GE德鲁克(Druck) PTX 120 WL 湿湿差压传感器 P TX 12 0 / W L P T X 1 2 0 / W L Wet/Wet Differential Pressure Transmitter ! ±0.1% B.S.L. for ranges to 500 psi ! Encapsulated electronics !! Zero and span trim controls !! Intrinsically safe as standard ! ±1.5% total error band -20° to +80°C ! Two wire,...
GE德鲁克(Druck) PTX 120 WL 湿湿差压传感器
P TX 12 0 / W L P T X 1 2 0 / W L Wet/Wet Differential Pressure Transmitter ! ±0.1% B.S.L. for ranges to 500 psi ! Encapsulated electronics !! Zero and span trim controls !! Intrinsically safe as standard ! ±1.5% total error band -20° to +80°C ! Two wire, 4-20mA The PTX 120/WL is a truly “wet/wet” differential pressure transmitter of accepting a wide variety of pressure media on each port. The positive (high pressure) port is a fully welded 316 stainless steel assembly, the negative (low pressure) port contains stainless steel, silicon, glass, epoxy, aluminum and a silicon ‘o’ ring seal. The two pressure ports act upon a piezoresistive bridge diffused into a silicon diaphragm, which provides high overload capabilities together with excellent linearity, hysteresis performance and fast response. Integral two-wire electronics provide excitation and conditioning of the bridge signal to generate a 4-20mA output including fine trim potentiometers for zero and span adjustment. A fully welded case assembly is completed with an integral cable or a mounting block which includes a plug and socket electrical connector. Many options are available including units with dual isolating diaphragms to provide metallic media compatibility on both ports, fully submersible units, and hermetic designs incorporating a welded plug and socket electrical connector. P T X 1 2 0 / W L Wet/Wet Differential Pressure Transmitter Druck Incorporated 4 Dunham Drive New Fairfield , CT 06812 Tel: (203) 746-0400 Fax: (203) 746-2494 E-Mail: usa.sales@druck.com www.druck.com www.pressure.com Representative PDS-A094 5/02 SSTTAANNDDAARRDD SSPPEECCIIFFIICCAATTIIOONN OOppeerraattiinngg PPrreessssuurree RRaannggeess 2.5, 5, 10, 15, 20, 30, 50, 75, 100, 150, 200, 300 and 500 psi differential. Other pressure units can be specified. MMaaxxiimmuumm LLiinnee PPrreessssuurree ((CCaassee PPrreessssuurree)) 30 psi - PTX 120/2WL 100 psi - PTX 120/WL 500 psi - PTX 120/35WL 1000 psi available on request. OOvveerrpprreessssuurree The rated pressure can be exceeded by the following multiples causing negligible calibration change: Positive side: 10x for 2.5 psi range 6x for 5 psi range 4x for 10 to 300 psi range 500 psi range maximum pressure 1500 psi. Negative side: 6x for 2.5 psi range 4x for 5 psi range 1.5x for 100 psi range For bi-directional use please refer to manufacturer. PPoossiittiivvee PPrreessssuurree MMeeddiiaa Fluids compatible with 316 stainless steel. NNeeggaattiivvee PPrreessssuurree MMeeddiiaa Fluids compatible with 316 stainless steel and quartz. TTrraannssdduuccttiioonn PPrriinncciippllee Integrated silicon strain gauge bridge. CCoommbbiinneedd NNoonn--LLiinneeaarriittyy aanndd HHyysstteerreessiiss ±1% B.S.L. each side considered separately. ±0.06% B.S.L available for ranges to 300 psi on request. Please refer to manufacturer. Transmitters are calibrated in the positive direction only unless specified. TTrraannssmmiitttteerr SSuuppppllyy VVoollttaaggee 9-30V d.c This voltage must appear across the transmitter terminals. For other supply voltages please refer to manufacturer. SSuuppppllyy SSeennssiittiivviittyy 0.005% F.S.O./Volt and excellent 50Hz and 100Hz supply ripple rejection. OOuuttppuutt CCuurrrreenntt 4mA at zero pressure. 20mA at full range pressure. Zero suppression can be incorporated to allow for bi-directional use, and for example to give 4mA at 20% of full range pressure. RReessoolluuttiioonn Infinite. SSiiddee ttoo SSiiddee EErrrroorr ((CChhaannggee ooff ssllooppee)) 0.5% approximately. ZZeerroo ooffffsseett ±5% F.S.O., sealed potentiometer adjustment. SSppaann SSeettttiinngg ±5% F.S.O., sealed potentiometer adjustment. OOppeerraattiinngg TTeemmppeerraattuurree RRaannggeess -20° to +80°C standard. This temperature ranges can be extended. TTeemmppeerraattuurree EEffffeeccttss ±0.5% total error band 0° to 50° C ±1.5% total error band -20° to +80° C 2.5 psi range 0.5% total error band 10° to 40° C For special applications it is possible to give improved temperature compensation over a wider range. AAcccceelleerraattiioonn SSeennssiittiivviittyy 0.044% F.S.O./g for 5.07 psi decreasing to 0.0005% F.S.O./g for 307.5 psi. MMeecchhaanniiccaall SShhoocckk 1000g for 1msec in each of three mutually perpendicular axes will not affect calibration. WWeeiigghhtt 10.6 oz. nominal. EElleeccttrriiccaall CCoonnnneeccttiioonn 3 ft. integral cable supplied. Longer lengths available on request. IInnttrriinnssiicc SSaaffeettyy This transmitter is certified for use with barrier systems to EEx ia gas group IIC with a T4 rating at an ambient temperature of 80° C to BS 5501 part 7 and Cenelec EN50 020. OOTIIOONNSS Integral connector PTX 120/WL/C (see installation below). Mating socket Amphenol-type 62GB-16F10-6S or equivalent (100° C) supplied as standard with integral connector version. OORRDDEERRIINNGG IINNFFOORRMMAATTIIOONN Please state the following: (1) Type number ee..gg.. PPTTXX 112200//22WWLL (2) Differential Pressure Range (3) Maximum Line Pressure (4) Temperature range (5) Pressure connection (6) Pressure media For non-standard requirements please specify in detail. IINNSSTTAALLLLAATTIIOONN DDRRAAWWIINNGGSS:: Dimensions in inches TO TA L LO A D R ES IS TA N C E (O H M S ) POWER SUPPLY VOLTAGE (V.d.c.) 1500 1000 500 0 10 20 30 40 PTX 120/WL PTX 120/W/L/C Continuing development sometimes necessitates specification changes without notice. Druck is an ISO 9001 registered company.
/
本文档为【GE德鲁克(Druck) PTX 120 WL 湿湿差压传感器】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索