Zhejiang Fluma Instrument Co., Ltd.---------Products List
Zhejiang Fluma Instrument Co. Ltd. was found in 1987, developing, manufacturing and selling flow meters, flow standard
calibrator and automatic control systems. Fluma is able to manufacture 20000 sets of flow meters a year, having strong
technical force, advanced manufacturing process, strict inspection procedure, scientific management system and precise
equipments for production and testing.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
LUY PRECESSION VORTEX
FLOWMETER
DN 20 ~200
Accuracy Class: 1.0 and 1.5
PN 1.6, 2.5, 4.0 and 6.3MPa
Temperature:-20 ~+70℃
It is used to measure gas flow rate in
the fields of petroleum, chemical
industry, power plant, metallurgy,
city gas and so on.
FLLQ GAS ROOTS
FLOWMETER
DN 25 ~100
Accuracy Class: 1.0 and 1.5
PN 1.6MPa
Temperature:-25 ~+55℃
It is used to measure flow rate of
natural gas, city gas, propane,
nitrogen and industrial inert gas.
It is used for measurement of
non-corrosive gases such as natural gas,
FLWQ GAS TURBINE METERS
DN 25 ~400
Accuracy Class: 1.0 and 1.5
PN 1.6, 2.5, and 4.0 MPa
Temperature:-20 ~+70℃
It is used to measure flow rate of natural
gas, city gas, propane and nitrogen in
the fields of petroleum, chemical
industry, metallurgy, and so on.
.
FLJY PRECISE OIL
FLOW METER
DN 25 ~100
Accuracy Class: 0.1, 0.2 and 0.5
Viscosity:0.6~50mPa.s
Temperature:-20 ~+100℃
It is used for metering or trading
in the field of gasoline, kerosene,
diesel and so on.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
FKV EMERGENCY
SHUT-DOWN VALVE
DN 40 ~80
PN 25 MPa
Temperature:-40 ~+85℃
Lower limit: 0.1~3 MPa
Upper limit: 3~9.5 MPa
It is used to shut off valve when
pressure of pipe is less than or more
than the setting pressure..
LUB VORTEX
FLOWMETER
DN 10 ~300
Accuracy Class: 1.0 and 1.5
PN 1.6 ~ 42MPa
Temperature:-35 ~+130℃
It is used to measure flow rate in
the fields of petroleum, chemical
industry, power plant, and so on,
especially oil field affusion.
FLD ELECTROMAGNETIC
FLOW METER
DN 10 ~2200
Accuracy: ±0.5 % ~ ±2.5 %
PN 0.6~ 26 MPa
Temperature:-20 ~+80℃
It is used to measure flow rate of
conducting fluid and slurry in the
fields of petroleum chemical, water,
mining, metallurgy, food, medicine
and so on.
FLCK FLOW
AUTO-CONTROLLER
DN 25 ~50
Accuracy Class: 1.0 and 1.5
PN 4, 16, 25 and 32MPa
Temperature: Less than90℃
It is used to control and adjust
flow rate in the fields of
petroleum, chemical industry,
metallurgy, food, medicine
and so on.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
Calibrating Device by Means of Critical Flow Venture Nozzles
That is a kind of standard calibrator. It is used to calibrate positive
displacement flow meters and velocity flow meters.
Pipe diameter for testing: DN15~DN400
Uncertainty of device: Urel<0.25% k=2;
Maximum flow rate Qmax: 7000m3/h
Minimum flow rate Qmin: 1m3/h
FYT DIGITAL
PRESSURE
TRANSMITTER
Pressure range:0 ~ 60 MPa
Accuracy:±0.1 %~±1.0 %FS
Temperature:-40 ~+85℃
It is used to measure pressure
of flow in the fields of
petroleum, chemical industry,
natural gas and oil field and so
on.
FYB DIGITAL
PRESSURE GAUGE
Pressure range:0 ~ 60 MPa
Accuracy:±0.1 %~±1.0 %FS
Temperature:-40 ~+85℃
It is used to measure pressure of
flow in the fields of petroleum,
chemical industry, natural gas
and oil field and so on.
Pipe Prover for Calibrating Positive Displacement
Meters
That is a kind of calibrator.
It can be used to calibrate flow meters.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
Contact: Jane
Direct Tel: Cell:15058910148 Fax: 0577-85983200
Postcodes(邮编): 325024
E-mail: iamtomorrow@126.com
Website:www.fuma-cn.com
Company(公司): ZHEJIANG FLUMA INSTRUMENT CO.,LTD.浙江富马仪表有限公
司
Address(地址): Yongqiang High-new Tech.Industry district. Wenzhou,Zhejiang,China
(浙江温州永强高新技术产业园区)
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn