SIWAREX_CS整定步骤,西门子公司发行 Page 1 of 15 Calibrating SIWAREX CS with SIWATOOL CS FAQ Release 1.0 Jan 2008 Keywords: SIWATOOL CS software, SIWAREX CS module,...
SIWAREX_CS整定步骤,西门子公司发行
Page 1 of 15 Calibrating SIWAREX CS with SIWATOOL CS FAQ Release 1.0 Jan 2008 Keywords: SIWATOOL CS software, SIWAREX CS module, zero, range, adjustment, calibration, commissioning Contains - Hardware requirements page 2-3 - Connections page 4-5 - SIWATOOL start page 6 - Resolution page 7 - Filters page 8 - Parameters page 9-10 - Calibration procedure page 11-13 - STEP 7 programming page 14 Page 2 of 15 Q: How is the SIWAREX CS calibrated with SIWATOOL CS? A: Following hardware parts and software are requested to build an ET200S station with a scale: SIWAREX CS module, Terminal module 30mm, IM151 Profibus or Profinet, Power Module, terminal module for power module, SIWATOOL CS configuration package, RS232 cable, computer with Windows XP or higher and a calibration weight bigger than 5% of the sum of the nominal value of all load cells. Requested parts: ET200S PowerModule SIWAREX CS Terminal module 30mm IM 151 With Terminal module 15mm 7MH4910-0AA01 6ES7193-4GC20-0AA0 SIWATOOL RS232 Cable: PROFIBUS or PROFINET 7MH4607-8CA connection Page 3 of 15 Configuration Package for SIWAREX CS: Adjustment weight Scale The physical connection is as shown below: Page 4 of 15 Page 5 of 15 Connection terminal of the sensor RS232 interface 24V Power suply Ground terminal Page 6 of 15 Start SIWATOOL CS. Select COM1 as the communication interface. Click Online. Page 7 of 15 Resolution of SIWAREX CS The weight is converted into a 16 bits value. The value is comprised between 0 and 64000 The value is then transmitted as a signed integer to the SIMATIC PLC INT has no comma and no units, the maximum value is 32767 For a 20 kg scale you may use a resolution of 1 g: Range 0 g to 20000 g For a 40 kg scale you may use only a resolution of 10 g Range 0.00 kg to 40.00 kg The comma is not part of an integer and is only used for the display Æ Choose resolution and comma before parameterization. When the communication is established, follow the procedure below to make the adjustment. Adj.digits 0 and Adj.digits 1: Accept the default values. Adj.weight 1: Enter the value of adjustment (calibration) weight. Characteristic Value: Sensor characteristic aluee. Indicated on sensor. Default value is 2 mV/V. Page 8 of 15 Limit frequency: Low-pass filter (0.05 Hz ~ 5 Hz). If it is set to 5 Hz, the scale will respond quickly to the weight change; if it is set to 0.5 Hz, the scale will “move slowly”. Depth of average value filter: n=2 ~ 255. The average value filter ensures a stable weight value and prevents interference. The weight is measured according to the average value of n weight values. If n = 10, 10 weight values will be used for calculating the average value. The earliest value is discarded every 20 milliseconds and the latest value will be added for the calculation. Critical damping Step response of the digital low-pass filter of 2 Hz Page 9 of 15 Set the weighing range of the scale and the step (resolution) of the scale. Set the weight unit and the decimal point as follows: Standstill time (ms) and Standstill range are used to monitor when the scale stand still. If the weight change is lower than the specified range (standstill value) within the specified period (standstill time), then the scale stands still. Page 10 of 15 Negative and positive zeroing range. This specification can be used to limit the effect of the function and therefore to protect the process. It is given in % of the max weighing range. Zeroing will be rejected if the current gross weight is too high or too low. After setting the parameters, click Send. Page 11 of 15 Ensure that the scale is empty (not loaded) and click Adjustment zero valid (3). Page 12 of 15 Place the adjustment weight on the scale to adjust the range of the scale. Click Adjustment weight 1 valid (4). Calibration is complete. Page 13 of 15 Eventually you may save the calibration data’s into a file Receive all data’s from the SIWAREX CS to the PC During the transmission from the Siwarex CS module to the PC, the following message- window appears: Save the data as a Siwatool CS File: Page 14 of 15 STEP 7 Programming In the HW-Config from STEP 7 select register “FM” then SIWAREX CS module and place it with Drag&Drop into the configuration. Note the I-Address of the module and enter it as input parameter ADDR of the FB41 For the program, see the file” Info_CS_Getting_Started_24_en.pdf" in the part Getting started of the SIWAREX CS configuration package. For detailed programming, see SIWAREX CS Manual. If you have any problems or suggestions regarding the related products or documents, please feel free to contact: Technical support for SIWAREX Tel: +49 721 595 2811 Fax: +49 721 595 2901 E-mail: siwarex.hotline.aud@siemens.com Website: www.siwarex.com Page 15 of 15 Copyright Statement All rights reserved by Siemens AG This document is subject to change without notice. Under no circumstances shall the content of this document be construed as an express or implied promise, guarantee (for any method, product or equipment) or implication by or from Siemens AG. Partial or full replication or translation of this document without written permission from Siemens AG is illegal.
/
本文档为【SIWAREX_CS整定步骤,西门子公司发行】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索