初级建筑构物消防员技能考试考点初级建筑构物消防员技能考试考点 Skills examination center Fire extinguisher test center on the first floor First, portable fire extinguishers using test sites (4 people a group) In the 5 meters away from the fire place, ABC will fire on the shaker (must be), after removing the ...
初级建筑构物消防员技能考试考点
初级建筑构物消防员技能考试考点 Skills examination center Fire extinguisher test center on the first floor First, portable fire extinguishers using test sites (4 people a group) In the 5 meters away from the fire place, ABC will fire on the shaker (must be), after removing the seals, the bolt will fire nozzle at the roots left to right. Two, C fire extinguishers Inspection Center (oral) 1 、 is there a certificate of quality? (if yes, in the retention period) 2 、 is the cylinder and bottom rusty? 3 、 is the nozzle clear? 4, the pressure is enough? Or is there pressure? 5, if there is a seal? 6. Is there a bolt? 7, not all parts (without bolt or seals can be added to this) Two floor automatic alarm, fire control room, examination center One question: correctly identify fire control equipment (fire alarm, fire telephone host, fire emergency broadcast, CRT, fire control linkage controller) 1, alarm control part Upper part: fire alarm (window, printer) Central: fire telephone host Bottom: fire emergency broadcast 2, CRT (fire controller graphic display device) 3 、 fire linkage controller The two question: fire alarm controller switch sequence, self check, mute, reset function key use 1, fire alarm switch machine order (dictation) First open the main power supply (city power), and then open the standby power supply (UPS), and finally open the controller switch. Turn off. 2 、 the operation and function of self checking key Operate: Turn key - enter password: 1234 - press right shift key - select system debugging - use move down key - select sound and light test - press confirm key, then complete self check. Function: check whether the function of alarm controller is normal or not 3. Operation and function of silencing key: Operation: direct pressure Effects: silence, re sound 4. The function and function of reset key Operation: direct pressure Role: make the fire alarm return to normal and monitor the working state The three question: check the fire alarm controller main standby power supply working state 1 、 identification of main standby power supply working state When the main and standby power supply is working properly, the color of the light is "green"" 2, main power failure inspection and restoration Three cases of main power failure: One is the blackout of the urban power grid. (restore method: wait for incoming telegram. Abbreviation "wait" The two kind is: the power switch is in bad contact. (restore method: fix. Referred to as "repair" The three kind is: the insurance burns out. (restore method: replace. Short for "change" Three cases of standby power failure One is that the voltage is too low. (recovery method: charging. Abbreviation "filling") The two is: poor contact switch. (restore method: fix. Referred to as "repair" The three kind is: the insurance burns out. (restore method: replace. Short for "change" The four question: oral "fire control room on duty records" and "handover class records" content? 1, fire control room duty records should be registered content First, the alarm type. Two is the alarm site. Three is the cause of the alarm. Four is the alarm time. Five is the processing method. 2, the specific requirements are: complete duty time; duty officer name; and shall not use pencil, pen or pen to fill in, only carbon ink) Five question: correctly deal with fire alarm and false positives 1. Distinguish fire and fault signals. If the fire alarm - fire control alarm light is "red"". If it is yellow, the alarm controller is out of order. 2, the restoration of false positives: press the mute button directly, you can eliminate false positives. 3, check the alarm using information method One is through the window inquiry; two is through the printer; the three is through the CRT query. Six question: dictate how to make a "119" call accurately The first step is to dial "119". The second step is to confirm whether it is "119"" The third step is to report the fire detailed address and fire place to the fire fighter. The fourth step is to alert the firemen about the nature of the fire and the fire and whether anyone is trapped. The fifth step is to leave your name and telephone number The sixth step is to meet the firemen at the junction. The seven question: manual alarm equipment identification and maintenance 1, the type of equipment reported: one is not recoverable; one is recoverable type (training centers are recoverable) 2, maintenance. (blow in and out), that is, blow and blow the dust, rub it with a less wet towel - rub it off when it is wet and rub it after it dries 3. The recovery method of recoverable hand newspaper equipment: use special tools Four floor fire sprinkler system test site Topic: identifying nozzle types 1 、 identification installation type: Pendant (sprinkler appearance like petals), upright (sprinkler appearance like beer bottle cap), side wall type 2 、 identifying types of work: open type and closed type? 3. Identify the type of sprinkler system installed on the four floor. (from the right side: rain system, wet system, wet and dry system, pre acting system, water curtain system, foam system) 4, identify the end of the water test device and role (1) composition: pipeline, pressure gauge, drain valve (2) function: check the flow indicator, pressure switch, alarm valve, hydraulic alarm action is normal; whether the water distribution pipe is smooth; the most unfavorable point of the sprinkler working pressure. (3) test method of water test device at the end: Open end testing equipment, water pressure should be greater than or equal to 0.05Mpa. The flow indicator, alarm valve and pressure switch shall act. The fire pump should be started automatically within 5 minutes after the end of the water test device is opened. 3. Identify quick, standard, and special response nozzles (glass balls, small or small, for fast, Glass balls are rough or big as standard 4. The action temperature and color mark of the oral sprinkler Orange 57 Red 68 Yellow 79 Green 93 Blue 141 On the eighth floor of the fire door test centers One, one step down the test site (dictation) See if the panel is in good condition; Two see the lifting button panel can normal shutter doors or rose to the top down in the end; Three is to let the remote control whether the shutter can drop in the end; Four is to smoke alarm, see whether the rolling door can drop in the end. Two, two steps down the test site (dictation) Is there a mess at the bottom of the door?; The two is to see whether the top roller shutter door; The three is to see if the panel is energized; The four is to see if the manual zipper can be pulled; Five is to see whether the smoke sense of normal work. Three, fire door is divided into: normally open (with automatic release), often closed (with door closer, sequencer) Four, smoke valve: automatically open after the fire, when the temperature reached 280 degrees, automatically shut down. Five. Air supply valve: automatically open after fire, when the temperature reaches 70 degrees, automatic shutdown.
/
本文档为【初级建筑构物消防员技能考试考点】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索