵运行,则启动#1号冷却水泵 e、Start Cooling Pump 5 SEQ STOP (STEP) a、5s内关出口碟阀到15度 a、Close Outlet Hydraulic BTV to 15° b、停止#2循环水泵 b、Stop #2 SEAW Pump c、15s内全关出口碟阀 c、Close Outlet Hydraulic BTV in 15s SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:#1 cooling water pump CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-005 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 START PERMIT (AND) TRUE 2 STOP PERMIT TRUE 3 INTERLOCK START (OR) 连锁投入,运行泵跳闸 Interlock put on ,the running pump trip 4 INTERLOCK STOP (OR) SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:#2 cooling water pump CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-006 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 START PERMIT (AND) TRUE 2 STOP PERMIT TRUE 3 INTERLOCK START (OR) 连锁投入,运行泵跳闸 Interlock put on ,the running pump trip 4 INTERLOCK STOP (OR) SCS循环水系统试验记录表 CW SYSTEM TEST RECORD NAME:#3 cooling water pump CODE:YD.Rabigh.TS.RK /JL/FB/TSC01-007 NO. CONTENT RESULT REMARK TEST CONDITION a、运行人员对相关系统检查完成并正常 a、Operators have finished systems checking and the systmes is in normal operation b、DCS相关硬件、软件工作正常 b、DCS handwares and software are in normal operation 1 START PERMIT (AND) TRUE 2 STOP PERMIT TRUE 3 INTERLOCK START (OR) 连锁投入,运行泵跳闸 Interlock put on ,the running pump trip 4 INTERLOCK STOP (OR) 12
/
本文档为【01循环水泵调试试验记录表TSC-01】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索