M–3228–SReleased 3/1/95
PVQ 25 Variable Displacement
Piston Pump
PVQ 25-**R-SE * S-20-C*******D-**-S**
Service Data Vickers®
Piston Pumps
����������
���
�
�����
�� ��
�����������������������
�� ������� ��!
"��#��$
�%&��
�
����'(��"��#����
% ���)*�
Spool��$
�%&��
�
�� Compensator S/A kit
NOTE: Compensator S/A shown is for right hand rotation, rotate
180� for left hand rotation.
�� '�
'�
��
&%
�+ ��!��$
�%&��
�
��� '�'����,� ��!
�� �(�����"&�-��+� ��!
�)*����#�
��!��$
�%&��
�
� )*����#�$
�%&��
��� '�'����,� ��!
�� '
(���*&$-
%.
682910 Piston
689402 Shaft (type 1)
not shown
58303 Key (shaft type
1) not shown
682935 Shaft (type 2)
shown
682369 Yoke
� 683415 Retaining ring
� 683416 Retaining ring
� 49758 Bearing
� 85560 Retaining ring
686753 Spring
409999 Seat
409998 Seat
162160 Roll pin
� 682936 Gasket
� 682702 Shaft seal
860889 Housing 427172 (8) Screw
Torque 19-21 Nm (168-186 lb in)
416637 (2) Cover
923938 Shim kit
� 174140 (2) O-ring
682918 (2) Spacer
417381 (2) Bearing S/A
See opposite side for part numbers.
* NOTE: Position gasket with small end
of teardrop hole pointing in direction of
compensator adjusting plug.
NOTE: Using shim, preload to 0,175/0,225 mm (.007/.009
in). Swing yoke under preload to align bearing rollers at
pintle ends. For proper O-ring compression do not install
more than 0,50 mm (0.20 in) total shims under either
cover.
CD** Elect. Dual Range
Compensator --
see Service Drawing I-3255-S
C* Compensator
For compensator, remote control and electrical dual range models.
Model Comp. Kit Spring Body Spool Plug
�C 02-142732 239371 241568 241371 360430
�CM 02-142731 265693 241568 241371 360430
�CG 942480 239371 412890 296234 412940*
�CMG 941353 265693 412890 296234 412940*
CD See Service Drawing I-3255-S
UV 02-318838 (02-160245 UV control seal kit)
* Plug requires 17077 lock wire and 239157 seal.
���* 244956 Gasket
* NOTE: Position gasket with small end of teardrop hole
pointing in direction of compensator adjusting plug.
��� 262331 O-ring
�� 113000 (2) Plug
��� 154126 O-ring
�� 343740 Plug
�� ��
����������������������
�� ��������
���
�
�����
�� ��
�����������������������
��
'''����+���
�� '�
'�
��
&%
�� '�(�����+ ��!
��� 262335 O-ring
�� ���
��� ��!
�� �����(� ��!
�� ��
�������������������������
��� 154127 O-ring
�� 585164 Set screw
(install to 14,5 mm)
�� ('
�
��)/
�-�
0&�0
��12
�� 113000 Plug
�� 433543 Orifice (B type)
116569 Plug (P type)
Torque 1,7-2,3 Nm (15-20 lb in)
�� 500815 Body
568051 Body (metric)
��
'''�
��+�������&��$
�$
�
�� �(���(��
&%
� ��������+ ��!������+$���!
�
� �����'��+ ��!������+$���
�
�� �(������
&%
�� Compensator S/A kit
NOTE: Compensator S/A shown is for right
hand rotation, rotate 180� for left hand rotation.
� 427682 O-ring
185638 Retaining ring
682909 Piston rod
���'(��� �$%���3�$/�
��12
���
�����/�
�+�&%
���'(����+/
��&���&$/
���'(��� ���
%&��
�'
��������� ��
���
��
�)#����
�����-
���'(�
��+ ��!��&$/
��4 ��%�
������
��+ ��!
���'(����+ ��!��&$/
��
& �
�683414 Retaining ring
690156 Valve plate (R)
690158 Valve plate (L)
682912 Seat
682911 Valve
683605 Spring
398071 Plug
568048 Plug (metric)
� 683412 Bearing
� 154129 O-ring
894027 O-ring (metric) 186580 Plug
875897 Plug (metric)
Torque 50-55 Nm
(442-487 lb in)
683402 (2) Pin
(install in housing)
683422 (2) Pin
877220 Valve block (R)
877221 Valve block (L)
875898 Valve block (R metric)
470819 (5) Screw
Torque 22-27 Nm (195-239 lb in)
� Seal Kit 882955
Rotating Group Kit 882954
� Shaft Bearing Kit 882956
Piston & Rod Kit 882957
� Adjustable max. stop control (see I-3255-S)
For satisfactory service of these components, use full flow filtration to provide fluid which meets ISO cleanliness code 18/16/15 <70 bar (1000 psi),
17/15/13 70-207 bar (1000-3000 psi), 16/14/12 207+ bar (3000+ psi) or cleaner. Selections from pressure return, and in-line filter series are recommended.
� 154124 O-ring
154139 O-ring (metric)
� 354574 Adj. Stop Rod
� 197565 Back-up ring
� 262327 O-ring
� 354578 R.H. Adjuster block
354579 L.H. Adjuster block
� 1450 Nut
� 10932 Screw (4 req’d)
Torque 6,8-8 Nm (61-70 lb in)
C**V**** Load Sensing w/Pressure Limiter
For load sensing models.
Load Sense
Model Comp. Kit Spring Spring
�C**V11B 02-142729 239371 581073
�C**V11P 02-142728 239371 581073
�C**VC24B 02-142730 239371 581072
�C**VC24P 02-142727 239371 581072
Note: Body, plug and spool is the same on all
load sense models. Adjustable max. stop feature
see Service Drawing I-3255-S
Pump design number
20 – Design number subject to change.
Installation dimensions remain
unchanged for designs 20–29.
Control type
C** – Pressure compensator.
Standard setting 21 in tens of
bar (max. setting 201 bar).
Range 02–21 in tens of bar.
CM** – Pressure compensator.
Standard setting, 10 in tens of
bar (max. setting 103 bar).
Range 02–10 in tens of bar
(350–1500 psi).
C**V**B – Pressure compensator C**, as
above with load sensing.
Standard load sensing setting
is 11 bar (160 psi); range
10–17 bar (150–250 psi); with
bleed-down orifice. Example:
C21V11B indicates PVQ25
compensator with 207 bar
pressure setting and 11 bar
load-sense differential.
C**V**P – Pressure compensator with
load sensing as C**V**B
above, but with bleed-down
orifice plugged.
C**VC**B – Pressure compensator with
load sensing. Compensator
same as C** above. Standard
load sensing setting is 24 bar
(350 psi), range 17–31 bar
(250–450 psi). With
bleed-down orifice.
3 4 5 876 9 101 2 11
1
2
Series PVQ
P – Inline piston pump
V – Variable volume
Q – Quiet series
Displacement in cc/rev and pressure
ratings
25 – 25,2 cc/rev (1.54 cir), 207 bar
(3000 psi)
Mounting flange specifications
B2 – Flange SAE J744 101-2 (SAE B)
MB – Flange ISO 3019/2-100A2HW
(available with “N” drive shaft only)
Rotation viewed from shaft end
R – Right hand (cw), standard
L – Left hand (ccw), optional
Ports, type and location
SE – SAE O-ring rear port, 1.0625” inlet
& outlet (standard)
Shafts, input
1 – Straight keyed SAE “B” modified,
2.31” long
3 – Splined SAE “B” modified, 13T
16/32 DP major dia. fit
N – Shaft end ISO 3019/2 E25N (available
with “MB” mount only)
Seals
S – Buna N, standard
3
4
5
6
7
8
9
11
10
C**VC**P – Pressure compensator with
load sensing. Same as
C**VC**B above, but with
bleed-down orifice plugged.
CG – Pressure compensator
modified for hydraulic remote
control.
CD** – Electric dual range
compensator. PVQ25: CD21
is standard 207 bar setting of
high range (24–207 bar). Unit
requires low range to be set
by customer (20–100 bar).
UV – Unloading Valve for
accumulator circuits.
Control option
Blank – Without adjustable maximum
displacement stop (standard)
D – Adjustable maximum displacement
stop (optional)
Control design
10 – C** and CM**
11 – C**D and CM**D
12 – C**V(C)**B and C**V(C)**P
20 – CD**, CG, and UV
Special suffixes
S2 – Shaft up mounting
S3 – British Standard Parallel Threads
Counterbore Ports (ISO R288 threads).
Contact Vickers for available
configurations.
S9 – Special CG compensator for use with
electronically modulated relief valves
12
12
Form No. 00-000 Copyright Eaton Corporation, 0000
All rights reserved.
Printed in U.S.A
Eaton Hydraulics
15151 Highway 5
Eden Prairie, MN 55344
Telephone: 612 937-7254
Fax: 612 937-7130
www.eatonhydraulics.com
46 New Lane, Havant
Hampshire PO9 2NB
England
Telephone: (44) 170-548-6451