7.5Fr球囊穿刺步骤 FOR SHEATHLESS INSERTION FOR SHEATHED INSERTION PRESSURE MONITORING SET UP The angle of insertion should be 45˚ or less. Make a small incision at the exit of the guidewire. Insert the vessel dilator over the guidewire, tapered end first. Push then twist to...
7.5Fr球囊穿刺步骤
FOR SHEATHLESS INSERTION FOR SHEATHED INSERTION PRESSURE MONITORING SET UP The angle of insertion should be 45˚ or less. Make a small incision at the exit of the guidewire. Insert the vessel dilator over the guidewire, tapered end first. Push then twist to firmly attach the one-way valve to the male luer fitting of the IAB catheter. Using the provided 30cc syringe apply a 30cc vacuum. Twist and remove the syringe, keeping the one-way valve attached to the male luer fitting of the IAB catheter. Carefully spread the subcutaneous tissue to facilitate sheathless insertion. Remove the IAB catheter from the T-handle by pulling STRAIGHT out to avoid damaging it. Advance the IAB catheter over the guidewire into the artery in short strokes until correct placement is achieved. Advance the sheath seal as close to the insertion site as possible and secure the IAB catheter to the patient’s leg. Insert the introducer dilator into the sheath hub and secure. Advance the sheath over the guidewire into the artery using a rotary motion. Withdraw the introducer dilator leaving the sheath in place. Remove the IAB catheter from the T-handle by pulling STRAIGHT out to avoid damaging it. Advance the IAB catheter in short strokes through the sheath into the artery until correct placement is achieved. Push the sheath seal into the hub of the sheath and secure the IAB catheter to the patient’s leg. Remove the guidewire and aspirate 3cc of blood from the inner lumen. Perform a manual flush of the inner lumen with 3-5cc of flush solution. Attach a standard arterial fluid pressure monitoring apparatus. Twist and pull to remove the one-way valve from the IAB catheter. Connect the IAB catheter’s male luer fitting to the female luer fitting of the catheter extender. Connect the male luer fitting of the catheter extender to the safety disk of the Intra-aortic Balloon Pump. INSERTION OF THE INTRA-AORTIC BALLOON CATHETER ABBREVIATED GUIDE FOR LINEAR 7.5Fr. AND MEGA 8Fr. IAB CATHETER INSERTION This guide is a reference for personnel trained in using MAQUET IAB Catheters. Do not use this guide until after thoroughly reading the Instructions For Use provided. Note: This information is to be used as a guidance only. Clinical information and patient factors such as torso length should be considered when selecting the appropriate balloon size. 1 PREPARING THE IAB CATHETER CONNECTION TO IABP INTRA-AORTIC BALLOON SIZING GUIDE 2 3 4 5 6 7 8 9 10 107 8 9 11 12 13 14 15 16 6' 5' 4' Approx. ht: < 5'0" (< 152cm) Approx. ht: 5'0" to 5'4" (152cm - 162cm) Approx. ht: 5'4" to 6'0" (162cm - 183cm) Approx. ht: ≥ 5'4" (≥ 162cm) 25cc 34cc 40cc 50cc ® MAQUET Registered Trademark of MAQUET GmbH & Co. KG · Reg. QUG: MCV-PT-80000308-EN-01 · PN: 0002-08-1002 R0 · Copyright 2010 MAQUET Cardiovascular LLC or its affiliates · Subject to modifications due to technical development. 3.10. Caution: U.S. Federal Law restricts this device to sale by or on the order of a physician. Refer to Instructions for Use for current indications, warnings, contraindications, and precautions. DATASCOPE IS NOW MAQUET CARDIOVASCULAR Datascope Cardiac Assist 15 Law Drive Fairfield, NJ 07004 Phone: +1 973 244 6100 Please visit our website: www.datascope.com www.maquet.com
/
本文档为【7.5Fr球囊穿刺步骤】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索